1SDA071157R1 ABB E4.2S 3200 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

1SDA071157R1 ABB E4.2S 3200 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA071157R1 E4.2S 3200 Ekip G Touch LSIG 3p F HR is a fixed three-pole 3200 A SACE Emax 2 air circuit breaker with 85 kA breaking capacity at 415 V AC, generator-oriented Ekip G Touch LSIG electronic protection and integrated earth-fault protection.

SKU: 1SDA071157R1MPN: 1SDA071157R1
Price
List Price £19,411.70 ex VAT
Your Price (ex VAT) Save 25%
£14,558.78 25% OFF
You save £4,852.93 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £14,558.78
Trade pricing is personalised to your account

Manufacturer Lead Time

£14,558.78

Why Choose the ABB E4.2S 3200 Ekip G Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip G Touch LSIG 3p F HR, order code 1SDA071157R1, is a high-performance air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 3200 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit.

The Ekip G Touch LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, together with functionality intended for generator applications. Its electronic interface supports configurable protection and monitoring, helping engineers coordinate protection across generation and distribution systems while maintaining effective fault discrimination.

The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC, together with a short-time withstand current of 66 kA for 1 s. This version features a fixed three-pole construction with rear flat horizontal terminals and four auxiliary contacts for integration with control and signalling systems.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for generator and power distribution applications.
  • 3200 A rated uninterrupted current for high-current electrical installations.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA breaking capacity at 500–690 V AC.
  • Advanced Ekip G Touch LSIG electronic trip unit with generator-oriented protection functionality.
  • Integrated earth-fault protection alongside overload and short-circuit protection.
  • 100% service short-circuit breaking capacity relative to Icu.
  • Fixed three-pole construction with rear flat horizontal terminals.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated uninterrupted current.
  • Three-pole fixed air circuit breaker.
  • Ekip G Touch LSIG electronic protection release.
  • Long-time overload (L), short-time delayed (S), instantaneous short-circuit (I) and earth-fault (G) protection.
  • Generator-oriented electronic protection functionality.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 3 s.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • Rear flat horizontal main circuit connections.

Advanced Generator and Power Distribution Protection

Generator circuits can require specialised protection because fault behaviour and operating conditions differ from conventional utility-fed distribution systems. The ABB E4.2S 3200 with Ekip G Touch combines high-current switching capability with generator-oriented electronic protection, making it suitable for generator switchboards, standby power systems and industrial generation installations.

The Ekip G Touch LSIG release combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection with configurable electronic functionality for generator applications. Together with the E4.2S frame's 3200 A current capability and high short-circuit performance, this supports selective coordination, reliable fault isolation and protection of generators, conductors, switchgear and connected equipment.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency generation systems.
  • Industrial generation and power distribution installations.
  • Main low-voltage electrical distribution switchboards.
  • High-current main incomer applications.
  • Systems requiring integrated earth-fault protection.
  • Commercial and infrastructure power systems.
  • Data centres and critical power distribution systems.
  • OEM switchgear and electrical panel building.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame E4.2S
ABB order code / MPN 1SDA071157R1
Product type Air circuit breaker
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) 85 kA at 400–440 V AC; 66 kA at 500–690 V AC
Service short-circuit breaking capacity (Ics) 85 kA at 380–440 V AC; 66 kA at 500–690 V AC
Ics relative to Icu 100%
Short-time withstand current (Icw) 66 kA for 1 s; 66 kA for 3 s
Number of poles 3
Current type AC
Trip unit Ekip G Touch LSIG
Release type Electronic
Protection functions LSIG with generator-oriented protection functionality
Overload release adjustment range 1280–3200 A
Short-time delayed short-circuit adjustment range 1920–32000 A
Earth-fault protection Integrated
Short-circuit performance level S
Installation version Fixed
Main terminal orientation Rear flat horizontal
Connecting capacity 3000 mm²
Auxiliary contacts 4
Open/closed position indication Yes
Suitable for IT networks Yes, up to 690 V
Mechanical durability 20,000 cycles
Electrical durability 7,000 cycles at Ue ≤ 440 V; 7,000 cycles at Ue 500–690 V
Power loss 425 W
Dimensions (W × H × D) 384 × 371 × 270 mm
Net weight 56 kg
Standard IEC
Country of origin Italy
EAN / GTIN 8015644750077

Frequently Asked Questions

What is the ABB 1SDA071157R1 used for?

The ABB 1SDA071157R1 is an Emax 2 air circuit breaker designed for high-current low-voltage power distribution and generator protection applications, combining a 3200 A E4.2S breaker with the Ekip G Touch LSIG electronic trip unit.

What is the current rating of the ABB E4.2S 3200?

The circuit breaker has a rated uninterrupted current of 3200 A, making it suitable for substantial generator circuits and high-current low-voltage power distribution systems.

What breaking capacity does the ABB 1SDA071157R1 provide?

The E4.2S 3200 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

What protection functions are provided by the Ekip G Touch LSIG trip unit?

The Ekip G Touch LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with functionality intended for generator applications.

Is the ABB 1SDA071157R1 a fixed or withdrawable circuit breaker?

The 1SDA071157R1 is a fixed three-pole air circuit breaker equipped with rear flat horizontal terminals for integration into low-voltage switchboards and generator protection assemblies.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are designed for reliable protection, control and monitoring of low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection for demanding industrial, commercial and generator applications.