ABB 1SDA071217R1 Emax 2 E4.2H 4000 Ekip G Touch LSIG three-pole fixed air circuit breaker with a 4000 A rated uninterrupted current, 690 V AC operational voltage, 100 kA breaking capacity at 400–440 V AC and advanced generator-oriented LSIG electronic protection.
£20,639.54
The ABB E4.2H 4000 Ekip G Touch LSIG 3p FHR, order code 1SDA071217R1, is a high-current air circuit breaker (ACB) designed for advanced protection, switching and isolation in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 range, it combines a 4000 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit for sophisticated generator, transformer and installation protection.
The E4.2H performance level provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC. Its Ekip G Touch LSIG electronic release provides long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection, delivering comprehensive protection for high-capacity electrical networks.
With a rated operational voltage of 690 V AC, three-pole construction and fixed installation with rear flat horizontal terminals, the 1SDA071217R1 is engineered for integration into high-capacity low-voltage switchboards. Its 85 kA rated short-time withstand current for 1 s, advanced generator-oriented Ekip G protection platform and high breaking capacity make it particularly suitable for demanding power generation and distribution applications.
The ABB Emax 2 E4.2H combines high-current switching capability with the generator-oriented Ekip G Touch LSIG protection platform. Its 4000 A current rating, 100 kA breaking capacity at 400–440 V AC and high short-time withstand capability make it suitable for protecting switchboards, generators, transformers, busbars, cables and other critical components in substantial low-voltage power systems.
The LSIG protection profile combines long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection. Short-time protection assists coordination between upstream and downstream protective devices, while integrated earth-fault protection adds another layer of fault detection. The Ekip G Touch platform makes this configuration particularly relevant where generator and installation protection functions are required alongside comprehensive circuit-breaker protection.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Series | SACE Emax 2 E4.2 |
| Performance level | H |
| Order code / SKU | 1SDA071217R1 |
| EAN / GTIN | 8015644750671 |
| Product type | Air circuit breaker (ACB) |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip G Touch LSIG |
| Release type | Electronic (EL) |
| Protection functions | Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth fault (G) |
| Overload protection adjustment range | 1600–4000 A |
| Short-time protection adjustment range | 2400–40000 A |
| Instantaneous protection adjustment range | 6000–60000 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 / 415 / 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 / 525 / 690 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 85 kA |
| Rated short-time withstand current (Icw), 3 s | 75 kA |
| Installation | Fixed |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Open/closed position indication | Yes |
| Integrated earth-fault protection | Yes |
| Motor operator | Optional |
| Degree of protection | IP30 |
| Suitable for IT networks | Yes, up to 690 V |
| Power loss | 465 W |
| Electrical durability at Ue ≤ 440 V | 5000 cycles |
| Electrical durability at Ue 500–690 V | 4000 cycles |
| Mechanical durability | 15000 cycles |
| Product net width | 384 mm |
| Product net height | 371 mm |
| Product net depth | 270 mm |
| Product net weight | 81 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071217R1 is an Emax 2 air circuit breaker designed for advanced generator, transformer and installation protection as well as switching and isolation in high-current low-voltage power systems.
The breaker has a rated uninterrupted current of 4000 A, making it suitable for high-capacity switchboards, generator systems, main incomers and large electrical feeders.
The E4.2H provides a rated ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC. Its rated short-time withstand current is 85 kA for 1 s and 75 kA for 3 s.
The Ekip G Touch LSIG electronic trip unit provides long-time overload, selective short-time short-circuit, instantaneous short-circuit and earth-fault protection, with generator-oriented functionality for demanding power generation and distribution applications.
The 1SDA071217R1 is a fixed three-pole air circuit breaker with rear flat horizontal main terminals and bolted main-circuit connections for integration into low-voltage switchboards and power distribution assemblies.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced Ekip electronic protection technology, providing dependable protection and control for generators, transformers and high-current low-voltage power distribution systems.