1SDA071103R1 ABB E4.2V 2000 Ekip Dip LSIG 3p FHR Air Circuit Breaker

1SDA071103R1 ABB E4.2V 2000 Ekip Dip LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071103R1 Emax 2 E4.2V 2000 fixed three-pole air circuit breaker with Ekip Dip LSIG electronic protection, 2000 A rated current, 150 kA breaking capacity at 440 V AC and integrated earth-fault protection.

SKU: 1SDA071103R1MPN: 1SDA071103R1
Price
List Price £13,136.06 ex VAT
Your Price (ex VAT) Save 25%
£9,852.05 25% OFF
You save £3,284.02 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,852.05
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,852.05

Why Choose the ABB E4.2V 2000 Ekip Dip LSIG 3p FHR Air Circuit Breaker?

The ABB E4.2V 2000 Ekip Dip LSIG 3p FHR, order code 1SDA071103R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB Emax 2 E4.2 series, this fixed three-pole breaker combines a 2000 A rated current with the Ekip Dip LSIG electronic trip unit.

The Ekip Dip LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. This comprehensive protection arrangement makes the breaker suitable for high-current systems where selective coordination, rapid fault interruption and integrated earth-fault protection are required.

The E4.2V performance level provides an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and 100 kA at 690 V AC, together with a rated short-time withstand current of 100 kA for 1 s. Its fixed three-pole construction and rear horizontal connections make the 1SDA071103R1 a robust choice for high-fault-level industrial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E4.2V air circuit breaker.
  • 2000 A rated current for high-current low-voltage distribution systems.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA ultimate short-circuit breaking capacity at 690 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Ekip Dip LSIG electronic trip unit provides comprehensive four-function protection.
  • Integrated earth-fault protection helps protect distribution systems against ground faults.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear horizontal terminals support efficient integration with high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 2000 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Dip LSIG electronic protection release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Protection settings configured using DIP switches.
  • Rated operational voltage of 690 V AC.
  • 150 kA Icu at 380–440 V AC.
  • 100 kA Icu at 500–690 V AC.
  • 100 kA Icw for 1 s.
  • Rear horizontal main connections.

High-Capacity LSIG Protection for Critical Power Distribution

The ABB SACE Emax 2 E4.2V is engineered for low-voltage installations where very high prospective short-circuit currents require exceptional interruption and withstand performance. Its combination of a 2000 A rated current, 150 kA breaking capacity at 440 V AC and 100 kA short-time withstand capability makes it particularly suitable for critical points within large industrial and infrastructure distribution networks.

The Ekip Dip LSIG electronic trip unit provides long-time, short-time, instantaneous and earth-fault protection. The combination of short-time and earth-fault functions supports selective system design and comprehensive fault protection, helping isolate affected circuits while protecting cables, busbars, transformers and connected equipment.

Typical Applications

  • High-fault-level low-voltage main switchboards.
  • Industrial power distribution systems.
  • High-current incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Utility and heavy-industry low-voltage distribution.
  • Installations requiring integrated earth-fault protection.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E4.2
ABB order code 1SDA071103R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level V
Rated current (In) 2000 A
Current type AC
Number of poles 3
Version Fixed
Trip unit Ekip Dip LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Earth-fault protection Yes
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 380–440 V AC 150 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 660–690 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 380–440 V AC 150 kA
Service short-circuit breaking capacity (Ics) at 500 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 660–690 V AC 100 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw), 1 s 100 kA
Main terminal position Rear
Terminal orientation Horizontal
Connecting capacity 1600 mm²
Power loss 425 W
Electrical durability 10,000 cycles at Ue ≤ 440 V AC; 10,000 cycles at 500–690 V AC
Mechanical durability 20,000 cycles
EAN 8015644749538
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071103R1?

The ABB 1SDA071103R1 is an Emax 2 E4.2V fixed three-pole air circuit breaker rated at 2000 A and equipped with an Ekip Dip LSIG electronic trip unit.

What protection functions does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What is the breaking capacity of the ABB E4.2V 2000?

The E4.2V 2000 provides an ultimate short-circuit breaking capacity of 150 kA at 380–440 V AC and 100 kA at 690 V AC, with a rated short-time withstand current of 100 kA for 1 s.

Does the ABB 1SDA071103R1 provide earth-fault protection?

Yes. Its Ekip Dip LSIG release includes integrated earth-fault protection in addition to long-time, short-time and instantaneous protection.

Where is the ABB E4.2V 2000 Ekip Dip LSIG typically used?

It is designed for demanding low-voltage distribution applications including industrial switchboards, high-fault-level main distribution panels, transformer secondary systems, critical-power installations, infrastructure networks and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine exceptional short-circuit performance, comprehensive electronic fault protection and robust switchboard integration for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.