1SDA071110R1 ABB E4.2V 2000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker

1SDA071110R1 ABB E4.2V 2000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA071110R1 E4.2V 2000 Ekip G Hi-Touch LSIG is a fixed three-pole 2000 A SACE Emax 2 air circuit breaker with rear horizontal terminals, 150 kA breaking capacity at 400–440 V AC and advanced LSIG generator protection.

SKU: 1SDA071110R1MPN: 1SDA071110R1
Price
List Price £18,378.72 ex VAT
Your Price (ex VAT) Save 25%
£13,784.04 25% OFF
You save £4,594.68 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,784.04
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,784.04

Why Choose the ABB E4.2V 2000 Ekip G Hi-Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E4.2V 2000 Ekip G Hi-Touch LSIG 3p F HR, order code 1SDA071110R1, is a high-performance 2000 A three-pole air circuit breaker (ACB) designed for advanced generator protection and demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines the high-breaking-capacity E4.2V platform with an Ekip G Hi-Touch LSIG electronic trip unit, fixed installation and rear horizontal terminals.

This breaker provides a rated uninterrupted current of 2000 A and an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC. Its rated short-time withstand current is 100 kA for 1 s, providing exceptional performance in electrical networks with very high prospective fault currents.

The Ekip G Hi-Touch LSIG release provides long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented protection, measurement and monitoring capabilities. The 1SDA071110R1 is supplied as a fixed three-pole breaker with rear horizontal terminals and four auxiliary contacts for open/closed breaker status signalling.

Key Advantages

  • Premium ABB SACE Emax 2 air circuit breaker for generator and power-distribution protection.
  • 2000 A rated uninterrupted current for high-current electrical systems.
  • Ekip G Hi-Touch LSIG electronic trip unit with advanced generator protection functionality.
  • Long-time, short-time, instantaneous and earth-fault protection.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 100 kA short-time withstand current for 1 s.
  • Fixed three-pole configuration with rear horizontal terminals.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 2000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed mounting design.
  • Rear horizontal main terminals.
  • Ekip G Hi-Touch LSIG solid-state electronic release.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Advanced generator protection and electrical monitoring capabilities.
  • 150 kA Icu at 400–440 V AC.
  • 100 kA Icw for 1 s.
  • Rated operational voltage up to 690 V AC.
  • Four auxiliary contacts with open/closed breaker position indication.

Advanced Generator and High-Fault-Level Protection

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and protection for high-current low-voltage electrical systems. The E4.2V performance class delivers exceptionally high short-circuit interruption capability, making it suitable for networks where very high prospective fault currents demand robust and selective protection.

The Ekip G Hi-Touch LSIG release combines comprehensive LSIG circuit protection with advanced functionality for generator applications. Its protection, measurement and monitoring capabilities support sophisticated power management while helping engineers coordinate protection throughout modern generation and distribution networks.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage distribution switchboards.
  • Industrial power generation and distribution systems.
  • Large manufacturing and process plants.
  • Critical infrastructure and standby power installations.
  • Transformer and generator distribution networks.
  • High-fault-level switchgear and power distribution assemblies.

Technical Specifications

Series SACE Emax 2
Order code 1SDA071110R1
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 2000 A
Rated operational voltage up to 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated short-time withstand current (Icw, 1 s) 100 kA
Number of poles 3
Current type AC
Mounting Fixed
Main terminal arrangement Rear horizontal
Trip unit Ekip G Hi-Touch LSIG
Protection functions Long-time, short-time, instantaneous and earth fault
Overload release adjustment range 800–2000 A
Short-time short-circuit adjustment range 1200–20000 A
Integrated earth-fault protection Yes
Auxiliary contacts 4
Breaker position indication Open / closed
EAN 8015644749606

Frequently Asked Questions

What is the ABB 1SDA071110R1 used for?

The ABB 1SDA071110R1 is a 2000 A air circuit breaker designed for advanced generator protection and high-current low-voltage power distribution systems with demanding fault levels.

What protection unit is fitted to this breaker?

The breaker is fitted with an ABB Ekip G Hi-Touch LSIG electronic trip unit, providing long-time, short-time, instantaneous and earth-fault protection together with advanced generator-oriented functionality.

What is the rated current of the ABB E4.2V 1SDA071110R1?

The breaker has a rated uninterrupted current of 2000 A.

Is the ABB 1SDA071110R1 fixed or withdrawable?

This model is a fixed three-pole air circuit breaker equipped with rear horizontal main terminals.

What is the breaking capacity of the E4.2V 2000?

The E4.2V 2000 has an ultimate short-circuit breaking capacity of 150 kA at 400–440 V AC and a short-time withstand current of 100 kA for 1 s, making it suitable for networks with very high prospective fault currents.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-specific functionality and exceptional short-circuit performance for dependable protection and control of modern generation and low-voltage power distribution systems.