1SDA071075R1 ABB E2.2S 2500 Ekip Touch LSI 3p FHR Air Circuit Breaker

1SDA071075R1 ABB E2.2S 2500 Ekip Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA071075R1 Emax 2 E2.2S 2500 Ekip Touch LSI three-pole fixed air circuit breaker with a 2500 A rated uninterrupted current, 690 V AC rating and 85 kA breaking capacity at 400–440 V AC for low-voltage power distribution protection.

SKU: 1SDA071075R1MPN: 1SDA071075R1
Price
List Price £12,609.80 ex VAT
Your Price (ex VAT) Save 25%
£9,457.35 25% OFF
You save £3,152.45 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,457.35
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,457.35

Why Choose the ABB E2.2S 2500 Ekip Touch LSI 3p FHR Air Circuit Breaker?

The ABB E2.2S 2500 Ekip Touch LSI 3p FHR, order code 1SDA071075R1, is a high-performance air circuit breaker (ACB) designed for protection, switching and isolation in low-voltage power distribution systems. As part of the advanced ABB Emax 2 air circuit breaker series, it combines a 2500 A rated uninterrupted current with the intelligent Ekip Touch LSI electronic trip unit for dependable protection in industrial, commercial and infrastructure installations.

The E2.2S performance level provides high short-circuit capability, with a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC. Its Ekip Touch LSI solid-state electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, allowing protection settings to be coordinated with the requirements of the electrical distribution system.

With a rated voltage of 690 V AC, three-pole construction and fixed installation with rear horizontal terminals, the 1SDA071075R1 is designed for integration into low-voltage switchboards and power distribution assemblies. Its 66 kA rated short-time withstand current for 1 s supports selective protection strategies in demanding electrical networks.

Key Advantages

  • High-performance ABB Emax 2 air circuit breaker for low-voltage power distribution.
  • 2500 A rated uninterrupted current for high-current electrical installations.
  • 85 kA Icu at 400–440 V AC for demanding short-circuit protection requirements.
  • Advanced Ekip Touch LSI electronic trip unit with overload, short-time and instantaneous short-circuit protection.
  • 66 kA short-time withstand current for 1 s supports selective protection coordination.
  • Three-pole fixed configuration for switchboard and distribution-panel installations.
  • Rear horizontal terminals provide a practical connection arrangement for fixed switchboard installations.

Key Features

  • ABB Emax 2 E2.2S series.
  • 2500 A rated uninterrupted current (Iu).
  • 690 V AC rated voltage.
  • 85 kA ultimate short-circuit breaking capacity (Icu) at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 50 kA rated short-time withstand current (Icw) for 3 s.
  • Ekip Touch LSI solid-state electronic protection release.
  • Long-time overload, short-time and instantaneous short-circuit protection.
  • Three-pole fixed-mounted construction with rear horizontal terminals.
  • Four auxiliary contacts with circuit-breaker open/closed position indication.
  • Suitable for IT networks up to 690 V.

Selective Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB Emax 2 E2.2S provide switching, isolation and overcurrent protection for high-current low-voltage distribution systems. The high breaking capacity of the E2.2S enables the breaker to interrupt severe fault currents while helping protect switchboards, cables, busbars and downstream electrical equipment.

The Ekip Touch LSI electronic trip unit adds short-time protection to the long-time and instantaneous functions, providing greater flexibility for selective coordination than an LI-only configuration. This allows upstream and downstream protection devices to be coordinated so that faults can be isolated while helping maintain continuity of supply to unaffected parts of the electrical installation.

Typical Applications

  • Main incomer protection in low-voltage switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Transformer secondary protection.
  • Manufacturing facilities and process plants.
  • Infrastructure and utility installations.
  • High-current feeder protection.
  • Low-voltage switchgear and distribution assemblies.

Technical Specifications

Product group Emax 2 Air Circuit Breaker
Series Emax 2 E2.2
Performance level S
Order code / SKU 1SDA071075R1
EAN 8015644749255
Product type Air circuit breaker (ACB)
Rated uninterrupted current (Iu) 2500 A
Rated voltage 690 V AC
Number of poles 3
Trip unit Ekip Touch LSI electronic release
Release type Electronic (EL)
Protection functions Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I)
Ultimate short-circuit breaking capacity (Icu) at 400 / 415 / 440 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 500 / 525 / 690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Installation Fixed
Main terminal position Rear
Terminal configuration Rear flat horizontal
Terminal type Bolt
Auxiliary contacts 4
Suitable for IT networks Yes, up to 690 V
Electrical durability 8,000 cycles at Ue ≤ 440 V; 7,000 cycles at 500–690 V
Mechanical durability 20,000 cycles
Dimensions (H × W × D) 371 × 276 × 270 mm
Product net weight 60 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071075R1 used for?

The ABB 1SDA071075R1 is an Emax 2 air circuit breaker designed for switching, isolation and overcurrent protection in high-current low-voltage power distribution systems.

What is the current rating of the ABB E2.2S 2500?

The breaker has a rated uninterrupted current of 2500 A, making it suitable for high-current switchboards, feeders and electrical distribution installations.

What is the breaking capacity of the ABB 1SDA071075R1?

The E2.2S has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.

Is the ABB 1SDA071075R1 fixed or withdrawable?

The 1SDA071075R1 is a fixed three-pole air circuit breaker with rear horizontal main terminals for integration into low-voltage switchboards and distribution assemblies.

Trusted Power Protection from ABB

ABB Emax 2 air circuit breakers are engineered for reliable protection and control of low-voltage electrical distribution systems, combining high short-circuit performance with intelligent Ekip electronic protection technology.