1SDA071197R1 ABB E4.2N 4000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

1SDA071197R1 ABB E4.2N 4000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA071197R1 E4.2N 4000 Ekip G Touch LSIG 3p F HR is a fixed three-pole 4000 A SACE Emax 2 air circuit breaker with 66 kA short-circuit breaking capacity, generator-oriented Ekip G Touch LSIG electronic protection and integrated earth-fault protection.

SKU: 1SDA071197R1MPN: 1SDA071197R1
Price
List Price £23,329.12 ex VAT
Your Price (ex VAT) Save 25%
£17,496.84 25% OFF
You save £5,832.28 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £17,496.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£17,496.84

Why Choose the ABB E4.2N 4000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E4.2N 4000 Ekip G Touch LSIG 3p F HR, order code 1SDA071197R1, is a high-performance air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 4000 A rated current with the Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, together with functionality intended for generator applications. Its configurable electronic protection platform supports effective coordination, supervision and protection of generators and high-current distribution circuits.

The E4.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC, with a service breaking capacity equal to 100% of Icu and a short-time withstand current of 66 kA for 1 s. This version features a fixed three-pole construction with rear horizontal terminals and four auxiliary change-over contacts.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for generator and power distribution applications.
  • 4000 A rated current for substantial high-current electrical installations.
  • 66 kA ultimate short-circuit breaking capacity across 400–690 V AC.
  • 66 kA short-time withstand current for 1 s for effective protection coordination.
  • Advanced Ekip G Touch LSIG electronic trip unit with generator-oriented protection functionality.
  • Integrated earth-fault protection alongside overload and short-circuit protection.
  • 100% service short-circuit breaking capacity relative to Icu.
  • Fixed three-pole construction with rear horizontal terminals.

Key Features

  • ABB SACE Emax 2 E4.2N series.
  • 4000 A rated current.
  • Three-pole fixed air circuit breaker.
  • Ekip G Touch LSIG electronic protection release.
  • Long-time overload (L), short-time delayed (S), instantaneous short-circuit (I) and earth-fault (G) protection.
  • Generator-oriented electronic protection functionality.
  • 66 kA Icu at 400–690 V AC.
  • 66 kA Icw for 1 s and 50 kA Icw for 3 s.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Rear horizontal main circuit connections.
  • Four auxiliary change-over contacts with open/closed position indication.

Advanced Generator and Power Distribution Protection

Generator circuits can require specialised protection because their operating and fault characteristics differ from conventional utility-fed distribution systems. The ABB E4.2N 4000 with Ekip G Touch combines a substantial 4000 A current capability with generator-oriented electronic protection, making it suitable for generator switchboards, standby power systems and industrial generation installations.

The Ekip G Touch LSIG release combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection with configurable functionality for generator applications. Together with the E4.2N frame's 66 kA breaking capacity and short-time withstand capability, this supports selective coordination, dependable fault isolation and protection of generators, conductors, switchgear and connected equipment.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency generation systems.
  • Industrial generation and power distribution installations.
  • Main low-voltage electrical distribution switchboards.
  • High-current main incomer applications.
  • Systems requiring integrated earth-fault protection.
  • Commercial and infrastructure power systems.
  • Data centres and critical power distribution systems.
  • OEM switchgear and electrical panel building.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame E4.2N
ABB order code / MPN 1SDA071197R1
Product type Air circuit breaker
Rated current (In) 4000 A
Rated uninterrupted current (Iu) 4000 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) 66 kA at 400–690 V AC
Service short-circuit breaking capacity (Ics) 66 kA at 400–690 V AC
Ics relative to Icu 100%
Short-time withstand current (Icw) 66 kA for 1 s; 50 kA for 3 s
Number of poles 3
Current type AC
Trip unit Ekip G Touch LSIG
Release type Electronic
Protection functions LSIG with generator-oriented protection functionality
Overload release adjustment range 1600–4000 A
Short-time delayed short-circuit adjustment range 2400–40000 A
Instantaneous short-circuit adjustment range 6000–60000 A
Earth-fault protection Integrated
Short-circuit performance level N
Installation version Fixed
Main terminal position Rear
Main terminal orientation Rear horizontal
Connecting capacity 4000 mm²
Auxiliary contacts 4 change-over contacts
Open/closed position indication Yes
Integrated undervoltage release No
Integrated motor operator No
Optional motor operator Yes
Suitable for IT networks Yes, up to 690 V
Mechanical durability 15,000 cycles
Electrical durability 5,000 cycles at Ue ≤ 440 V; 4,000 cycles at Ue 500–690 V
Power loss 465 W
Dimensions (W × H × D) 384 × 371 × 270 mm
Standard IEC
Country of origin Italy
EAN / GTIN 8015644750473

Frequently Asked Questions

What is the ABB 1SDA071197R1 used for?

The ABB 1SDA071197R1 is an Emax 2 air circuit breaker designed for generator protection and high-current low-voltage power distribution applications, combining a 4000 A E4.2N breaker with the Ekip G Touch LSIG electronic trip unit.

What is the current rating of the ABB E4.2N 4000?

The circuit breaker has a rated current of 4000 A, making it suitable for substantial generator circuits and high-current low-voltage power distribution systems.

What breaking capacity does the ABB 1SDA071197R1 provide?

The E4.2N 4000 provides an ultimate short-circuit breaking capacity of 66 kA at 400–690 V AC, with a service breaking capacity of 100% of Icu and a short-time withstand current of 66 kA for 1 s.

What protection functions are provided by the Ekip G Touch LSIG trip unit?

The Ekip G Touch LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with functionality intended for generator applications.

Is the ABB 1SDA071197R1 a fixed or withdrawable circuit breaker?

The 1SDA071197R1 is a fixed three-pole air circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards and generator protection assemblies.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are designed for reliable protection, control and monitoring of low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection for demanding industrial, commercial and generator applications.