1SDA071054R1 ABB E2.2H 2000 Ekip Touch LI 3p F HR Air Circuit Breaker

1SDA071054R1 ABB E2.2H 2000 Ekip Touch LI 3p F HR Air Circuit Breaker

ABB 1SDA071054R1 Emax 2 E2.2H 2000 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Touch LI electronic protection, 2000 A rated uninterrupted current, 100 kA breaking capacity at 440 V AC and 85 kA short-time withstand capability for 1 s.

SKU: 1SDA071054R1MPN: 1SDA071054R1
Price
List Price £9,920.23 ex VAT
Your Price (ex VAT) Save 25%
£7,440.17 25% OFF
You save £2,480.06 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,440.17
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,440.17

Why Choose the ABB E2.2H 2000 Ekip Touch LI 3p F HR Air Circuit Breaker?

The ABB 1SDA071054R1, designated E2.2H 2000 Ekip Touch LI 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for reliable switching, protection and monitoring in demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 2000 A rated uninterrupted current with the Ekip Touch LI electronic trip unit.

The E2.2H configuration is engineered for industrial, commercial, infrastructure and critical-power installations where high current capacity and strong short-circuit performance are required. Its Ekip Touch LI electronic release provides long-time overload (L) and instantaneous short-circuit (I) protection, while the touch interface provides convenient access to protection settings, measurements and operating information.

With a rated uninterrupted current of 2000 A, rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and rated short-time withstand current of 85 kA for 1 s, the 1SDA071054R1 is designed for high-fault-level electrical networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical configuration for permanent integration into low-voltage switchboards and switchgear assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 2000 A rated uninterrupted current for high-current industrial and infrastructure applications.
  • 100 kA Icu at 440 V AC provides high short-circuit interruption capability.
  • 85 kA short-time withstand current for 1 s supports demanding protection and selectivity requirements.
  • Ekip Touch LI electronic trip unit provides long-time overload and instantaneous short-circuit protection.
  • Touch interface simplifies access to protection settings, measurements and circuit-breaker information.
  • LI protection is well suited to distribution circuits requiring overload and high-current short-circuit protection.
  • Supports compatible optional Ekip modules for communication, signalling and expanded system functionality.
  • Fixed three-pole construction with horizontal rear terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 2000 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • E2.2H high-performance frame.
  • 100 kA rated ultimate short-circuit breaking capacity (Icu) at 440 V AC.
  • 85 kA rated short-time withstand current (Icw) for 1 s.
  • Ekip Touch LI electronic protection release.
  • Long-time overload (L) protection.
  • Instantaneous short-circuit (I) protection.
  • Ekip Touch interface for configuration and operating information.
  • Fixed circuit-breaker construction.
  • Horizontal rear terminal configuration.
  • Compatible with selected ABB Ekip accessories and expansion modules.

High-Performance Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage electrical systems. With a 2000 A rated uninterrupted current, 100 kA ultimate breaking capacity at 440 V AC and 85 kA short-time withstand capability for 1 s, this configuration is particularly suited to electrical networks with substantial prospective fault currents.

The Ekip Touch LI electronic trip unit combines long-time overload and instantaneous short-circuit protection with the Ekip Touch user interface. This LI configuration is suitable where dependable overload and high-current fault protection are required without integrated short-time or earth-fault protection, while compatible optional ABB Ekip modules can extend communication, signalling and monitoring functionality where required.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Data centres and critical power installations.
  • Infrastructure electrical systems.
  • Transformer secondary distribution.
  • High-fault-level incoming supply protection.
  • High-current feeder circuit protection.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071054R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker (ACB)
Frame E2.2H
Performance level H
Rated uninterrupted current (Iu) 2000 A
Number of poles 3
Installation Fixed
Terminal configuration Horizontal rear terminals
Trip unit Ekip Touch LI
Trip unit type Electronic protection release
Protection functions L, I
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 85 kA

Frequently Asked Questions

What is the ABB 1SDA071054R1 used for?

The ABB 1SDA071054R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage electrical distribution circuits, particularly where high short-circuit performance is required.

What is the current rating of the ABB E2.2H 2000?

The circuit breaker has a rated uninterrupted current of 2000 A, making it suitable for demanding high-current low-voltage distribution applications.

What protection does the Ekip Touch LI trip unit provide?

The Ekip Touch LI electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection, with a touch interface for accessing protection settings and operating information.

What are the short-circuit ratings of the ABB 1SDA071054R1?

The E2.2H 2000 has a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s.

What terminal configuration does the ABB 1SDA071054R1 use?

This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced electronic protection, flexible installation and expandable system functionality to provide dependable switching and protection for demanding low-voltage electrical distribution systems.