1SDA071019R1 ABB E2.2H 1600 Ekip Hi-Touch LSIG 3p FHR Air Circuit Breaker

1SDA071019R1 ABB E2.2H 1600 Ekip Hi-Touch LSIG 3p FHR Air Circuit Breaker

ABB 1SDA071019R1 Emax 2 E2.2H 1600 fixed three-pole air circuit breaker with Ekip Hi-Touch LSIG electronic protection, 1600 A rated current and 100 kA breaking capacity at 400 V AC.

SKU: 1SDA071019R1MPN: 1SDA071019R1
Price
List Price £12,103.05 ex VAT
Your Price (ex VAT) Save 25%
£9,077.29 25% OFF
You save £3,025.76 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,077.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,077.29

Why Choose the ABB E2.2H 1600 Ekip Hi-Touch LSIG 3p FHR Air Circuit Breaker?

The ABB E2.2H 1600 Ekip Hi-Touch LSIG 3p FHR, order code 1SDA071019R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection, monitoring and control of demanding low-voltage AC power distribution systems. Part of the advanced ABB Emax 2 E2.2 series, this fixed three-pole breaker combines a 1600 A rated current with the sophisticated Ekip Hi-Touch electronic trip unit.

The breaker incorporates comprehensive LSIG protection functions, providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection. The Ekip Hi-Touch electronic release supports advanced protection and monitoring functions, making this breaker well suited to industrial, commercial and infrastructure installations where dependable fault protection and power-system supervision are required.

With a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 100 kA at 400 V AC, the E2.2H 1600 is engineered for systems with high prospective fault currents. This version has a fixed three-pole configuration with rear horizontal terminals and is supplied with four auxiliary change-over contacts for circuit-breaker open/closed position signalling.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution.
  • 1600 A rated current for high-current electrical installations.
  • 100 kA ultimate short-circuit breaking capacity at 400 V AC.
  • Advanced Ekip Hi-Touch LSIG electronic protection release.
  • LSIG functions provide overload, short-time, instantaneous and earth-fault protection.
  • Fixed three-pole construction for permanent switchboard installation.
  • Rear horizontal terminals facilitate integration with switchboard busbar systems.
  • Four auxiliary change-over contacts provide circuit-breaker open/closed position signalling.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1600 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed installation version.
  • Ekip Hi-Touch LSIG electronic trip unit.
  • Long-time overload protection.
  • Short-time and instantaneous short-circuit protection.
  • Integrated earth-fault protection.
  • Rated operational voltage up to 690 V AC.
  • 100 kA Icu at 400 V AC.
  • Rear horizontal main terminals.
  • Four auxiliary change-over contacts for open/closed position indication.

Reliable LSIG Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 protect low-voltage electrical systems against abnormal current conditions while providing a dependable switching and isolation point within the distribution network. The E2.2H performance level provides substantial short-circuit interruption capability, making this breaker particularly suitable for switchboards where high prospective fault currents can occur.

The Ekip Hi-Touch LSIG trip unit extends protection beyond conventional overload and short-circuit functions by incorporating earth-fault protection. This combination enables comprehensive protection of conductors, equipment and distribution infrastructure while supporting selective coordination within sophisticated electrical networks.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and infrastructure electrical installations.
  • Manufacturing and process plant switchgear.
  • Power distribution centres and electrical substations.
  • High-current incomer and feeder protection.
  • Transformer and generator distribution systems.
  • Installations requiring integrated earth-fault protection.
  • OEM low-voltage switchboard assemblies.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA071019R1
Product type Air circuit breaker
Performance level H
Rated current 1600 A
Rated uninterrupted current (Iu) 1600 A
Current type AC
Number of poles 3
Installation Fixed
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and earth fault (LSIG)
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Service short-circuit breaking capacity (Ics) at 400 V AC 100 kA
Service short-circuit breaking capacity (Ics) at 690 V AC 85 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Overload release setting range 640–1600 A
Short-time short-circuit release adjustment range 960–16000 A
Instantaneous short-circuit release adjustment range 2400–24000 A
Main terminal position Rear
Terminal orientation Horizontal
Terminal connection type Rear flat horizontal
Main terminal type Bolt connection
Auxiliary contacts 4 change-over contacts
Dimensions 276 × 270 × 270 mm
EAN 8015644748692
Country of origin Italy
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA071019R1?

The ABB 1SDA071019R1 is an Emax 2 E2.2H fixed three-pole air circuit breaker rated at 1600 A and equipped with an Ekip Hi-Touch LSIG electronic trip unit.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The LSIG configuration provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.

What is the short-circuit breaking capacity of this breaker?

The E2.2H 1600 has an ultimate short-circuit breaking capacity of 100 kA at 400 V AC and 85 kA at 690 V AC.

Is the ABB E2.2H 1600 1SDA071019R1 fixed or withdrawable?

This model is a fixed three-pole air circuit breaker with rear horizontal main terminals.

Where is the ABB E2.2H 1600 typically used?

It is designed for high-current low-voltage distribution applications including industrial switchboards, main distribution panels, infrastructure systems, power distribution centres and OEM switchgear assemblies.

Trusted Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-performance fault interruption, advanced electronic protection and flexible system integration for dependable low-voltage power distribution in demanding industrial and commercial installations.