1SDA071153R1 ABB E4.2S 3200 Ekip Dip LSIG 3p FHR Air Circuit Breaker

1SDA071153R1 ABB E4.2S 3200 Ekip Dip LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071153R1 SACE Emax 2 E4.2S fixed three-pole air circuit breaker with Ekip Dip LSIG electronic protection, 3200 A rated current, 690 V AC rating and 85 kA breaking capacity at 400 V AC.

SKU: 1SDA071153R1MPN: 1SDA071153R1
Price
List Price £16,098.43 ex VAT
Your Price (ex VAT) Save 25%
£12,073.82 25% OFF
You save £4,024.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £12,073.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£12,073.82

Why Choose the ABB E4.2S 3200 Ekip Dip LSIG 3p FHR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip Dip LSIG 3p FHR, order code 1SDA071153R1, is a high-current SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB Emax 2 E4.2 series, this fixed three-pole breaker combines a 3200 A rated uninterrupted current with the Ekip Dip LSIG solid-state electronic trip unit.

The Ekip Dip LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and integrated earth-fault protection. Its adjustable electronic protection functions make the breaker suitable for high-current systems where coordinated fault protection and earth-fault detection are required.

The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400 V AC, while the breaker is rated for operation at 690 V AC. Supplied as a fixed three-pole unit with rear horizontal terminals, four change-over auxiliary contacts and open/closed position indication, the 1SDA071153R1 is engineered for dependable integration into major industrial and infrastructure switchboards.

Key Advantages

  • High-current ABB SACE Emax 2 E4.2S air circuit breaker.
  • 3200 A rated uninterrupted current for major low-voltage distribution circuits.
  • 85 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Ekip Dip LSIG electronic trip unit provides comprehensive four-function protection.
  • Integrated earth-fault protection provides additional protection for distribution systems.
  • Adjustable long-time, short-time and instantaneous protection supports coordinated system design.
  • Fixed three-pole construction for permanent switchboard installations.
  • Rear horizontal terminals support practical connection to high-current busbar systems.
  • Four change-over auxiliary contacts provide circuit-breaker status signalling capability.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Dip LSIG solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Overload release adjustable from 1280–3200 A.
  • Short-time delayed short-circuit release adjustable from 1920–32,000 A.
  • Instantaneous short-circuit release adjustable from 4800–48,000 A.
  • Rated voltage of 690 V AC.
  • 85 kA Icu at 400 V AC.
  • Rear horizontal main terminals.
  • Four change-over auxiliary contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor drive capability.

Comprehensive LSIG Protection for High-Current Distribution

The ABB SACE Emax 2 E4.2S is designed for major low-voltage distribution points where a high continuous current rating and substantial short-circuit interruption capability are essential. With a 3200 A rated uninterrupted current and 85 kA breaking capacity at 400 V AC, the breaker provides robust protection for switchboards, busbars, feeders, transformers and connected electrical equipment.

The Ekip Dip LSIG trip unit combines overload, short-time, instantaneous and earth-fault protection in a single electronic release. Adjustable short-time protection can support selective coordination with downstream devices, while the integrated earth-fault function extends protection to ground-fault conditions, making the 1SDA071153R1 suitable for critical high-current distribution networks.

Typical Applications

  • High-current low-voltage main switchboards.
  • Industrial power distribution systems.
  • Main incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Heavy-industry low-voltage distribution.
  • Systems requiring integrated earth-fault protection.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E4.2
ABB order code 1SDA071153R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level S
Rated uninterrupted current (Iu) 3200 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Dip LSIG
Release type Solid-state electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Integrated earth-fault protection Yes
Overload release setting range 1280–3200 A
Short-time delayed short-circuit setting range 1920–32,000 A
Instantaneous short-circuit setting range 4800–48,000 A
Rated voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 85 kA
Main terminal position Rear
Terminal orientation Horizontal
Terminal configuration Rear flat horizontal
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Motor drive Optional
DIN rail mounting No
Width 384 mm
Depth 270 mm
EAN 8015644750039
Country of origin Italy
Standard / approval IEC

Frequently Asked Questions

What is the ABB 1SDA071153R1?

The ABB 1SDA071153R1 is a SACE Emax 2 E4.2S fixed three-pole air circuit breaker rated at 3200 A and equipped with an Ekip Dip LSIG solid-state electronic trip unit.

What protection functions does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG release provides long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E4.2S 3200?

The ABB E4.2S 3200 has an ultimate short-circuit breaking capacity of 85 kA at 400 V AC, 50 Hz.

Does the ABB 1SDA071153R1 include earth-fault protection?

Yes. The Ekip Dip LSIG release includes integrated earth-fault protection in addition to long-time, short-time and instantaneous protection.

Where is the ABB E4.2S 3200 Ekip Dip LSIG typically used?

It is designed for high-current low-voltage distribution applications including industrial switchboards, main distribution panels, transformer secondary systems, critical-power installations, infrastructure networks and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, robust short-circuit performance and comprehensive electronic protection for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.