ABB 1SDA071203R1 Emax 2 E4.2S 4000 air circuit breaker, a 4000 A three-pole fixed ACB with Ekip Dip LSIG electronic protection, 690 V AC rated operational voltage and up to 85 kA short-circuit breaking capacity.
£17,131.42
The ABB E4.2S 4000 Ekip Dip LSIG 3p F HR, order code 1SDA071203R1, is a high-current Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 series, it combines a 4000 A rated uninterrupted current with substantial short-circuit performance for industrial, infrastructure and critical power installations.
This fixed three-pole circuit breaker incorporates the Ekip Dip LSIG solid-state electronic trip unit, providing long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection. The Ekip Dip platform provides straightforward local adjustment of protection settings, supporting effective selectivity and coordination throughout high-current electrical distribution systems.
With a rated uninterrupted current of 4000 A and a rated operational voltage of 690 V AC, the E4.2S provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. Its fixed three-pole construction and rear flat horizontal terminals provide a robust solution for integration into high-current low-voltage switchboards.
Air circuit breakers such as the ABB Emax 2 E4.2S protect high-current low-voltage distribution systems against overload, short-circuit and earth-fault conditions while providing controlled switching and isolation. With a 4000 A current rating and substantial fault-interruption capability, this E4.2S configuration is well suited to main distribution points, transformer secondaries and other high-current sections of electrical installations.
The Ekip Dip LSIG electronic trip unit combines long-time overload, selective short-time and instantaneous short-circuit protection with integrated earth-fault protection. Adjustable protection thresholds support coordination between upstream and downstream protective devices, while the Ekip Dip interface provides a straightforward method of configuring essential protection settings directly at the circuit breaker.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA071203R1 |
| EAN | 8015644750534 |
| Product type | Air circuit breaker (ACB) |
| Frame | E4.2 |
| Short-circuit performance level | S |
| Rated current (In) | 4000 A |
| Rated uninterrupted current (Iu) | 4000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 400 / 415 / 440 V AC |
| Rated service short-circuit breaking capacity (Ics) | 85 kA at 380–440 V AC; 66 kA at 500–690 V AC |
| Rated service short-circuit breaking capacity | 100% of Icu |
| Rated short-time withstand current (Icw) | 66 kA for 1 s; 66 kA for 3 s |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip Dip LSIG |
| Release type | Solid-state electronic |
| Protection functions | Long-time overload, selective short-time, instantaneous short circuit and earth fault |
| Overload release adjustment | 1600–4000 A |
| Short-time delayed short-circuit adjustment | 2400–40000 A |
| Integrated earth-fault protection | Yes |
| Mounting type | Fixed |
| Terminal connection | Rear flat horizontal |
| Terminal type | Bolt |
| Connecting capacity | 4000 mm² |
| Recommended main circuit screw | M12 |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 465 W |
| Mechanical durability | 15,000 cycles |
| Electrical durability | 5,000 cycles at Ue ≤ 440 V; 4,000 cycles at Ue 500–690 V |
| Dimensions (H × W × D) | 371 × 384 × 270 mm |
| Net weight | 56 kg |
| Suitable for IT networks | Yes, up to 690 V |
| Standard | IEC |
The ABB 1SDA071203R1 is an Emax 2 air circuit breaker designed for switching and protection of high-current low-voltage electrical distribution systems, including main incomers, transformer secondaries and high-current feeders requiring LSIG protection.
The circuit breaker has a rated uninterrupted current of 4000 A, making it suitable for high-current industrial, infrastructure and critical power distribution systems.
The E4.2S 4000 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, with a rated short-time withstand current of 66 kA for 1 s and 3 s.
The Ekip Dip LSIG electronic trip unit provides long-time overload, selective short-time, instantaneous short-circuit and earth-fault protection for comprehensive protection of low-voltage electrical distribution systems.
The 1SDA071203R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine high-current capability, dependable short-circuit performance and comprehensive electronic LSIG protection for demanding industrial, infrastructure and critical low-voltage power distribution applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.