1SDA071152R1 ABB E4.2S 3200 Ekip Dip LSI 3p FHR Air Circuit Breaker

1SDA071152R1 ABB E4.2S 3200 Ekip Dip LSI 3p FHR Air Circuit Breaker

ABB 1SDA071152R1 Emax 2 E4.2S 3200 fixed three-pole air circuit breaker with Ekip Dip LSI electronic protection, 3200 A rated current and 85 kA breaking capacity at 400–440 V AC.

SKU: 1SDA071152R1MPN: 1SDA071152R1
Price
List Price £15,455.31 ex VAT
Your Price (ex VAT) Save 25%
£11,591.48 25% OFF
You save £3,863.83 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,591.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,591.48

Why Choose the ABB E4.2S 3200 Ekip Dip LSI 3p FHR Air Circuit Breaker?

The ABB E4.2S 3200 Ekip Dip LSI 3p FHR, order code 1SDA071152R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB Emax 2 E4.2 series, this fixed three-pole breaker combines a 3200 A rated current with the dependable Ekip Dip LSI electronic trip unit.

The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. This three-stage protection arrangement supports effective coordination between upstream and downstream devices, while DIP-switch configuration provides a straightforward method of setting the electronic protection functions.

The E4.2S performance level provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. With a rated operational voltage of 690 V AC, 66 kA short-time withstand current and rear flat horizontal terminals, the 1SDA071152R1 is well suited to high-current industrial, infrastructure and critical-power switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E4.2S air circuit breaker.
  • 3200 A rated current for demanding high-current distribution systems.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA ultimate short-circuit breaking capacity at 500–690 V AC.
  • 66 kA rated short-time withstand current for 1 s.
  • Ekip Dip LSI electronic trip unit provides overload and two-stage short-circuit protection.
  • Short-time protection supports selective coordination with downstream protective devices.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear flat horizontal terminals support efficient connection to high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E4.2S series.
  • 3200 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Dip LSI solid-state electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Protection settings configured using DIP switches.
  • Rated operational voltage of 690 V AC.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA Icw for 1 s and 3 s.
  • Rear flat horizontal main terminals.
  • Four auxiliary contacts fitted.
  • Circuit-breaker open/closed position indication.

Reliable LSI Protection for High-Current Power Distribution

The ABB SACE Emax 2 E4.2S is engineered for major low-voltage distribution points where high continuous currents and substantial prospective short-circuit levels demand robust switching and protection. Its combination of a 3200 A current rating, 85 kA breaking capacity at 400–440 V AC and 66 kA short-time withstand capability provides dependable protection for busbars, cables, transformers and connected equipment.

The Ekip Dip LSI electronic trip unit provides long-time overload, short-time and instantaneous short-circuit protection. The short-time function supports selective coordination between protective devices, helping isolate the circuit affected by a fault while maintaining continuity elsewhere in the distribution system where the installation design permits.

Typical Applications

  • High-current low-voltage main switchboards.
  • Industrial power distribution systems.
  • Main incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Utility and heavy-industry low-voltage distribution.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E4.2
ABB order code 1SDA071152R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level S
Rated current (In) 3200 A
Rated uninterrupted current (Iu) 3200 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Dip LSI
Release type Electronic / solid-state
Protection functions Long-time, short-time and instantaneous (LSI)
Earth-fault protection No
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) at 380–440 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 500–690 V AC 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Main terminal position Rear
Terminal configuration Rear flat horizontal
Terminal type Bolt
Connecting capacity 3000 mm²
Recommended main-circuit screw M12
Tightening torque 70 N·m
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Suitable for IT networks Yes, up to 690 V
Power loss 425 W
Electrical durability 7000 cycles at Ue ≤ 440 V AC; 7000 cycles at 500–690 V AC
Mechanical durability 20,000 cycles
Dimensions (W × H × D) 384 × 371 × 270 mm
Net weight 56 kg
EAN 8015644750022
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA071152R1?

The ABB 1SDA071152R1 is an Emax 2 E4.2S fixed three-pole air circuit breaker rated at 3200 A and equipped with an Ekip Dip LSI electronic trip unit.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E4.2S 3200?

The E4.2S 3200 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

Does the ABB 1SDA071152R1 include earth-fault protection?

No. This model uses an LSI protection configuration, providing long-time, short-time and instantaneous protection without integrated earth-fault protection.

Where is the ABB E4.2S 3200 Ekip Dip LSI typically used?

It is designed for high-current low-voltage distribution applications including industrial switchboards, main distribution panels, transformer secondary systems, critical-power installations, infrastructure networks and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, substantial short-circuit performance and dependable electronic protection for reliable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.