1SDA071122R1 ABB E4.2V 2500 Ekip Dip LSI 3p F HR Air Circuit Breaker

1SDA071122R1 ABB E4.2V 2500 Ekip Dip LSI 3p F HR Air Circuit Breaker

ABB 1SDA071122R1 Emax 2 E4.2V 2500 air circuit breaker, a 2500 A three-pole fixed ACB with Ekip Dip LSI electronic protection, 150 kA short-circuit breaking capacity at 440 V AC and 100 kA short-time withstand current for 1 s.

SKU: 1SDA071122R1MPN: 1SDA071122R1
Price
List Price £15,845.09 ex VAT
Your Price (ex VAT) Save 25%
£11,883.82 25% OFF
You save £3,961.27 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,883.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,883.82

Why Choose the ABB E4.2V 2500 Ekip Dip LSI 3p F HR Air Circuit Breaker?

The ABB E4.2V 2500 Ekip Dip LSI 3p F HR, order code 1SDA071122R1, is a high-performance Emax 2 air circuit breaker (ACB) designed for reliable protection and switching in demanding low-voltage electrical distribution systems. As part of the ABB SACE Emax 2 series, it combines a 2500 A rated uninterrupted current with very high short-circuit performance for industrial, infrastructure and critical power installations.

This fixed three-pole circuit breaker incorporates the Ekip Dip LSI electronic trip unit, providing long-time overload, selective short-time and instantaneous short-circuit protection. DIP-switch adjustment provides straightforward configuration of the principal protection thresholds, making the breaker suitable for installations requiring dependable electronic protection with simple local setting.

With a rated uninterrupted current of 2500 A, the E4.2V is engineered for electrical systems with exceptionally high prospective fault levels. The V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s. Its fixed three-pole construction and rear horizontal terminals enable integration into high-current low-voltage switchboards.

Key Advantages

  • High-performance 2500 A Emax 2 air circuit breaker for demanding power distribution systems.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • High 100 kA short-time withstand current for 1 s for demanding selective distribution systems.
  • Ekip Dip LSI electronic trip unit for overload and short-circuit protection.
  • Long-time, selective short-time and instantaneous protection functions.
  • DIP-switch configuration provides straightforward adjustment of protection settings.
  • Fixed three-pole design with rear horizontal connections for switchboard integration.
  • Robust Emax 2 construction designed for high-current industrial and infrastructure applications.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 2500 A rated uninterrupted current.
  • Three-pole fixed configuration.
  • V high-breaking-capacity performance level.
  • 150 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Ekip Dip LSI electronic release.
  • Long-time overload protection.
  • Selective short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Simple DIP-switch protection adjustment.
  • Rear horizontal terminal connections.
  • Four auxiliary change-over contacts.
  • Optional motor operating mechanism capability.

High-Performance Protection for Critical Power Distribution

Air circuit breakers such as the ABB Emax 2 E4.2V protect high-current low-voltage distribution systems against overload and short-circuit conditions while providing controlled switching and isolation. The E4.2V performance level is designed for networks with particularly high prospective fault currents, providing substantial breaking and short-time withstand capabilities for robust system protection and coordination.

The Ekip Dip LSI electronic trip unit combines long-time overload protection with selective short-time and instantaneous short-circuit protection. Its adjustable protection functions support effective coordination between upstream and downstream protective devices, while the DIP-switch interface provides straightforward local configuration for industrial switchboard applications.

Typical Applications

  • Main low-voltage switchboards and power distribution boards.
  • High-fault-level industrial electrical systems.
  • Manufacturing and process facilities.
  • Data centres and critical power infrastructure.
  • Large commercial and infrastructure installations.
  • Transformer secondary and main incomer protection.
  • High-current feeder protection.
  • Low-voltage switchgear requiring high short-circuit performance.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071122R1
EAN 8015644749729
Product type Air circuit breaker (ACB)
Frame E4.2
Short-circuit performance level V
Rated uninterrupted current (Iu) 2500 A
Rated ultimate short-circuit breaking capacity (Icu) 150 kA at 440 V AC
Rated short-time withstand current (Icw) 100 kA for 1 s
Number of poles 3
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions Long-time overload, selective short-time and instantaneous short circuit
Integrated earth-fault protection No
Mounting type Fixed
Terminal connection Rear horizontal
Auxiliary change-over contacts 4
Optional motor operator Yes

Frequently Asked Questions

What is the ABB 1SDA071122R1 used for?

The ABB 1SDA071122R1 is an Emax 2 air circuit breaker designed for switching and protection of high-current low-voltage electrical distribution systems, particularly installations with high prospective short-circuit currents.

What is the current rating of the ABB E4.2V 2500?

The circuit breaker has a rated uninterrupted current of 2500 A, making it suitable for high-current industrial, infrastructure and critical power distribution systems.

What is the breaking capacity of the ABB 1SDA071122R1?

The E4.2V 2500 provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC, together with a rated short-time withstand current of 100 kA for 1 s.

What protection does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI electronic trip unit provides long-time overload, selective short-time and instantaneous short-circuit protection, with protection settings configured using DIP switches.

Is the ABB 1SDA071122R1 fixed or withdrawable?

The 1SDA071122R1 is a fixed three-pole air circuit breaker with rear horizontal connections for integration into low-voltage switchboards.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, dependable electronic protection and robust construction for demanding industrial, infrastructure and critical low-voltage power distribution applications.