1SDA071015R1 ABB E2.2H 1600 Ekip Touch LSI 3P Air Circuit Breaker

1SDA071015R1 ABB E2.2H 1600 Ekip Touch LSI 3P Air Circuit Breaker

ABB 1SDA071015R1 E2.2H 1600 Ekip Touch LSI three-pole fixed SACE Emax 2 air circuit breaker rated at 1600 A with high-breaking-capacity long-time, short-time and instantaneous electronic protection.

SKU: 1SDA071015R1MPN: 1SDA071015R1
Price
List Price £7,737.41 ex VAT
Your Price (ex VAT) Save 25%
£5,803.06 25% OFF
You save £1,934.35 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,803.06
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,803.06

Why Choose the ABB E2.2H 1600 Ekip Touch LSI 3P Air Circuit Breaker?

The ABB E2.2H 1600 Ekip Touch LSI 3P, order code 1SDA071015R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage electrical distribution systems. This fixed three-pole E2.2H breaker combines a rated current of 1600 A with ABB's Ekip Touch LSI solid-state electronic trip unit.

The Ekip Touch LSI release provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection. Its touchscreen interface enables intuitive configuration and monitoring, while the short-time protection function supports selective coordination between upstream and downstream protective devices.

The high-performance E2.2H level provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s. This configuration is a fixed three-pole breaker with rear horizontal terminals and is fitted with four auxiliary contacts plus circuit-breaker open/closed position indication.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution systems.
  • 1600 A rated current for high-current industrial, commercial and infrastructure applications.
  • Ekip Touch LSI electronic trip unit provides adjustable overload and short-circuit protection.
  • Short-time delayed protection supports selective coordination between protective devices.
  • 100 kA ultimate short-circuit breaking capacity at 440 V AC.
  • 85 kA short-time withstand current for 1 s for demanding distribution networks.
  • Fixed three-pole construction with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2H frame.
  • 1600 A rated current.
  • Three-pole construction.
  • Fixed-mounted execution.
  • Rear horizontal main terminals.
  • Ekip Touch LSI solid-state electronic protection release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Touchscreen interface for intuitive protection configuration and monitoring.
  • High short-circuit interruption capability for demanding installations.
  • Four auxiliary contacts.
  • Circuit-breaker open/closed position indication.

High-Performance LSI Protection and Selectivity

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced electronic protection for modern low-voltage networks. The E2.2H 1600 is particularly suited to main distribution boards, transformer incomers and high-current feeders where high prospective fault currents require dependable interruption capability.

The Ekip Touch LSI release combines long-time overload protection with short-time delayed and instantaneous short-circuit functions. Short-time protection enables improved coordination between upstream and downstream protective devices, helping isolate faults close to their source while maintaining power to unaffected sections of the electrical installation.

Typical Applications

  • Main low-voltage electrical switchboards.
  • Industrial power distribution systems.
  • Commercial building electrical distribution.
  • Transformer incomer and secondary protection.
  • High-current feeder protection.
  • High-fault-level electrical installations.
  • Manufacturing and process facilities.
  • Data centres and critical infrastructure.
  • Distribution systems requiring selective short-circuit protection.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA071015R1
EAN 8015644748654
Product type Air circuit breaker (ACB)
Performance level H
Rated current 1600 A
Rated operational voltage up to 690 V AC
Number of poles 3
Current type AC
Trip unit Ekip Touch LSI
Release type Solid-state electronic
Protection functions LSI (Long-time, Short-time, Instantaneous)
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated short-time withstand current (Icw), 1 s 85 kA
Integrated ground-fault protection No
Mounting Fixed
Main terminals Rear horizontal
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Product net weight 46 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA071015R1 used for?

The ABB 1SDA071015R1 is an Emax 2 air circuit breaker designed for switching and protecting demanding low-voltage electrical distribution circuits against overload and short-circuit conditions.

What is the current rating of the ABB E2.2H 1600?

The circuit breaker has a rated current of 1600 A.

What protection functions does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the short-circuit performance of the ABB E2.2H 1600?

The E2.2H performance level provides an ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s.

What terminal configuration does the ABB 1SDA071015R1 use?

This fixed three-pole circuit breaker uses rear horizontal terminals for integration into low-voltage switchboard and busbar systems.

Trusted ABB Power Distribution Technology

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, selective coordination, robust switching and high short-circuit performance to safeguard demanding industrial, commercial and infrastructure low-voltage power distribution systems.