ABB 1SDA071049R1 E2.2S 2000 Ekip Hi-Touch LSIG 3p F HR is a fixed three-pole 2000 A SACE Emax 2 air circuit breaker with 85 kA breaking capacity at 415 V AC and advanced LSIG electronic protection, measurement and monitoring.
£10,495.20
The ABB E2.2S 2000 Ekip Hi-Touch LSIG 3p F HR, order code 1SDA071049R1, is a high-performance air circuit breaker (ACB) designed for protection, control and isolation in demanding low-voltage electrical distribution systems. As part of the advanced ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 2000 A current rating with the Ekip Hi-Touch LSIG electronic trip unit for comprehensive circuit protection, measurement and monitoring.
The breaker incorporates LSIG protection functions, providing long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection. The Ekip Hi-Touch electronic release offers advanced protection and measurement capabilities, making the breaker particularly suitable for installations requiring precise coordination, selectivity and detailed supervision of the electrical distribution network.
With a rated current of 2000 A, a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 66 kA at 690 V AC, the E2.2S 2000 provides robust protection for substantial industrial and commercial distribution systems. This version features a fixed three-pole construction with rear horizontal terminals and is fitted with four auxiliary contacts and circuit-breaker open/closed position indication.
Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical distribution systems against overloads, short circuits and earth faults while providing reliable switching and isolation. The E2.2S performance level combines a substantial 2000 A current rating with high short-circuit capability, making the breaker suitable for main distribution boards, industrial switchboards and other critical high-current electrical installations.
The Ekip Hi-Touch LSIG electronic trip unit combines long-time overload, short-time delayed, instantaneous short-circuit and ground-fault protection with advanced measurement and monitoring capabilities. These functions support precise system coordination and allow electrical engineers to protect conductors, switchgear and connected equipment while maintaining detailed visibility of power-system operating conditions.
| Series | SACE Emax 2 |
|---|---|
| ABB product group | Emax2 Air Circuit Breaker |
| Frame | E2.2S |
| ABB order code / MPN | 1SDA071049R1 |
| Product type | Air circuit breaker |
| Rated current | 2000 A |
| Rated operational voltage | up to 690 V AC |
| Ultimate short-circuit breaking capacity (Icu) | 85 kA at 400–440 V AC; 66 kA at 500–690 V AC |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | LSIG |
| Long-time protection | Overload protection |
| Short-time protection | Delayed short-circuit protection |
| Instantaneous protection | Short-circuit protection |
| Earth-fault protection | Integrated |
| Short-circuit performance level | S |
| Installation version | Fixed |
| Main terminal orientation | Rear flat horizontal |
| Auxiliary contacts | 4 |
| Open/closed position indication | Yes |
| Dimensions (H × W × D) | 371 × 276 × 270 mm |
| Standards / approvals | IEC |
| Country of origin | Italy |
| EAN | 8015644748999 |
The ABB 1SDA071049R1 is an Emax 2 air circuit breaker designed to protect, control and isolate high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure applications.
The breaker has a rated current of 2000 A, making it suitable for substantial low-voltage power distribution circuits.
The E2.2S configuration provides an ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 66 kA at 690 V AC.
The Ekip Hi-Touch LSIG trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection together with advanced measurement and monitoring capabilities.
The 1SDA071049R1 is a fixed three-pole air circuit breaker with rear horizontal terminals for integration into low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers are designed for reliable protection, control and monitoring of low-voltage power distribution systems, combining high short-circuit performance with advanced electronic protection for demanding industrial and commercial installations.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.