ABB 1SDA071025R1 E2.2B 2000 Ekip Touch LSI three-pole fixed SACE Emax 2 air circuit breaker rated at 2000 A with adjustable long-time, short-time and instantaneous electronic protection.
£6,256.19
The ABB E2.2B 2000 Ekip Touch LSI 3P, order code 1SDA071025R1, is a SACE Emax 2 air circuit breaker (ACB) designed for dependable protection and switching in high-current low-voltage electrical distribution systems. This fixed three-pole E2.2B breaker combines a rated uninterrupted current of 2000 A with ABB's Ekip Touch LSI solid-state electronic trip unit.
The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its electronic protection architecture and touchscreen interface support accurate configuration and selective coordination, helping protect cables, busbars, transformers and connected equipment while maintaining continuity of service.
The E2.2B performance level provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s. This configuration uses a fixed three-pole construction with rear horizontal terminals and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication.
ABB SACE Emax 2 air circuit breakers combine high-current switching capability with configurable electronic circuit protection for modern low-voltage networks. The E2.2B 2000 is well suited to main distribution boards, transformer-fed systems and high-current feeders where dependable interruption of overload and short-circuit conditions is required.
The Ekip Touch LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit functions. Short-time protection enables improved coordination between upstream and downstream protective devices, helping isolate a fault close to its source while reducing unnecessary interruption to unaffected sections of the electrical installation.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA071025R1 |
| EAN | 8015644748753 |
| Product type | Air circuit breaker (ACB) |
| Performance level | B |
| Rated uninterrupted current (Iu) | 2000 A |
| Rated operational voltage (Ue) | up to 690 V AC |
| Current type | AC |
| Number of poles | 3 |
| Trip unit | Ekip Touch LSI |
| Release type | Solid-state electronic |
| Protection functions | LSI (Long-time, Short-time, Instantaneous) |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated short-time withstand current (Icw), 1 s | 42 kA |
| Integrated ground-fault protection | No |
| Mounting | Fixed |
| Main terminals | Rear horizontal |
| Auxiliary contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Product width | 276 mm |
| Product height | 371 mm |
| Product depth | 270 mm |
| Product net weight | 45 kg |
| Mechanical durability | 25,000 cycles |
| Electrical durability at Ue ≤ 440 V | 10,000 cycles |
| Electrical durability at 500–690 V | 8,000 cycles |
| Standard | IEC 60947-2 |
The ABB 1SDA071025R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits against overload and short-circuit conditions.
The circuit breaker has a rated uninterrupted current of 2000 A.
The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.
The E2.2B 2000 provides an ultimate short-circuit breaking capacity of 42 kA at 440 V AC and a rated short-time withstand current of 42 kA for 1 s.
This fixed three-pole air circuit breaker uses rear horizontal terminals for integration into low-voltage switchboard and busbar systems.
ABB SACE Emax 2 air circuit breakers combine dependable high-current switching, configurable electronic protection and selective coordination capabilities to safeguard industrial, commercial and infrastructure low-voltage power distribution systems.