1SDA071005R1 ABB E2.2S 1600 Ekip Touch LSI 3p F HR Air Circuit Breaker

1SDA071005R1 ABB E2.2S 1600 Ekip Touch LSI 3p F HR Air Circuit Breaker

ABB 1SDA071005R1 Emax 2 E2.2S 1600 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip Touch LSI electronic protection, 1600 A rated uninterrupted current and 85 kA breaking capacity at 400–440 V AC.

SKU: 1SDA071005R1MPN: 1SDA071005R1
Price
List Price £7,347.62 ex VAT
Your Price (ex VAT) Save 25%
£5,510.72 25% OFF
You save £1,836.91 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,510.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,510.72

Why Choose the ABB E2.2S 1600 Ekip Touch LSI 3p F HR Air Circuit Breaker?

The ABB 1SDA071005R1, designated E2.2S 1600 Ekip Touch LSI 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for reliable switching, protection and monitoring in demanding low-voltage power distribution systems. As part of the ABB SACE Emax 2 series, it combines a 1600 A rated uninterrupted current with the Ekip Touch LSI electronic trip unit for comprehensive overload and short-circuit protection.

The E2.2S is engineered for industrial, commercial and infrastructure installations where high breaking performance and selective electronic protection are required. Its Ekip Touch LSI release provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, allowing effective coordination between upstream and downstream protective devices within the electrical distribution system.

With a rated uninterrupted current of 1600 A, rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and rated short-time withstand current of 66 kA for 1 s, the 1SDA071005R1 provides robust protection for high-current distribution networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical arrangement for permanent integration into low-voltage switchboards and switchgear assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage power distribution.
  • 1600 A rated uninterrupted current for high-current industrial and commercial installations.
  • 85 kA Icu at 440 V AC provides high short-circuit interruption capability.
  • 66 kA short-time withstand current for 1 s supports selective protection strategies.
  • Ekip Touch LSI electronic trip unit provides overload, selective short-circuit and instantaneous short-circuit protection.
  • 640–1600 A long-time overload setting range supports coordination with installation requirements.
  • 960–16000 A short-time protection setting range provides adjustable selective short-circuit protection.
  • Ekip Touch interface provides convenient access to protection settings, measurements and operating information.
  • Fixed three-pole construction with horizontal rear terminals for permanent switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1600 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • 690 V AC rated operational voltage.
  • 85 kA rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 50 kA rated short-time withstand current (Icw) for 3 s.
  • Ekip Touch LSI electronic protection release.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • 640–1600 A long-time overload protection setting range.
  • 960–16000 A short-time protection setting range.
  • Ekip Touch interface for protection configuration, measurement and monitoring.
  • Fixed installation with horizontal rear terminals.

Advanced Selective Protection for High-Current Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage electrical distribution systems. With a 1600 A current rating, 85 kA ultimate breaking capacity at 400–440 V AC and 66 kA short-time withstand current for 1 s, this configuration is well suited to main distribution, transformer secondary and feeder circuits where dependable fault interruption and selective coordination are important.

The Ekip Touch LSI electronic trip unit combines long-time overload, short-time selective short-circuit and instantaneous short-circuit protection. The inclusion of adjustable short-time protection makes the LSI configuration particularly suitable for systems where discrimination between upstream and downstream protective devices is required, while the Ekip Touch platform provides convenient access to protection settings, measurements and operating information.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Infrastructure electrical systems.
  • Data centres and critical power installations.
  • Transformer secondary distribution.
  • High-current incoming supply protection.
  • Feeder protection requiring selective coordination.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA071005R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker (ACB)
Frame E2.2S
Performance level S
Rated uninterrupted current (Iu) 1600 A
Rated operational voltage 690 V AC
Number of poles 3
Installation Fixed
Terminal configuration Horizontal rear terminals
Trip unit Ekip Touch LSI
Trip unit type Electronic protection release
Protection functions L, S, I
Long-time overload protection setting range 640–1600 A
Short-time selective protection setting range 960–16000 A
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
EAN 8015644748555

Frequently Asked Questions

What is the ABB 1SDA071005R1 used for?

The ABB 1SDA071005R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage electrical distribution circuits against overloads and short circuits.

What is the current rating of the ABB E2.2S 1600?

The circuit breaker has a rated uninterrupted current of 1600 A, with a long-time overload protection setting range of 640–1600 A.

What protection does the Ekip Touch LSI trip unit provide?

The Ekip Touch LSI electronic trip unit provides long-time overload (L), short-time selective short-circuit (S) and instantaneous short-circuit (I) protection, making it suitable for distribution systems where selective coordination is required.

What are the short-circuit ratings of the ABB 1SDA071005R1?

The E2.2S 1600 has a rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC, together with a rated short-time withstand current of 66 kA for 1 s.

What terminal configuration does the ABB 1SDA071005R1 use?

This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high short-circuit performance, advanced electronic protection and selective coordination capabilities to provide dependable switching and protection for demanding low-voltage electrical distribution systems.