1SDA071035R1 ABB E2.2N 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker

1SDA071035R1 ABB E2.2N 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker

ABB 1SDA071035R1 E2.2N 2000 Ekip Touch LSI 3p F HR is a fixed three-pole 2000 A SACE Emax 2 air circuit breaker with 66 kA short-circuit breaking capacity and adjustable LSI electronic protection.

SKU: 1SDA071035R1MPN: 1SDA071035R1
Price
List Price £8,789.86 ex VAT
Your Price (ex VAT) Save 25%
£6,592.40 25% OFF
You save £2,197.47 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,592.40
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,592.40

Why Choose the ABB E2.2N 2000 Ekip Touch LSI 3p F HR Air Circuit Breaker?

The ABB E2.2N 2000 Ekip Touch LSI 3p F HR, order code 1SDA071035R1, is a high-performance air circuit breaker (ACB) designed for protection, control and isolation in low-voltage electrical distribution systems. As part of the advanced ABB SACE Emax 2 series, this fixed three-pole circuit breaker combines a 2000 A current rating with the Ekip Touch LSI electronic trip unit for comprehensive overload and short-circuit protection.

The breaker incorporates LSI protection functions, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. The Ekip Touch electronic release provides configurable protection and an intuitive digital interface, supporting selective coordination and effective protection in demanding industrial and commercial electrical distribution systems.

With a rated uninterrupted current of 2000 A and an ultimate short-circuit breaking capacity of 66 kA for the E2.2N performance level, the 1SDA071035R1 is suited to substantial low-voltage distribution systems. This version features a fixed three-pole construction with rear horizontal terminals, providing a practical configuration for installation within switchboards and power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 2000 A rated current for high-current electrical installations.
  • 66 kA short-circuit breaking capacity for demanding distribution systems.
  • Advanced Ekip Touch LSI electronic trip unit for configurable circuit protection.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • Adjustable protection settings support selectivity and system coordination.
  • Fixed three-pole construction with rear horizontal terminals.
  • Designed for reliable protection of industrial, commercial and infrastructure power distribution systems.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 2000 A rated current.
  • Three-pole fixed air circuit breaker.
  • Ekip Touch LSI electronic protection release.
  • Long-time overload (L), short-time delayed (S) and instantaneous (I) protection.
  • 66 kA short-circuit breaking capacity for the E2.2N 2000 configuration.
  • Long-time protection adjustment range of 0.4–1 × In.
  • Short-time protection adjustment range of 0.6–10 × In.
  • Instantaneous protection adjustment range of 1.5–15 × In.
  • Rear horizontal main circuit connections.
  • Electronic trip technology for accurate and repeatable circuit protection.
  • Fixed installation design for switchboard and panel applications.

Advanced Circuit Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical distribution systems against overloads and short circuits while providing reliable switching and isolation. The E2.2N performance level combines a substantial 2000 A current rating with high short-circuit capability, making the breaker suitable for main distribution boards, industrial switchboards and other high-current electrical installations.

The Ekip Touch LSI electronic trip unit combines long-time overload, short-time delayed and instantaneous short-circuit protection. Its adjustable protection thresholds allow the breaker to be coordinated with upstream and downstream protective devices, helping engineers achieve effective selectivity while protecting conductors, switchgear and connected electrical equipment.

Typical Applications

  • Main low-voltage electrical distribution switchboards.
  • Industrial power distribution and manufacturing facilities.
  • Commercial buildings and infrastructure electrical systems.
  • Transformer secondary and distribution circuit protection.
  • High-current main incomer applications.
  • Feeder and distribution circuit protection.
  • High-fault-level electrical distribution installations.
  • OEM switchgear and electrical panel building.

Technical Specifications

Series SACE Emax 2
ABB product group Emax2 Air Circuit Breaker
Frame E2.2N
ABB order code / MPN 1SDA071035R1
Product type Air circuit breaker
Rated current 2000 A
Short-circuit breaking capacity 66 kA
Number of poles 3
Trip unit Ekip Touch LSI
Release type Electronic
Protection functions LSI
Long-time protection adjustment 0.4–1 × In
Short-time protection adjustment 0.6–10 × In
Instantaneous protection adjustment 1.5–15 × In
Installation version Fixed
Main terminal orientation Rear horizontal
Weight 46 kg
Country of origin Italy
EAN 8015644748852

Frequently Asked Questions

What is the ABB 1SDA071035R1 used for?

The ABB 1SDA071035R1 is an Emax 2 air circuit breaker designed to protect, control and isolate high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure applications.

What is the current rating of the ABB E2.2N 2000?

The breaker has a rated current of 2000 A, making it suitable for substantial low-voltage power distribution circuits.

What breaking capacity does the ABB 1SDA071035R1 provide?

The E2.2N 2000 configuration provides a short-circuit breaking capacity of 66 kA.

What protection functions are provided by the Ekip Touch LSI trip unit?

The Ekip Touch LSI trip unit provides long-time overload (L), short-time delayed short-circuit (S) and instantaneous short-circuit (I) protection.

Is the ABB 1SDA071035R1 a fixed or withdrawable circuit breaker?

The 1SDA071035R1 is a fixed three-pole air circuit breaker with rear horizontal terminals for integration into low-voltage switchboards.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are designed for reliable protection and control of low-voltage power distribution systems, combining high-current switching performance with advanced electronic protection for demanding industrial and commercial installations.