1SDA071215R1 ABB E4.2H 4000 Ekip Touch LSI 3p F HR Air Circuit Breaker

1SDA071215R1 ABB E4.2H 4000 Ekip Touch LSI 3p F HR Air Circuit Breaker

ABB 1SDA071215R1 Emax 2 E4.2H 4000 air circuit breaker, a 4000 A three-pole fixed ACB with Ekip Touch LSI electronic protection, 690 V AC rated operational voltage and up to 100 kA short-circuit breaking capacity.

SKU: 1SDA071215R1MPN: 1SDA071215R1
Price
List Price £23,446.03 ex VAT
Your Price (ex VAT) Save 25%
£17,584.52 25% OFF
You save £5,861.51 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,584.52
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,584.52

Why Choose the ABB E4.2H 4000 Ekip Touch LSI 3p F HR Air Circuit Breaker?

The ABB E4.2H 4000 Ekip Touch LSI 3p F HR, order code 1SDA071215R1, is a high-performance Emax 2 air circuit breaker (ACB) designed for protection, switching and isolation in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 series, it combines a 4000 A rated uninterrupted current with high short-circuit performance for industrial, infrastructure and critical power applications.

This fixed three-pole circuit breaker incorporates the Ekip Touch LSI solid-state electronic trip unit, providing adjustable long-time overload, selective short-time and instantaneous short-circuit protection. The Ekip Touch platform provides an intuitive touchscreen interface for configuring protection parameters and accessing breaker information, supporting effective selectivity and coordination within sophisticated electrical distribution systems.

With a rated uninterrupted current of 4000 A and a rated operational voltage of 690 V AC, the E4.2H provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC. Its fixed three-pole construction, rear flat horizontal terminals and high short-time withstand capability make it suitable for integration into high-current low-voltage switchboards.

Key Advantages

  • High-current 4000 A Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 100 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 85 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 85 kA short-time withstand current for 1 s supports selective protection systems.
  • Advanced Ekip Touch LSI electronic trip unit for overload and short-circuit protection.
  • Long-time, selective short-time and instantaneous protection functions.
  • Touchscreen interface for intuitive electronic protection configuration.
  • Fixed three-pole construction with rear flat horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2H series.
  • 4000 A rated uninterrupted current.
  • Three-pole fixed configuration.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100 kA Icu at 400 / 415 / 440 V AC.
  • 85 kA Icu at 500 / 525 / 690 V AC.
  • 100% Ics-to-Icu ratio.
  • 85 kA Icw for 1 s and 75 kA for 3 s.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload, selective short-time and instantaneous short-circuit protection.
  • Overload protection adjustable from 1600–4000 A.
  • Short-time delayed short-circuit protection adjustable from 2400–40000 A.
  • Instantaneous short-circuit protection adjustable from 6000–60000 A.
  • Rear flat horizontal terminal connections.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.
  • Suitable for IT networks up to 690 V.

Advanced LSI Protection for High-Current Power Distribution

Air circuit breakers such as the ABB Emax 2 E4.2H protect high-current low-voltage distribution systems against overload and short-circuit conditions while providing controlled switching and isolation. With a 4000 A current rating, 100 kA breaking capacity at 400–440 V AC and substantial short-time withstand capability, this E4.2H configuration is suitable for main distribution points and other critical high-current sections of electrical installations.

The Ekip Touch LSI electronic trip unit combines adjustable long-time overload protection with selective short-time and instantaneous short-circuit protection. Its touchscreen interface simplifies configuration, while adjustable protection thresholds allow the breaker to be coordinated with upstream and downstream protective devices to improve selectivity and continuity of supply.

Typical Applications

  • Main low-voltage switchboards and power distribution boards.
  • High-current industrial electrical distribution systems.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Large commercial and infrastructure installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Electrical distribution systems requiring selective electronic overload and short-circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071215R1
EAN 8015644750657
Product type Air circuit breaker (ACB)
Frame E4.2
Short-circuit performance level H
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Rated ultimate short-circuit breaking capacity (Icu) 100 kA at 400 / 415 / 440 V AC
Rated service short-circuit breaking capacity (Ics) 100 kA at 380–440 V AC; 85 kA at 500–690 V AC
Rated service short-circuit breaking capacity 100% of Icu
Rated short-time withstand current (Icw) 85 kA for 1 s; 75 kA for 3 s
Number of poles 3
Current type AC
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time overload, selective short-time and instantaneous short circuit
Overload release adjustment 1600–4000 A
Short-time delayed short-circuit adjustment 2400–40000 A
Instantaneous short-circuit adjustment 6000–60000 A
Integrated earth-fault protection No
Mounting type Fixed
Terminal connection Rear flat horizontal
Terminal type Bolt
Connecting capacity 4000 mm²
Recommended main circuit screw M12
Tightening torque 70 N·m
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Motor drive integrated No
Motor drive optional Yes
Power loss 465 W
Mechanical durability 15,000 cycles
Electrical durability 5,000 cycles at Ue ≤ 440 V; 4,000 cycles at Ue 500–690 V
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071215R1 used for?

The ABB 1SDA071215R1 is an Emax 2 air circuit breaker designed for switching and protection of high-current low-voltage electrical distribution systems, including main incomers, transformer secondaries and high-current feeders requiring electronic LSI protection.

What is the current rating of the ABB E4.2H 4000?

The circuit breaker has a rated uninterrupted current of 4000 A, making it suitable for demanding industrial, infrastructure and critical power distribution systems.

What is the breaking capacity of the ABB 1SDA071215R1?

The E4.2H 4000 provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 500–690 V AC, with a rated short-time withstand current of 85 kA for 1 s.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides adjustable long-time overload, selective short-time and instantaneous short-circuit protection, with a touchscreen interface for configuration and access to breaker information.

Is the ABB 1SDA071215R1 fixed or withdrawable?

The 1SDA071215R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current capability, strong short-circuit performance and advanced Ekip electronic protection for demanding industrial, infrastructure and critical low-voltage power distribution applications.