1SDA071102R1 ABB E4.2V 2000 Ekip Dip LSI 3p FHR Air Circuit Breaker

1SDA071102R1 ABB E4.2V 2000 Ekip Dip LSI 3p FHR Air Circuit Breaker

ABB 1SDA071102R1 Emax 2 E4.2V 2000 fixed three-pole air circuit breaker with Ekip Dip LSI electronic protection, 2000 A rated current, 150 kA breaking capacity at 440 V AC and 100 kA short-time withstand current.

SKU: 1SDA071102R1MPN: 1SDA071102R1
Price
List Price £12,317.46 ex VAT
Your Price (ex VAT) Save 25%
£9,238.10 25% OFF
You save £3,079.37 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,238.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,238.10

Why Choose the ABB E4.2V 2000 Ekip Dip LSI 3p FHR Air Circuit Breaker?

The ABB E4.2V 2000 Ekip Dip LSI 3p FHR, order code 1SDA071102R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB Emax 2 E4.2 series, this fixed three-pole breaker combines a 2000 A rated current with the dependable Ekip Dip LSI electronic trip unit.

The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. Protection settings are configured using DIP switches, providing a straightforward electronic protection platform for installations where selective coordination and dependable fault isolation are required without integrated earth-fault protection.

The E4.2V performance level delivers an ultimate short-circuit breaking capacity of 150 kA at 440 V AC together with a rated short-time withstand current of 100 kA for 1 s. With a rated operational voltage up to 690 V AC, fixed three-pole construction and rear flat horizontal terminals, the 1SDA071102R1 is engineered for high-fault-level industrial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E4.2V air circuit breaker.
  • 2000 A rated current for high-current low-voltage distribution.
  • Exceptional 150 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 100 kA rated short-time withstand current for 1 s.
  • Ekip Dip LSI electronic trip unit provides three-stage circuit protection.
  • Long-time, short-time and instantaneous functions support effective protection coordination.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear flat horizontal terminals support efficient connection to high-current busbar systems.

Key Features

  • ABB SACE Emax 2 E4.2V series.
  • 2000 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Dip LSI electronic protection release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Protection settings configured using DIP switches.
  • Rated operational voltage up to 690 V AC.
  • 150 kA Icu at 440 V AC.
  • 100 kA Icw for 1 s.
  • Rear flat horizontal main terminals.
  • Designed for demanding high-fault-current distribution systems.

High-Capacity LSI Protection for Critical Power Distribution

The ABB SACE Emax 2 E4.2V is designed for low-voltage installations where exceptionally high prospective short-circuit currents demand substantial interruption and withstand performance. Its combination of a 2000 A continuous-current rating, 150 kA breaking capacity at 440 V AC and 100 kA short-time withstand capability makes it suitable for critical points within large industrial and infrastructure distribution networks.

The Ekip Dip LSI electronic trip unit provides long-time overload, short-time and instantaneous short-circuit protection. The short-time function enables improved coordination with downstream protective devices, helping isolate faults selectively while the instantaneous function provides rapid response to severe short-circuit conditions.

Typical Applications

  • High-fault-level low-voltage main switchboards.
  • Industrial power distribution systems.
  • High-current incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Large commercial and infrastructure installations.
  • Power distribution centres.
  • Transformer secondary distribution systems.
  • Data centre and critical-power switchboards.
  • Utility and heavy-industry low-voltage distribution.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E4.2
ABB order code 1SDA071102R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E4.2
Performance level V
Rated current 2000 A
Rated uninterrupted current (Iu) 2000 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Dip LSI
Release type Electronic
Protection functions Long-time, short-time and instantaneous (LSI)
Earth-fault protection No
Rated operational voltage Up to 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 150 kA
Rated short-time withstand current (Icw), 1 s 100 kA
Main terminal position Rear
Terminal configuration Rear flat horizontal
Connection arrangement F HR
Width 384 mm
Depth 270 mm
Product dimension 270 mm
Country of origin Italy
Standards / approvals IEC

Frequently Asked Questions

What is the ABB 1SDA071102R1?

The ABB 1SDA071102R1 is an Emax 2 E4.2V fixed three-pole air circuit breaker rated at 2000 A and equipped with an Ekip Dip LSI electronic trip unit.

What protection functions does the Ekip Dip LSI trip unit provide?

The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking capacity of the ABB E4.2V 2000?

The E4.2V 2000 has an ultimate short-circuit breaking capacity of 150 kA at 440 V AC and a rated short-time withstand current of 100 kA for 1 s.

Does the ABB 1SDA071102R1 provide earth-fault protection?

No. This model uses an LSI protection configuration, providing long-time, short-time and instantaneous protection without an integrated earth-fault protection function.

Where is the ABB E4.2V 2000 Ekip Dip LSI typically used?

It is designed for demanding low-voltage distribution applications including industrial switchboards, high-fault-level main distribution panels, transformer secondary systems, critical-power installations and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine exceptional short-circuit performance, configurable electronic protection and robust switchboard integration for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.