1SDA071221R1 ABB E4.2V 4000 Ekip Dip LI 3p FHR Air Circuit Breaker

1SDA071221R1 ABB E4.2V 4000 Ekip Dip LI 3p FHR Air Circuit Breaker

ABB 1SDA071221R1 is a SACE Emax 2 E4.2V 4000 A fixed three-pole air circuit breaker with rear horizontal terminals, an Ekip Dip LI electronic trip unit, a 150 kA breaking-performance rating and a 100 kA short-time withstand rating.

SKU: 1SDA071221R1MPN: 1SDA071221R1
Price
List Price £27,538.85 ex VAT
Your Price (ex VAT) Save 25%
£20,654.14 25% OFF
You save £6,884.71 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £20,654.14
Trade pricing is personalised to your account

Manufacturer Lead Time

£20,654.14

Why Choose the ABB E4.2V 4000 Ekip Dip LI 3p FHR Air Circuit Breaker?

The ABB E4.2V 4000 Ekip Dip LI 3p FHR, order code 1SDA071221R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage power distribution systems. Rated at 4000 A, this three-pole fixed circuit breaker combines ABB's E4.2V high-breaking-capacity frame with an Ekip Dip LI electronic trip unit.

The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection, providing dependable electronic protection for high-current feeders and main distribution circuits. The LI configuration is particularly suitable where straightforward overload and instantaneous fault protection is required without short-time or integrated earth-fault protection functions.

This configuration is a fixed three-pole breaker with rear horizontal (HR) terminals. ABB identifies the E4.2V 4000 configuration with a 150 kA breaking-performance rating and 100 kA short-time withstand rating, providing substantial fault-handling capability for high-current industrial and critical power installations.

Key Advantages

  • High-capacity 4000 A SACE Emax 2 air circuit breaker for major low-voltage distribution circuits.
  • Ekip Dip LI electronic trip unit provides dependable overload and instantaneous short-circuit protection.
  • High-performance E4.2V frame for installations with substantial prospective fault currents.
  • 150 kA breaking-performance rating for demanding low-voltage applications.
  • 100 kA short-time withstand rating supports robust high-current distribution architectures.
  • LI protection provides long-time overload and instantaneous short-circuit protection without unnecessary additional functions.
  • Three-pole fixed configuration for permanent switchboard installation.
  • Rear horizontal terminals support integration with switchboard busbars and power conductors.

Key Features

  • ABB SACE Emax 2 E4.2V frame.
  • 4000 A rated current.
  • Three-pole configuration.
  • Fixed mounting version.
  • Ekip Dip LI electronic release.
  • Long-time overload (L) and instantaneous short-circuit (I) protection.
  • 150 kA breaking-performance rating.
  • 100 kA short-time withstand rating.
  • Rear horizontal (HR) main terminals.
  • Designed for high-current low-voltage power distribution and protection.
  • Part of ABB's modular SACE Emax 2 air circuit breaker platform.
  • Suitable for main incomers, transformer secondaries and major distribution feeders.

High-Performance Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 provide protection, switching and isolation for major low-voltage electrical circuits. The E4.2V frame combines a substantial 4000 A current rating with a 150 kA breaking-performance rating and 100 kA short-time withstand rating, making it particularly suitable for installations where very high prospective fault currents must be managed safely.

The Ekip Dip LI trip unit provides electronic long-time overload and instantaneous short-circuit protection. Long-time protection responds to sustained overcurrent conditions that could otherwise cause excessive thermal stress, while instantaneous protection provides rapid operation during severe short-circuit faults, helping protect conductors, switchgear and other equipment within a correctly coordinated electrical system.

Typical Applications

  • High-current industrial low-voltage switchboards.
  • Main incomer and 4000 A feeder protection.
  • Transformer secondary distribution systems.
  • Manufacturing and process-industry electrical installations.
  • Commercial and infrastructure power distribution.
  • Data centres and critical electrical infrastructure.
  • Utility and generator-fed distribution circuits.
  • Installations requiring high breaking performance with LI electronic protection.

Technical Specifications

Series SACE Emax 2
Frame E4.2V
ABB order code 1SDA071221R1
EAN / GTIN 8015644750718
Product type Air circuit breaker
Rated current 4000 A
Number of poles 3
Trip unit Ekip Dip LI
Release type Electronic
Protection functions L and I
Long-time overload protection Yes
Instantaneous short-circuit protection Yes
Integrated short-time protection No
Integrated earth-fault protection No
Breaking-performance rating 150 kA
Short-time withstand rating 100 kA
Installation Fixed
Terminal configuration Rear horizontal (HR)
Product net weight 63 kg
Country of origin Italy
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071221R1?

The ABB 1SDA071221R1 is a SACE Emax 2 E4.2V fixed three-pole air circuit breaker rated at 4000 A and equipped with an Ekip Dip LI electronic trip unit.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection.

What is the current rating of the ABB E4.2V 1SDA071221R1?

The ABB 1SDA071221R1 is a 4000 A E4.2V air circuit breaker designed for high-current low-voltage distribution systems.

What is the breaking-performance rating of the ABB E4.2V 4000?

ABB specifies a 150 kA breaking-performance rating for the E4.2V 4000 configuration, providing high fault-interruption capability for demanding electrical installations.

What is the short-time withstand rating of the E4.2V 4000?

The E4.2V 4000 configuration has a specified 100 kA short-time withstand rating, supporting demanding high-current distribution applications.

Does the ABB 1SDA071221R1 provide earth-fault protection?

No. The supplied Ekip Dip LI configuration provides long-time overload and instantaneous short-circuit protection; an integrated G earth-fault protection function is not included in this LI version.

Is the ABB 1SDA071221R1 fixed or withdrawable?

The 1SDA071221R1 is a fixed-version circuit breaker intended for permanent installation within a low-voltage switchboard.

What does FHR mean for the ABB 1SDA071221R1?

This configuration is a fixed circuit breaker with rear horizontal terminals, providing rear-facing main connections suitable for integration with switchboard busbars and conductors.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine high-current switching and protection with electronic trip technology and high short-circuit performance for demanding industrial, commercial, infrastructure and critical power distribution applications worldwide.