ABB 1SDA071053R1 Emax 2 E2.2H 2000 fixed three-pole air circuit breaker with Ekip Dip LSIG electronic protection, 2000 A rated current and 100 kA breaking capacity at 400–440 V AC.
£8,200.25
The ABB E2.2H 2000 Ekip Dip LSIG 3p FHR, order code 1SDA071053R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage AC power distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole breaker combines a 2000 A rated current with an Ekip Dip LSIG solid-state electronic trip unit.
The Ekip Dip LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. This comprehensive protection combination makes the breaker suitable for critical distribution systems where selective fault protection, dependable interruption and protection of cables, busbars and connected equipment are required.
The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 690 V AC. This model is supplied in a fixed three-pole configuration with rear flat horizontal terminals, four auxiliary contacts and circuit-breaker open/closed position indication for straightforward integration into high-current switchboards.
Air circuit breakers such as the ABB SACE Emax 2 provide switching and protection at critical points within low-voltage electrical networks. The E2.2H 2000 combines a high continuous-current rating with substantial short-circuit interruption and withstand capabilities, helping protect distribution equipment against overloads, short circuits and earth faults.
The Ekip Dip LSIG trip unit adds earth-fault protection to the long-time, short-time and instantaneous protection functions. This comprehensive protection arrangement makes the 1SDA071053R1 particularly suitable for engineered distribution systems where selective coordination, continuity of service and dependable isolation of different fault conditions are important.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA071053R1 |
| Product type | Air circuit breaker |
| Frame | E2.2 |
| Performance level | H |
| Rated current (In) | 2000 A |
| Rated uninterrupted current (Iu) | 2000 A |
| Current type | AC |
| Number of poles | 3 |
| Installation | Fixed |
| Trip unit | Ekip Dip LSIG |
| Release type | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and earth fault (LSIG) |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 85 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 85 kA |
| Service short-circuit breaking capacity (Ics) at 400–440 V AC | 100 kA |
| Service short-circuit breaking capacity (Ics) at 690 V AC | 85 kA |
| Ics as percentage of Icu | 100% |
| Rated short-time withstand current (Icw), 1 s | 85 kA |
| Rated short-time withstand current (Icw), 3 s | 66 kA |
| Main terminal position | Rear |
| Terminal configuration | Rear flat horizontal |
| Terminal type | Bolt |
| Main terminal tightening torque | 70 N·m |
| Connecting capacity | 1800 mm² |
| Auxiliary contacts | 4 |
| Suitable for IT networks | Yes, up to 690 V |
| Power loss | 212 W |
| Electrical durability | 10,000 cycles at Ue ≤ 440 V; 8,000 cycles at 500–690 V |
| Mechanical durability | 25,000 cycles |
| Dimensions (W × H × D) | 276 × 371 × 270 mm |
| Net weight | 41 kg |
| EAN | 8015644749033 |
| Standard | IEC 60947-2 |
The ABB 1SDA071053R1 is an Emax 2 E2.2H fixed three-pole air circuit breaker rated at 2000 A and equipped with an Ekip Dip LSIG electronic trip unit.
The Ekip Dip LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.
The E2.2H 2000 provides an ultimate short-circuit breaking capacity of 100 kA at 400–440 V AC and 85 kA at 690 V AC.
This model is a fixed three-pole air circuit breaker equipped with rear flat horizontal main terminals.
It is designed for high-current low-voltage distribution applications including industrial switchboards, main distribution panels, transformer secondary systems, infrastructure installations and OEM switchgear assemblies where comprehensive LSIG protection is required.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, comprehensive electronic protection and flexible switchboard integration for dependable low-voltage power distribution in demanding industrial, commercial and infrastructure installations.