ABB 1SDA071009R1 E2.2S 1600 Ekip Hi-Touch LSIG three-pole fixed air circuit breaker with rear flat horizontal terminals, 1600 A rated current, 690 V AC rated operational voltage and 85 kA short-circuit breaking capacity at 400–440 V AC for advanced selective and ground-fault power distribution protection.
£8,624.20
The ABB E2.2S 1600 Ekip Hi-Touch LSIG 3p F HR, order code 1SDA071009R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for switching, isolation and protection in demanding low-voltage power distribution systems. Its E2.2S frame provides a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC, making it suitable for high-current industrial, commercial and infrastructure switchboards.
This model is equipped with an advanced Ekip Hi-Touch LSIG electronic trip unit, providing long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. The Hi-Touch platform combines comprehensive circuit protection with advanced measurement and monitoring capabilities, while the LSIG protection package supports selective coordination and detection of earth-fault conditions.
The E2.2S performance class provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. The 1SDA071009R1 is a three-pole fixed circuit breaker with rear flat horizontal terminals and is supplied with four auxiliary contacts plus open/closed circuit-breaker position indication for integration into compatible low-voltage switchgear.
Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage electrical networks. The E2.2S performance class combines a 1600 A current rating with 85 kA breaking capacity at 400–440 V AC and a 66 kA short-time withstand capability for 1 s, making it well suited to systems with substantial prospective fault currents.
The Ekip Hi-Touch LSIG trip unit provides comprehensive electronic protection. Long-time protection responds to sustained overloads, short-time protection supports selective coordination with downstream devices, instantaneous protection rapidly interrupts severe short circuits, and ground-fault protection detects potentially damaging earth-fault currents. This combination makes the 1SDA071009R1 particularly suitable for sophisticated distribution systems where selectivity, ground-fault protection and advanced monitoring are required.
| Series | SACE Emax 2 |
|---|---|
| Frame / sub-type | E2.2S |
| Order code / MPN | 1SDA071009R1 |
| EAN / GTIN | 8015644748593 |
| Product type | Air circuit breaker (ACB) |
| Current type | AC |
| Rated current | 1600 A |
| Rated uninterrupted current (Iu) | 1600 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 400–440 V AC |
| Rated service short-circuit breaking capacity (Ics) | 85 kA at 400–440 V AC |
| Ics as percentage of Icu | 100% |
| Rated short-time withstand current (Icw) | 66 kA for 1 s |
| Number of poles | 3 |
| Protection release | Ekip Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | L (long-time), S (short-time), I (instantaneous) and G (ground fault) |
| Integrated earth-fault protection | Yes |
| Short-circuit performance level | S |
| Mounting configuration | Fixed |
| Main circuit connection | Bolt connection |
| Connection position | Rear |
| Terminal arrangement | Rear flat horizontal |
| Recommended main-circuit screw | M12 |
| Terminal tightening torque | 70 N·m |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open / closed |
| Motor operator | Optional |
| Integrated motor operator | No |
| Degree of protection | IP30 |
| Power loss | 136 W |
| Electrical durability | 12,000 cycles at Ue ≤ 440 V AC |
| Mechanical durability | 25,000 cycles |
| Width | 276 mm |
| Depth | 270 mm |
| Approximate weight | 41 kg |
| Country of origin | Italy |
| Standard | IEC 60947-2 |
The ABB 1SDA071009R1 is an Emax 2 air circuit breaker designed for switching, isolation and protection of high-current low-voltage circuits, including main incomers, feeders, transformer secondary circuits and industrial power distribution systems.
The ABB E2.2S 1600 has a rated uninterrupted current of 1600 A and a rated operational voltage of 690 V AC.
The E2.2S performance class provides a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and 66 kA at 500–690 V AC. Its rated short-time withstand current is 66 kA for 1 s and 50 kA for 3 s.
The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection. This provides comprehensive protection while supporting selective coordination and advanced monitoring in demanding low-voltage distribution systems.
The F HR configuration identifies the product as a fixed circuit breaker with rear horizontal terminals. The 1SDA071009R1 uses rear flat horizontal bolted terminals for permanent integration into compatible low-voltage switchgear.
ABB SACE Emax 2 air circuit breakers are engineered for reliable switching, isolation and protection of modern low-voltage electrical systems, combining high short-circuit performance with advanced electronic protection, selective coordination, ground-fault protection and intelligent power monitoring capabilities.