1SDA071080R1 ABB E2.2S 2500 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker

1SDA071080R1 ABB E2.2S 2500 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071080R1 Emax 2 E2.2S 2500 fixed three-pole air circuit breaker with Ekip G Hi-Touch LSIG electronic protection, 2500 A rated current and 85 kA breaking capacity at 400–440 V AC.

SKU: 1SDA071080R1MPN: 1SDA071080R1
Price
List Price £17,345.81 ex VAT
Your Price (ex VAT) Save 25%
£13,009.36 25% OFF
You save £4,336.45 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £13,009.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£13,009.36

Why Choose the ABB E2.2S 2500 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker?

The ABB E2.2S 2500 Ekip G Hi-Touch LSIG 3p FHR, order code 1SDA071080R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, monitoring and control of low-voltage power distribution and generator systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole breaker combines a 2500 A rated current with the sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced generator and power-system protection capabilities. The Hi-Touch platform also supports detailed electrical measurement and network analysis, making this breaker particularly suitable for critical installations where protection selectivity, system supervision and power quality are important.

The E2.2S 2500 has a rated operational voltage of 690 V AC and provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 690 V AC. Its fixed three-pole configuration with rear flat horizontal terminals is designed for efficient integration into high-current low-voltage switchboards.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for demanding power distribution and generator systems.
  • 2500 A rated current for high-current industrial and infrastructure applications.
  • 85 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 66 kA ultimate short-circuit breaking capacity at 690 V AC.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit.
  • LSIG protection covers overload, short-time, instantaneous and earth-fault conditions.
  • Generator-oriented protection capabilities suit sophisticated generation and power-distribution systems.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear flat horizontal terminals support efficient connection to switchboard busbars.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 2500 A rated current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip G Hi-Touch LSIG electronic release.
  • Long-time overload protection.
  • Short-time short-circuit protection.
  • Instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Advanced generator and power-system protection functionality.
  • Rated operational voltage of 690 V AC.
  • 85 kA Icu at 400–440 V AC.
  • 66 kA Icu at 690 V AC.
  • 66 kA short-time withstand current for 1 s.
  • Rear flat horizontal main terminals.
  • Suitable for IT networks up to 690 V.

Advanced Generator and Power-System Protection

Air circuit breakers such as the ABB SACE Emax 2 provide essential switching and fault protection at critical points within low-voltage electrical networks. The E2.2S 2500 combines a high 2500 A current rating with substantial short-circuit interruption and withstand performance, helping protect busbars, cables, generators and connected equipment against damaging electrical faults.

The Ekip G Hi-Touch LSIG electronic release combines comprehensive LSIG protection with advanced functionality intended for generator and sophisticated power-system applications. This makes the 1SDA071080R1 particularly suitable for installations requiring selective protection, earth-fault detection, system supervision and dependable operation of critical power assets.

Typical Applications

  • Generator protection and generator distribution systems.
  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • High-current incomer and feeder protection.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical installations.
  • Power distribution centres and substations.
  • Transformer secondary distribution systems.
  • Critical-power and standby generation systems.
  • Installations requiring integrated earth-fault protection.
  • OEM low-voltage switchboards and switchgear assemblies.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA071080R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Frame E2.2
Performance level S
Rated current (In) 2500 A
Rated uninterrupted current (Iu) 2500 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip G Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC 66 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Service short-circuit breaking capacity (Ics) at 400–440 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 500–690 V AC 66 kA
Ics as percentage of Icu 100%
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Main terminal position Rear
Terminal configuration Rear flat horizontal
Connecting capacity 1800 mm²
Recommended terminal screw M12
Suitable for IT networks Yes, up to 690 V
Power loss 267 W
Electrical durability 8000 cycles at Ue ≤ 440 V; 7000 cycles at 500–690 V
Mechanical durability 20,000 cycles
EAN 8015644749309
Country of origin Italy
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071080R1?

The ABB 1SDA071080R1 is an Emax 2 E2.2S fixed three-pole air circuit breaker rated at 2500 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced functions for generator and power-system applications.

What is the short-circuit breaking capacity of the ABB E2.2S 2500?

The E2.2S 2500 provides an ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 690 V AC.

Is the ABB 1SDA071080R1 fixed or withdrawable?

This model is a fixed three-pole air circuit breaker fitted with rear flat horizontal main terminals.

Where is the ABB E2.2S 2500 Ekip G Hi-Touch LSIG typically used?

It is designed for high-current low-voltage distribution and generator applications including industrial switchboards, generator systems, main distribution panels, critical-power installations, infrastructure systems and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-current switching, advanced generator protection and comprehensive electronic fault management for dependable low-voltage power distribution in critical industrial, commercial and infrastructure installations.