ABB 1SDA071160R1 Emax 2 E4.2S 3200 Ekip G Hi-Touch LSIG three-pole fixed air circuit breaker with a 3200 A rated uninterrupted current, 690 V AC operational voltage and 85 kA breaking capacity at 400–440 V AC for advanced generator and low-voltage power distribution protection.
£15,201.92
The ABB E4.2S 3200 Ekip G Hi-Touch LSIG 3p FHR, order code 1SDA071160R1, is a high-performance air circuit breaker (ACB) designed for advanced protection, switching and isolation in generator and low-voltage power distribution systems. As part of the ABB Emax 2 air circuit breaker series, it combines a 3200 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic trip unit for demanding industrial, power-generation, infrastructure and critical-power applications.
The E4.2S performance level provides high short-circuit capability, with a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC. Its Ekip G Hi-Touch LSIG solid-state electronic release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with generator-oriented functionality for comprehensive protection and selective coordination.
With a rated operational voltage of 690 V AC, three-pole construction and fixed installation with rear horizontal terminals, the 1SDA071160R1 is designed for integration into high-capacity low-voltage switchboards and generator distribution assemblies. The breaker provides a rated short-time withstand current of 66 kA for 1 s, supporting selective protection strategies in demanding electrical networks.
Air circuit breakers such as the ABB Emax 2 E4.2S provide switching, isolation and protection for high-current low-voltage distribution systems. The high breaking capacity of the E4.2S enables the breaker to interrupt severe short-circuit currents while helping protect generators, switchboards, busbars, cables and downstream electrical equipment.
The Ekip G Hi-Touch LSIG electronic trip unit combines advanced generator-oriented functionality with long-time, short-time, instantaneous and earth-fault protection. Its comprehensive protection capabilities support selective coordination and make the breaker particularly suitable for generator systems, industrial power networks and critical installations requiring sophisticated electrical protection.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Series | Emax 2 E4.2 |
| Performance level | S |
| Order code / SKU | 1SDA071160R1 |
| EAN | 8015644750107 |
| Product type | Air circuit breaker (ACB) |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Trip unit | Ekip G Hi-Touch LSIG electronic release |
| Release type | Electronic (EL) |
| Protection functions | Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth fault (G) |
| Overload protection adjustment range | 1280–3200 A |
| Short-time delayed short-circuit adjustment range | 1920–32000 A |
| Instantaneous short-circuit adjustment range | 4800–48000 A |
| Ultimate short-circuit breaking capacity (Icu) at 400 / 415 / 440 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 / 525 / 690 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 66 kA |
| Installation | Fixed |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Auxiliary contacts | 4 |
| Integrated earth-fault protection | Yes |
| Suitable for IT networks | Yes, up to 690 V |
| Power loss | 425 W |
| Electrical durability | 7000 cycles |
| Mechanical durability | 20000 cycles |
| Dimensions (W × H × D) | 384 × 371 × 270 mm |
| Weight | 56 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071160R1 is an Emax 2 air circuit breaker designed for switching, isolation and advanced protection in high-current generator and low-voltage power distribution systems.
The breaker has a rated uninterrupted current of 3200 A, making it suitable for high-current switchboards, generator systems and power distribution installations.
The E4.2S has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with functionality designed for generator protection applications.
The 1SDA071160R1 is a fixed three-pole air circuit breaker with rear flat horizontal main terminals for integration into generator switchboards and low-voltage power distribution assemblies.
ABB Emax 2 air circuit breakers are engineered for advanced protection and control of generator and low-voltage electrical distribution systems, combining high short-circuit performance with intelligent Ekip electronic protection technology.