1SDA071055R1 ABB E2.2H 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker

1SDA071055R1 ABB E2.2H 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker

ABB 1SDA071055R1 Emax 2 E2.2H 2000 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Touch LSI electronic protection, 2000 A rated current, 690 V AC operational voltage and 100 kA breaking capacity at 380–440 V AC.

SKU: 1SDA071055R1MPN: 1SDA071055R1
Price
List Price £10,329.54 ex VAT
Your Price (ex VAT) Save 25%
£7,747.16 25% OFF
You save £2,582.39 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,747.16
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,747.16

Why Choose the ABB E2.2H 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker?

The ABB 1SDA071055R1, designated E2.2H 2000 Ekip Touch LSI 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for reliable switching, protection and monitoring in demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 2000 A rated current with the Ekip Touch LSI electronic trip unit for configurable overload and short-circuit protection.

The E2.2H configuration is engineered for industrial, commercial, infrastructure and critical-power installations where high current capacity, strong short-circuit performance and selective protection are required. Its Ekip Touch LSI electronic release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, with settings accessible through the touch-sensitive interface.

With a rated operational voltage of 690 V AC, rated ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and rated short-time withstand current of 85 kA for 1 s, the 1SDA071055R1 is designed for high-fault-level electrical networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals and is supplied with four auxiliary contacts and circuit-breaker open/closed position indication.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 2000 A rated current for high-current industrial and infrastructure applications.
  • 100 kA Icu at 380–440 V AC provides high short-circuit interruption capability.
  • 85 kA Icu at 500–690 V AC supports demanding higher-voltage distribution systems.
  • 85 kA short-time withstand current for 1 s supports selective protection strategies.
  • Ekip Touch LSI electronic trip unit provides long-time, short-time selective and instantaneous short-circuit protection.
  • 800–2000 A long-time overload adjustment range supports coordination with installation requirements.
  • Touch-sensitive interface provides convenient configuration of protection settings.
  • Supports compatible optional Ekip modules for communication, signalling and expanded system functionality.
  • Fixed three-pole construction with horizontal rear terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 2000 A rated current (In).
  • Three-pole configuration.
  • 690 V AC rated operational voltage (Ue).
  • 1000 V AC rated insulation voltage (Ui).
  • 12 kV rated impulse withstand voltage (Uimp).
  • 50/60 Hz operating frequency.
  • 100 kA rated ultimate short-circuit breaking capacity (Icu) at 380–440 V AC.
  • 85 kA rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC.
  • 85 kA rated short-time withstand current (Icw) for 1 s.
  • Ekip Touch LSI electronic protection release.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 0.4–1 × In long-time overload adjustment range.
  • 0.6–10 × In short-time selective protection adjustment range.
  • 1.5–15 × In instantaneous protection adjustment range.
  • Touch-sensitive interface for protection configuration.
  • Four auxiliary contacts and circuit-breaker open/closed position indication.

High-Performance Selective Protection for Low-Voltage Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage electrical systems. With a 2000 A current rating, 100 kA ultimate breaking capacity at 380–440 V AC and 85 kA short-time withstand capability for 1 s, this configuration is particularly suited to electrical networks with substantial prospective fault currents and demanding selectivity requirements.

The Ekip Touch LSI electronic trip unit combines long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. The adjustable short-time function helps coordinate upstream and downstream protective devices, while the Ekip Touch interface simplifies configuration and access to operating information. Compatible optional ABB Ekip modules can further extend communication, signalling and system-integration functionality where required.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Data centres and critical power installations.
  • Infrastructure electrical systems.
  • Transformer secondary distribution.
  • High-fault-level incoming supply protection.
  • High-current feeder protection requiring selective coordination.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071055R1
EAN 8015644749057
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker (ACB)
Frame E2.2H
Performance level H
Rated current (In) 2000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Frequency 50/60 Hz
Number of poles 3
Installation Fixed
Terminal configuration Horizontal rear terminals
Trip unit Ekip Touch LSI
Trip unit type Solid-state electronic protection release
Protection functions L, S, I
Long-time overload protection adjustment 0.4–1 × In (800–2000 A)
Short-time selective protection adjustment 0.6–10 × In (1200–20000 A)
Instantaneous short-circuit protection adjustment 1.5–15 × In (3000–30000 A)
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 212 W
Electrical durability at Ue ≤ 440 V 10000 cycles
Electrical durability at Ue 500–690 V 8000 cycles
Mechanical durability 25000 cycles
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071055R1 used for?

The ABB 1SDA071055R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits, particularly where high short-circuit performance and selective protection are required.

What is the current rating of the ABB E2.2H 2000?

The circuit breaker has a rated current of 2000 A, with long-time overload protection adjustable from 800–2000 A.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, with configurable protection settings accessible through its touch-sensitive interface.

What are the short-circuit ratings of the ABB 1SDA071055R1?

The E2.2H 2000 has a rated ultimate short-circuit breaking capacity of 100 kA at 380–440 V AC and 85 kA at 500–690 V AC, together with a rated short-time withstand current of 85 kA for 1 s.

What terminal configuration does the ABB 1SDA071055R1 use?

This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with configurable electronic protection, selective coordination and expandable system functionality to provide dependable switching and protection for demanding low-voltage electrical distribution systems.