ABB 1SDA071075R1 Emax 2 E2.2S 2500 Ekip Touch LSI three-pole fixed air circuit breaker with a 2500 A rated uninterrupted current, 690 V AC rating and 85 kA breaking capacity at 400–440 V AC for low-voltage power distribution protection.
£9,457.35
The ABB E2.2S 2500 Ekip Touch LSI 3p FHR, order code 1SDA071075R1, is a high-performance air circuit breaker (ACB) designed for protection, switching and isolation in low-voltage power distribution systems. As part of the advanced ABB Emax 2 air circuit breaker series, it combines a 2500 A rated uninterrupted current with the intelligent Ekip Touch LSI electronic trip unit for dependable protection in industrial, commercial and infrastructure installations.
The E2.2S performance level provides high short-circuit capability, with a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC. Its Ekip Touch LSI solid-state electronic release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection, allowing protection settings to be coordinated with the requirements of the electrical distribution system.
With a rated voltage of 690 V AC, three-pole construction and fixed installation with rear horizontal terminals, the 1SDA071075R1 is designed for integration into low-voltage switchboards and power distribution assemblies. Its 66 kA rated short-time withstand current for 1 s supports selective protection strategies in demanding electrical networks.
Air circuit breakers such as the ABB Emax 2 E2.2S provide switching, isolation and overcurrent protection for high-current low-voltage distribution systems. The high breaking capacity of the E2.2S enables the breaker to interrupt severe fault currents while helping protect switchboards, cables, busbars and downstream electrical equipment.
The Ekip Touch LSI electronic trip unit adds short-time protection to the long-time and instantaneous functions, providing greater flexibility for selective coordination than an LI-only configuration. This allows upstream and downstream protection devices to be coordinated so that faults can be isolated while helping maintain continuity of supply to unaffected parts of the electrical installation.
| Product group | Emax 2 Air Circuit Breaker |
|---|---|
| Series | Emax 2 E2.2 |
| Performance level | S |
| Order code / SKU | 1SDA071075R1 |
| EAN | 8015644749255 |
| Product type | Air circuit breaker (ACB) |
| Rated uninterrupted current (Iu) | 2500 A |
| Rated voltage | 690 V AC |
| Number of poles | 3 |
| Trip unit | Ekip Touch LSI electronic release |
| Release type | Electronic (EL) |
| Protection functions | Long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) |
| Ultimate short-circuit breaking capacity (Icu) at 400 / 415 / 440 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 / 525 / 690 V AC | 66 kA |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Installation | Fixed |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Terminal type | Bolt |
| Auxiliary contacts | 4 |
| Suitable for IT networks | Yes, up to 690 V |
| Electrical durability | 8,000 cycles at Ue ≤ 440 V; 7,000 cycles at 500–690 V |
| Mechanical durability | 20,000 cycles |
| Dimensions (H × W × D) | 371 × 276 × 270 mm |
| Product net weight | 60 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA071075R1 is an Emax 2 air circuit breaker designed for switching, isolation and overcurrent protection in high-current low-voltage power distribution systems.
The breaker has a rated uninterrupted current of 2500 A, making it suitable for high-current switchboards, feeders and electrical distribution installations.
The E2.2S has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC.
The Ekip Touch LSI electronic trip unit provides long-time overload, short-time short-circuit and instantaneous short-circuit protection.
The 1SDA071075R1 is a fixed three-pole air circuit breaker with rear horizontal main terminals for integration into low-voltage switchboards and distribution assemblies.
ABB Emax 2 air circuit breakers are engineered for reliable protection and control of low-voltage electrical distribution systems, combining high short-circuit performance with intelligent Ekip electronic protection technology.