1SDA071165R1 ABB E4.2H 3200 Ekip Touch LSI 3p FHR Air Circuit Breaker

1SDA071165R1 ABB E4.2H 3200 Ekip Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA071165R1 SACE Emax 2 E4.2H fixed three-pole air circuit breaker with Ekip Touch LSI electronic protection, 3200 A rated current, 690 V AC rating and 100 kA breaking capacity at 440 V AC.

SKU: 1SDA071165R1MPN: 1SDA071165R1
Price
List Price £16,351.83 ex VAT
Your Price (ex VAT) Save 25%
£12,263.87 25% OFF
You save £4,087.96 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,263.87
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,263.87

Why Choose the ABB E4.2H 3200 Ekip Touch LSI 3p FHR Air Circuit Breaker?

The ABB E4.2H 3200 Ekip Touch LSI 3p FHR, order code 1SDA071165R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. This fixed three-pole E4.2 breaker combines a 3200 A rated uninterrupted current with ABB's advanced Ekip Touch LSI solid-state electronic trip unit.

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its adjustable electronic protection functions support selective coordination within complex distribution systems, while the Ekip Touch interface provides an intuitive platform for configuring protection settings and accessing operating information.

The E4.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s. Rated for operation at 690 V AC and supplied with rear horizontal terminals, four change-over auxiliary contacts and open/closed position indication, the 1SDA071165R1 is engineered for high-current industrial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E4.2H air circuit breaker.
  • 3200 A rated uninterrupted current for major low-voltage distribution circuits.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 85 kA rated short-time withstand current for 1 s.
  • Advanced Ekip Touch LSI electronic trip unit.
  • Long-time, short-time and instantaneous protection supports coordinated distribution-system design.
  • Adjustable short-time protection helps achieve selectivity with downstream protective devices.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear horizontal terminals support efficient connection to high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E4.2H series.
  • 3200 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Touch LSI solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Overload release adjustable from 1280–3200 A.
  • Short-time delayed short-circuit release adjustable from 1920–32,000 A.
  • Instantaneous short-circuit release adjustable from 4800–48,000 A.
  • Rated voltage of 690 V AC.
  • 100 kA Icu at 400 V AC.
  • 85 kA Icw for 1 s.
  • Rear horizontal main terminals.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism.

Advanced LSI Protection for High-Current Power Distribution

The ABB SACE Emax 2 E4.2H is engineered for major low-voltage distribution points where high continuous currents and substantial prospective fault levels demand robust interruption and withstand performance. Its combination of a 3200 A rated current, 100 kA breaking capacity at 440 V AC and 85 kA short-time withstand capability provides dependable protection for switchboards, feeders, busbars, transformers and connected equipment.

The Ekip Touch LSI trip unit adds adjustable short-time protection between the long-time overload and instantaneous functions. This allows improved coordination with downstream protective devices, helping isolate the circuit affected by a fault while maintaining continuity elsewhere in the installation where the overall protection design permits.

Typical Applications

  • High-current low-voltage main switchboards.
  • Industrial power distribution systems.
  • Main incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Heavy-industry low-voltage distribution.
  • Systems requiring coordinated short-circuit protection.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E4.2
ABB order code 1SDA071165R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level H
Rated uninterrupted current (Iu) 3200 A
Rated voltage 690 V AC
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Integrated earth-fault protection No
Overload release setting range 1280–3200 A
Short-time delayed short-circuit setting range 1920–32,000 A
Instantaneous short-circuit setting range 4800–48,000 A
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 100 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Main terminal position Rear
Terminal orientation Horizontal
Main-circuit connection Bolt connection
Auxiliary contacts 4 change-over contacts
Trip contact Yes
Position indication Circuit breaker open / closed
Degree of protection IP30
Operating element Push button
Complete device including protection unit Yes
Motor drive integrated No
Motor drive optional Yes
Integrated undervoltage release No
DIN rail mounting No
Power loss 425 W
Net weight 56 kg
EAN / GTIN 8015644750152
Country of manufacture Italy
Standard / approval IEC

Frequently Asked Questions

What is the ABB 1SDA071165R1?

The ABB 1SDA071165R1 is a SACE Emax 2 E4.2H fixed three-pole air circuit breaker rated at 3200 A and equipped with an Ekip Touch LSI solid-state electronic trip unit.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E4.2H 3200?

The E4.2H 3200 provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s.

Does the ABB 1SDA071165R1 include earth-fault protection?

No. This model uses an LSI protection configuration, providing long-time, short-time and instantaneous protection without integrated earth-fault protection.

Where is the ABB E4.2H 3200 Ekip Touch LSI typically used?

It is designed for high-current low-voltage distribution applications including industrial switchboards, main distribution panels, transformer secondary systems, critical-power installations, infrastructure networks and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, substantial short-circuit performance and advanced electronic protection for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.