1SDA071205R1 ABB E4.2S 4000 Ekip Touch LSI 3p FHR Air Circuit Breaker

1SDA071205R1 ABB E4.2S 4000 Ekip Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA071205R1 SACE Emax 2 E4.2S fixed three-pole air circuit breaker with Ekip Touch LSI electronic protection, 4000 A rated current, 690 V AC operational voltage and 85 kA breaking capacity at 400–440 V AC.

SKU: 1SDA071205R1MPN: 1SDA071205R1
Price
List Price £22,276.67 ex VAT
Your Price (ex VAT) Save 25%
£16,707.50 25% OFF
You save £5,569.17 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £16,707.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£16,707.50

Why Choose the ABB E4.2S 4000 Ekip Touch LSI 3p FHR Air Circuit Breaker?

The ABB E4.2S 4000 Ekip Touch LSI 3p FHR, order code 1SDA071205R1, is a high-current SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. This fixed three-pole E4.2 breaker combines a 4000 A rated current with ABB's advanced Ekip Touch LSI solid-state electronic trip unit.

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its touchscreen interface provides convenient access to protection settings and operating information, while the adjustable short-time function supports selective coordination between upstream and downstream protective devices.

The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, a rated short-time withstand current of 66 kA and rear horizontal terminals, the 1SDA071205R1 is engineered for high-capacity industrial, infrastructure and critical-power switchboards.

Key Advantages

  • High-current ABB SACE Emax 2 E4.2S air circuit breaker.
  • 4000 A rated current for major low-voltage distribution systems.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA breaking capacity at 500–690 V AC.
  • 66 kA rated short-time withstand capability for demanding distribution networks.
  • Advanced Ekip Touch LSI electronic trip unit.
  • Long-time, short-time and instantaneous protection supports coordinated system protection.
  • Touchscreen interface simplifies protection configuration and supervision.
  • Fixed three-pole construction with rear horizontal terminals for permanent switchboard integration.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 4000 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Overload protection adjustable from 0.4–1 × In.
  • Short-time protection adjustable from 0.6–10 × In.
  • Instantaneous protection adjustable from 1.5–15 × In.
  • Rated operational voltage of 690 V AC.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • Rear horizontal main terminals.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism.

Advanced LSI Protection for 4000 A Power Distribution

The ABB SACE Emax 2 E4.2S is engineered for major low-voltage distribution points where very high continuous currents and substantial prospective fault levels demand robust interruption and withstand performance. Its combination of a 4000 A current rating, 85 kA breaking capacity at 400–440 V AC and 66 kA short-time withstand capability makes it a strong choice for protecting high-capacity switchboards, busbars, transformers and major feeders.

The Ekip Touch LSI trip unit adds adjustable short-time protection between the long-time overload and instantaneous functions. This enables selective coordination with downstream protective devices, helping isolate the circuit affected by a fault while maintaining continuity elsewhere in the distribution system where the overall protection design permits.

Typical Applications

  • High-current low-voltage main switchboards.
  • Industrial power distribution systems.
  • Main incomer protection.
  • High-current feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres and substations.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Heavy-industry electrical distribution.
  • Systems requiring selective short-circuit coordination.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2
ABB order code 1SDA071205R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level S
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Integrated earth-fault protection No
Overload protection adjustment 0.4–1 × In
Overload release setting range 1600–4000 A
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Instantaneous short-circuit setting range 6000–60,000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) at 400–440 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 66 kA
Rated short-time withstand current (Icw) 66 kA
Main terminal position Rear
Terminal orientation Horizontal
Main-circuit connection Bolt connection
Connecting capacity 4000 mm²
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Degree of protection IP30
Control element Push button
Complete device with protection unit Yes
Motor drive integrated No
Motor drive optional Yes
Integrated undervoltage release No
DIN rail mounting No
Power loss 465 W
Electrical durability at Ue ≤ 440 V 5000 cycles
Electrical durability at 500–690 V 4000 cycles
Electrical operating frequency 20 cycles per hour
Mechanical durability 15,000 cycles
Mechanical operating frequency 60 cycles per hour
EAN / GTIN 8015644750558
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071205R1?

The ABB 1SDA071205R1 is a SACE Emax 2 E4.2S fixed three-pole air circuit breaker rated at 4000 A and equipped with an Ekip Touch LSI solid-state electronic trip unit.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. This LSI configuration does not include integrated earth-fault protection.

What is the breaking capacity of the ABB E4.2S 4000?

The E4.2S 4000 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

Why choose LSI protection instead of LI protection?

LSI protection adds an adjustable short-time delayed short-circuit function between the long-time and instantaneous stages, providing greater flexibility for selective coordination with downstream protective devices.

Where is the ABB E4.2S 4000 Ekip Touch LSI typically used?

It is designed for high-current low-voltage distribution applications including industrial main switchboards, high-capacity incomers and feeders, transformer secondary systems, infrastructure installations, critical-power networks and OEM switchgear assemblies.