Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071204R1 SACE Emax 2 E4.2S fixed three-pole air circuit breaker with Ekip Touch LI electronic protection, 4000 A rated current, 690 V AC rating and 85 kA breaking capacity at 400–440 V AC.
£16,400.56
The ABB E4.2S 4000 Ekip Touch LI 3p FHR, order code 1SDA071204R1, is a high-current SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. This fixed three-pole E4.2 breaker combines a 4000 A rated uninterrupted current with ABB's advanced Ekip Touch LI solid-state electronic trip unit.
The Ekip Touch LI release provides adjustable long-time overload and instantaneous short-circuit protection. Its touchscreen-based electronic platform provides an intuitive interface for configuring and supervising protection settings, while the LI protection profile offers a focused solution where overload and rapid high-level short-circuit protection are required without short-time delayed or integrated earth-fault protection.
The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a rated short-time withstand current of 66 kA. With a 690 V AC rated voltage, fixed three-pole construction and rear flat horizontal terminals, the 1SDA071204R1 is engineered for high-capacity industrial, infrastructure and critical-power switchboards.
The ABB SACE Emax 2 E4.2S is engineered for major low-voltage distribution points where very high continuous currents and substantial prospective fault levels require robust interruption and withstand performance. Its combination of a 4000 A current rating, 85 kA breaking capacity at 400–440 V AC and 66 kA short-time withstand capability provides dependable protection for high-capacity switchboards, busbars, transformers and major outgoing circuits.
The Ekip Touch LI trip unit combines adjustable long-time overload protection with high-speed instantaneous short-circuit protection. This LI configuration is particularly suited to installations where straightforward electronic overload and short-circuit protection is required without short-time delayed or integrated earth-fault functions, while the Ekip Touch platform provides a modern interface for protection configuration and supervision.
| Series | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA071204R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Frame / sub-type | E4.2 |
| Short-circuit performance level | S |
| Rated uninterrupted current (Iu) | 4000 A |
| Current type | AC |
| Number of poles | 3 |
| Installation | Fixed |
| Trip unit | Ekip Touch LI |
| Release type | Solid-state electronic |
| Protection functions | Long-time and instantaneous (LI) |
| Short-time delayed protection | No |
| Integrated earth-fault protection | No |
| Overload release setting range | 1600–4000 A |
| Instantaneous short-circuit release setting range | 6000–60,000 A |
| Rated voltage | 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 66 kA |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Terminal type | Bolt |
| Recommended main-circuit screw | M12 |
| Tightening torque | 70 N·m |
| Auxiliary contacts | 4 change-over contacts |
| Position indication | Circuit breaker open / closed |
| Complete device with protection unit | Yes |
| Motor drive integrated | No |
| Motor drive optional | Yes |
| Integrated undervoltage release | No |
| DIN rail mounting | No |
| Suitable for IT networks | Yes, up to 690 V |
| Electrical durability | 5000 cycles at Ue ≤ 440 V; 4000 cycles at 500–690 V |
| Electrical operating frequency | 20 cycles per hour |
| Mechanical durability | 15,000 cycles |
| Product net width | 384 mm |
| Product net height | 371 mm |
| Product net depth | 270 mm |
| EAN / GTIN | 8015644750541 |
| Standard | IEC |
The ABB 1SDA071204R1 is a SACE Emax 2 E4.2S fixed three-pole air circuit breaker rated at 4000 A and equipped with an Ekip Touch LI solid-state electronic trip unit.
The Ekip Touch LI release provides long-time overload and instantaneous short-circuit protection. This LI configuration does not include short-time delayed or integrated earth-fault protection.
The E4.2S 4000 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.
The overload release is adjustable from 1600–4000 A, while the instantaneous short-circuit release is adjustable from 6000–60,000 A.
It is designed for high-current low-voltage distribution applications including industrial main switchboards, high-capacity incomers and feeders, transformer secondary systems, infrastructure installations, critical-power networks and OEM switchgear assemblies.
ABB SACE Emax 2 air circuit breakers combine high-current switching, substantial short-circuit performance and advanced electronic protection for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.