ABB 1SDA071104R1 E4.2V 2000 Ekip Touch LI 3p F HR is a fixed three-pole 2000 A SACE Emax 2 air circuit breaker with 150 kA short-circuit breaking capacity and Ekip Touch LI electronic overload and instantaneous short-circuit protection.
£8,916.53
The ABB E4.2V 2000 Ekip Touch LI 3p F HR, order code 1SDA071104R1, is a high-performance air circuit breaker (ACB) designed for protection, control and isolation in demanding low-voltage electrical distribution systems. Part of the ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 2000 A rated current with the Ekip Touch LI electronic trip unit.
The Ekip Touch LI release provides long-time overload and instantaneous short-circuit protection through an advanced electronic interface. This configuration is particularly suited to applications requiring straightforward LI protection together with the measurement, configuration and operating capabilities of ABB's Ekip Touch platform.
The E4.2V performance level provides an exceptional 150 kA short-circuit breaking capacity at common low-voltage operating levels, making the breaker suitable for systems with very high prospective fault currents. This version features a fixed three-pole construction with rear horizontal terminals and is supplied with four auxiliary contacts plus circuit-breaker open/closed position indication.
Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical distribution systems against overloads and short circuits while providing dependable switching and isolation. The E4.2V frame combines a 2000 A current rating with exceptionally high short-circuit interruption capability, making it particularly suitable for installations where substantial prospective fault currents are present.
The Ekip Touch LI electronic trip unit combines long-time overload and instantaneous short-circuit protection with ABB's touchscreen-based electronic trip platform. This allows the breaker to provide dependable protection for conductors, switchgear and connected equipment while supporting straightforward configuration and integration into modern low-voltage distribution systems.
| Series | SACE Emax 2 |
|---|---|
| ABB product group | Emax2 Air Circuit Breaker |
| Frame | E4.2V |
| ABB order code / MPN | 1SDA071104R1 |
| Product type | Air circuit breaker |
| Rated current | 2000 A |
| Rated voltage | 690 V |
| Breaking capacity | 150 kA |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip Touch LI |
| Release type | Solid-state electronic |
| Protection functions | LI |
| Long-time protection | Overload protection |
| Instantaneous protection | Short-circuit protection |
| Earth-fault protection | Not included in LI configuration |
| Short-circuit performance level | V |
| Installation version | Fixed |
| Main terminal position | Rear |
| Main terminal orientation | Rear horizontal |
| Auxiliary contacts | 4 |
| Open/closed position indication | Yes |
| Dimensions | 384 × 371 × 270 mm |
| Standard | IEC |
| Country of origin | Italy |
| EAN / GTIN | 8015644749545 |
The ABB 1SDA071104R1 is an Emax 2 air circuit breaker designed to protect, control and isolate high-current low-voltage electrical distribution circuits, particularly in installations requiring very high short-circuit breaking performance.
The circuit breaker has a rated current of 2000 A, making it suitable for substantial industrial, commercial and infrastructure power distribution circuits.
The E4.2V 2000 is a high-performance breaker configuration with a 150 kA short-circuit breaking capacity, making it suitable for electrical systems with very high prospective fault currents.
The Ekip Touch LI trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. This LI configuration does not incorporate the short-time or earth-fault protection functions found in LSI and LSIG variants.
The 1SDA071104R1 is a fixed three-pole air circuit breaker equipped with rear horizontal terminals for integration into low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers are engineered for reliable protection and control of demanding low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection for industrial, commercial and infrastructure installations.