Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA071151R1 is a SACE Emax 2 E4.2S 3200 A fixed three-pole air circuit breaker with rear horizontal terminals, an Ekip Dip LI electronic trip unit and 85 kA ultimate breaking capacity at 400/415 V AC.
£11,313.75
The ABB E4.2S 3200 Ekip Dip LI 3p FHR, order code 1SDA071151R1, is a high-current SACE Emax 2 air circuit breaker (ACB) designed for reliable protection, switching and isolation in demanding low-voltage power distribution systems. Rated at 3200 A, this three-pole fixed circuit breaker combines the E4.2S frame with ABB's Ekip Dip LI solid-state electronic trip unit.
The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection. Its electronic protection architecture provides adjustable overload and instantaneous fault settings, making this configuration a practical solution for main incomers, high-current feeders and other circuits requiring dependable LI protection.
This configuration is a fixed three-pole breaker equipped with rear horizontal (HR) terminals. It provides an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC, 66 kA at 690 V AC and a rated short-time withstand current of 66 kA, making the 1SDA071151R1 suitable for demanding industrial, commercial and infrastructure distribution systems.
Air circuit breakers such as the ABB SACE Emax 2 protect high-current low-voltage distribution systems against damaging overloads and short circuits while providing controlled switching and isolation of major electrical circuits. The E4.2S frame combines a substantial 3200 A current rating with high short-circuit interruption and withstand capability for demanding industrial and infrastructure power systems.
The Ekip Dip LI trip unit provides adjustable electronic long-time overload and instantaneous short-circuit protection. Combined with the E4.2S frame's 85 kA breaking capacity at 400/415 V AC and 66 kA short-time withstand capability, this configuration provides dependable protection for main distribution systems, transformer-fed switchboards and high-current feeder circuits.
| Series | SACE Emax 2 |
|---|---|
| Frame | E4.2S |
| ABB order code | 1SDA071151R1 |
| EAN / GTIN | 8015644750015 |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 3200 A |
| Rated current (In) | 3200 A |
| Number of poles | 3 |
| Trip unit | Ekip Dip LI |
| Release type | Solid-state electronic |
| Protection functions | L and I |
| Overload release setting range | 1280–3200 A |
| Instantaneous short-circuit release setting range | 4800–48000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 400/415 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 66 kA |
| Rated short-time withstand current (Icw, 1 s) | 66 kA |
| Rated short-time withstand current (Icw, 3 s) | 66 kA |
| Rated service breaking capacity | 100% of Icu |
| Current type | AC |
| Short-circuit performance level | S |
| Installation | Fixed |
| Terminal configuration | Rear horizontal (HR) |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open / closed |
| Mechanical durability | 20000 cycles |
| Electrical durability at ≤440 V | 7000 cycles |
| Power loss | 425 W |
| Standard | IEC |
| Country of origin | Italy |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA071151R1 is a SACE Emax 2 E4.2S fixed three-pole air circuit breaker rated at 3200 A and equipped with an Ekip Dip LI solid-state electronic trip unit.
The Ekip Dip LI release provides long-time overload (L) and instantaneous short-circuit (I) protection.
The circuit breaker has a rated uninterrupted current of 3200 A.
The E4.2S provides an ultimate short-circuit breaking capacity of 85 kA at 400/415 V AC and 66 kA at 690 V AC.
The circuit breaker has a rated short-time withstand current of 66 kA for both 1 s and 3 s.
No. The supplied Ekip Dip LI configuration provides long-time overload and instantaneous short-circuit protection; integrated earth-fault protection is not included in this LI configuration.
The 1SDA071151R1 is a fixed-version circuit breaker intended for permanent installation within a low-voltage switchboard.
This configuration is a fixed circuit breaker with rear horizontal terminals, providing rear-facing main connections suitable for integration with switchboard busbars and conductors.
ABB SACE Emax 2 air circuit breakers combine high-current switching and protection with proven electronic trip technology and robust short-circuit performance for demanding industrial, commercial, infrastructure and power distribution installations worldwide.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.