ABB 1SDA070997R1 Emax 2 E2.2N 1600 A three-pole fixed air circuit breaker with rear horizontal terminals, Ekip G Touch LSIG electronic protection and 66 kA ultimate breaking capacity at 400 V AC for demanding low-voltage power distribution and generator applications.
£7,981.02
The ABB E2.2N 1600 Ekip G Touch LSIG 3p F HR, order code 1SDA070997R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, engineered for protection, switching and power management in demanding low-voltage electrical distribution systems. Rated at 1600 A, this three-pole fixed breaker combines the E2.2N frame with ABB's advanced Ekip G Touch electronic protection technology.
The breaker incorporates an Ekip G Touch LSIG electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. The Ekip G Touch platform is designed for applications requiring advanced protection and power-management functionality, including generator and distribution-system applications where dependable coordination and comprehensive fault protection are essential.
The 3p F HR configuration identifies a three-pole fixed breaker with rear horizontal terminals. With a rated current of 1600 A, rated voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, the 1SDA070997R1 provides robust protection for high-current industrial, commercial and infrastructure distribution systems.
Air circuit breakers such as the ABB SACE Emax 2 E2.2N provide switching, isolation and electronic protection for high-current low-voltage installations. The Ekip G Touch platform extends these capabilities for demanding power-generation and distribution applications, combining configurable protection with monitoring and power-management functionality within the Emax 2 architecture.
The Ekip G Touch LSIG release combines long-time, short-time, instantaneous and ground-fault protection within a single advanced electronic protection unit. Together with its 1600 A rated current, 690 V AC rated voltage and 66 kA ultimate breaking capacity at 400 V AC, the 1SDA070997R1 provides a robust solution for high-current switchboards, generator installations and critical distribution feeders.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2N |
| ABB order code | 1SDA070997R1 |
| Product type | Air circuit breaker (ACB) |
| Rated current | 1600 A |
| Rated voltage | 690 V AC |
| Rated ultimate short-circuit breaking capacity at 400 V AC | 66 kA |
| Number of poles | 3 |
| Protection trip unit | Ekip G Touch LSIG |
| Trip-unit technology | Solid-state electronic release |
| Protection functions | Long-time, short-time, instantaneous and ground-fault (LSIG) |
| Overload release adjustment range | 640–1600 A |
| Short-time short-circuit release adjustment range | 960–16000 A |
| Instantaneous short-circuit release adjustment range | 2400–24000 A |
| Integrated ground-fault protection | Yes |
| Current type | AC |
| Installation | Fixed |
| Main-circuit terminals | Rear flat horizontal (HR) |
| Main-circuit connection | Bolt connection |
| Auxiliary contacts | 4 change-over contacts |
| Open/closed position indication | Yes |
| Integrated undervoltage release | No |
| Integrated motor drive | No |
| Motor drive | Optional |
| Dimensions (W × D) | 276 × 270 mm |
| Net weight | 41 kg |
| Country of origin | Italy |
| Product group | Emax2 Air Circuit Breaker |
The ABB 1SDA070997R1 is a SACE Emax 2 E2.2N 1600 Ekip G Touch LSIG 3p F HR air circuit breaker rated at 1600 A, with three-pole fixed construction, rear horizontal terminals and an Ekip G Touch LSIG electronic trip unit.
The breaker has a rated current of 1600 A, making it suitable for high-current low-voltage electrical distribution and generator applications.
The Ekip G Touch LSIG trip unit provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and ground-fault protection (G).
The E2.2N 1600 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, providing high fault-clearing capability for demanding low-voltage distribution systems.
Yes. The Ekip G Touch LSIG trip unit includes integrated ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.
The F HR designation identifies a fixed-version breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.
The 1SDA070997R1 is a fixed-version air circuit breaker, intended for permanent installation within a compatible low-voltage switchboard or distribution assembly.
ABB SACE Emax 2 air circuit breakers are engineered for reliable protection, switching and power management in low-voltage electrical distribution systems, supporting demanding industrial, commercial, infrastructure and power-generation installations.