1SDA071060R1 ABB E2.2H 2000 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker

1SDA071060R1 ABB E2.2H 2000 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071060R1 is a SACE Emax 2 E2.2H 2000 A fixed three-pole air circuit breaker with rear horizontal terminals, Ekip G Hi-Touch LSIG electronic protection and 100 kA ultimate breaking capacity at 400/415 V AC.

SKU: 1SDA071060R1MPN: 1SDA071060R1
Price
List Price £15,338.35 ex VAT
Your Price (ex VAT) Save 25%
£11,503.76 25% OFF
You save £3,834.59 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £11,503.76
Trade pricing is personalised to your account

Manufacturer Lead Time

£11,503.76

Why Choose the ABB E2.2H 2000 Ekip G Hi-Touch LSIG 3p FHR Air Circuit Breaker?

The ABB E2.2H 2000 Ekip G Hi-Touch LSIG 3p FHR, order code 1SDA071060R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection, control and monitoring of demanding low-voltage power distribution systems. Rated at 2000 A, this three-pole fixed circuit breaker combines the high-breaking-capacity E2.2H frame with ABB's sophisticated Ekip G Hi-Touch LSIG electronic trip unit.

The Ekip G Hi-Touch LSIG release provides comprehensive long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced generator-oriented protection and monitoring capabilities. This makes the breaker particularly suitable for installations where selective protection, detailed electrical supervision and dependable management of generators or other critical power sources are required.

This configuration is a fixed three-pole breaker with rear horizontal (HR) terminals. The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and a rated service short-circuit breaking capacity of 85 kA at 400/415 V AC, making the 1SDA071060R1 suitable for high-fault-level industrial switchboards, generator systems and critical electrical distribution networks.

Key Advantages

  • High-capacity 2000 A SACE Emax 2 air circuit breaker for demanding low-voltage power systems.
  • Advanced Ekip G Hi-Touch LSIG electronic trip unit for comprehensive protection and supervision.
  • 100 kA ultimate short-circuit breaking capacity at 400/415 V AC.
  • LSIG protection covers overload, short-time short-circuit, instantaneous short-circuit and earth-fault conditions.
  • Ekip G functionality is designed for advanced generator protection and power-system applications.
  • Three-pole fixed configuration for permanent switchboard installation.
  • Rear horizontal terminals support efficient integration with switchboard busbars and conductors.
  • Part of ABB's advanced SACE Emax 2 platform for intelligent electrical distribution and energy management.

Key Features

  • ABB SACE Emax 2 E2.2H frame.
  • 2000 A rated current.
  • Three-pole configuration.
  • Fixed mounting version.
  • Ekip G Hi-Touch LSIG electronic trip unit.
  • Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.
  • Advanced protection functions suitable for generator and critical power applications.
  • 100 kA Icu at 400/415 V AC.
  • 85 kA Ics at 400/415 V AC.
  • Designed for low-voltage systems with operating voltages up to 690 V AC.
  • Rear horizontal (HR) main terminals.
  • Advanced measurement, monitoring and communication capabilities through the Ekip platform.

Advanced Generator and Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 provide switching, isolation and fault protection for high-current low-voltage electrical networks. The E2.2H performance level is engineered for systems with high prospective fault currents, providing substantial interruption capability for main incomers, generator circuits, bus couplers and critical distribution feeders.

The Ekip G Hi-Touch LSIG trip unit combines adjustable LSIG overcurrent protection with advanced generator-oriented protection, measurement and supervision functions. This allows the breaker to support sophisticated power-generation and distribution architectures where protection selectivity, system monitoring, operational continuity and integration with intelligent electrical networks are important requirements.

Typical Applications

  • Generator protection and generator distribution switchboards.
  • Industrial low-voltage main distribution systems.
  • Main incomer and high-current feeder protection.
  • Power generation and standby power installations.
  • Data centres and critical electrical infrastructure.
  • Manufacturing and process-industry switchboards.
  • Transformer secondary distribution systems.
  • Power systems requiring LSIG protection and advanced electrical monitoring.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
ABB order code 1SDA071060R1
EAN 8015644749101
Product type Air circuit breaker
Rated current 2000 A
Number of poles 3
Trip unit Ekip G Hi-Touch LSIG
Protection functions L, S, I and G
Rated operational voltage up to 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 400/415 V AC 85 kA
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Current type AC
Installation Fixed
Terminal configuration Rear horizontal (HR)
Product net weight approx. 46 kg
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA071060R1?

The ABB 1SDA071060R1 is a SACE Emax 2 E2.2H fixed three-pole air circuit breaker rated at 2000 A and equipped with an Ekip G Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip G Hi-Touch LSIG trip unit provide?

The trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced functions intended for generator and critical power applications.

What is the current rating of the ABB E2.2H 1SDA071060R1?

The circuit breaker has a rated current of 2000 A.

What is the breaking capacity of the ABB E2.2H 2000?

The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 400/415 V AC and a service short-circuit breaking capacity of 85 kA at 400/415 V AC.

Is the ABB 1SDA071060R1 suitable for generator protection?

Yes. The Ekip G Hi-Touch trip unit is specifically suited to advanced generator and power-system protection applications, in addition to providing LSIG overcurrent protection.

Is the ABB 1SDA071060R1 fixed or withdrawable?

The 1SDA071060R1 is a fixed-version circuit breaker designed for permanent installation within a low-voltage switchboard.

What does FHR mean for the ABB 1SDA071060R1?

In this configuration, the circuit breaker is fixed and equipped with rear horizontal terminals, providing rear-facing connections for integration with switchboard busbars and conductors.

Where is the ABB E2.2H 2000 Ekip G Hi-Touch LSIG typically used?

It is suitable for generator systems, industrial main switchboards, critical infrastructure, high-current feeder circuits and other low-voltage installations requiring high breaking capacity, LSIG protection and advanced power-system supervision.

Trusted by Power Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers combine high-performance circuit protection with advanced measurement, control and power-management capabilities for demanding industrial, commercial, infrastructure and power-generation applications worldwide.