1SDA071200R1 ABB E4.2N 4000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker

1SDA071200R1 ABB E4.2N 4000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA071200R1 E4.2N 4000 Ekip G Hi-Touch LSIG is a fixed three-pole 4000 A SACE Emax 2 air circuit breaker with rear horizontal terminals, 66 kA breaking capacity at 400–690 V AC and advanced electronic LSIG generator protection.

SKU: 1SDA071200R1MPN: 1SDA071200R1
Price
List Price £24,225.61 ex VAT
Your Price (ex VAT) Save 25%
£18,169.21 25% OFF
You save £6,056.40 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £18,169.21
Trade pricing is personalised to your account

Manufacturer Lead Time

£18,169.21

Why Choose the ABB E4.2N 4000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E4.2N 4000 Ekip G Hi-Touch LSIG 3p F HR, order code 1SDA071200R1, is a high-performance 4000 A three-pole air circuit breaker (ACB) designed for advanced generator and low-voltage power distribution protection. Part of the ABB SACE Emax 2 series, it combines the E4.2N performance class with fixed mounting, rear horizontal terminals and the sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The E4.2N 4000 provides an ultimate short-circuit breaking capacity of 66 kA at 440 V AC and a rated short-time withstand current of 66 kA for 1 s. Its 4000 A continuous-current capability makes it suitable for substantial generator, industrial and infrastructure distribution systems requiring dependable high-current switching and fault protection.

Protection is provided by the Ekip G Hi-Touch LSIG electronic release, combining long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection with advanced generator-oriented protection, measurement and monitoring capabilities. The breaker is supplied in a fixed three-pole configuration with rear flat horizontal terminals for integration into suitable low-voltage switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for generator and power distribution applications.
  • 4000 A rated uninterrupted current for demanding high-current systems.
  • Ekip G Hi-Touch LSIG electronic trip unit with advanced generator protection functionality.
  • Comprehensive long-time, short-time, instantaneous and earth-fault protection.
  • 66 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 66 kA rated short-time withstand current for 1 s.
  • Rated for operation up to 690 V AC.
  • Fixed three-pole construction with rear horizontal terminals.

Key Features

  • ABB SACE Emax 2 E4.2N series.
  • 4000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Rear flat horizontal main terminals.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • 66 kA Icu at 400–690 V AC.
  • 66 kA Ics at 400–690 V AC.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.

Advanced Generator and Power Distribution Protection

ABB SACE Emax 2 air circuit breakers provide switching, isolation and electronic protection for high-current low-voltage networks. The E4.2N 4000 combines a 4000 A continuous-current rating with 66 kA breaking capacity at 400–690 V AC and 66 kA one-second short-time withstand capability, providing robust performance for substantial generator and distribution installations.

The Ekip G Hi-Touch LSIG release combines comprehensive overload, delayed short-circuit, instantaneous short-circuit and earth-fault protection with advanced functionality intended for generator applications. Its protection and monitoring capabilities support selective coordination and effective management of complex low-voltage networks while helping maintain continuity of supply to unaffected circuits.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage distribution switchboards.
  • High-current industrial power distribution systems.
  • Manufacturing and process plants.
  • Critical infrastructure and standby power systems.
  • Transformer and generator-fed distribution networks.
  • Utility and high-current switchgear assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA071200R1
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw, 1 s) 66 kA
Rated short-time withstand current (Icw, 3 s) 50 kA
Number of poles 3
Current type AC
Mounting Fixed
Main terminal arrangement Rear flat horizontal
Main circuit connection Bolt connection
Recommended connection screw M12
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault
Short-circuit performance level N
Suitable for IT networks Yes, up to 690 V
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071200R1 used for?

The ABB 1SDA071200R1 is a 4000 A air circuit breaker designed for advanced generator protection and high-current low-voltage power distribution systems.

What protection unit is fitted to the ABB 1SDA071200R1?

The breaker is fitted with an ABB Ekip G Hi-Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection together with advanced functionality for generator applications.

What is the rated current of the ABB E4.2N 1SDA071200R1?

The breaker has a rated uninterrupted current of 4000 A.

Is the ABB 1SDA071200R1 fixed or withdrawable?

The 1SDA071200R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal main terminals.

What is the breaking capacity of the ABB E4.2N 4000?

The E4.2N 4000 provides an ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC and a rated short-time withstand current of 66 kA for 1 s.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-specific functionality and dependable short-circuit performance for switching, protection and monitoring in demanding low-voltage power distribution systems.