1SDA070981R1 ABB E2.2B 1600 Ekip Dip LI 3p F HR Air Circuit Breaker 1600 A

1SDA070981R1 ABB E2.2B 1600 Ekip Dip LI 3p F HR Air Circuit Breaker 1600 A

ABB 1SDA070981R1 E2.2B 1600 Ekip Dip LI three-pole fixed air circuit breaker with rear horizontal terminals, 1600 A rated current and 42 kA short-circuit breaking capacity at 400–440 V AC for low-voltage power distribution protection.

SKU: 1SDA070981R1MPN: 1SDA070981R1
Price
List Price £5,768.94 ex VAT
Your Price (ex VAT) Save 25%
£4,326.71 25% OFF
You save £1,442.24 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,326.71
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,326.71

Why Choose the ABB E2.2B 1600 Ekip Dip LI 3p F HR Air Circuit Breaker?

The ABB E2.2B 1600 Ekip Dip LI 3p F HR, order code 1SDA070981R1, is a fixed air circuit breaker (ACB) from the ABB SACE Emax 2 range, designed for switching and protection in low-voltage power distribution systems. Its E2.2 frame provides a rated uninterrupted current of 1600 A, making it suitable for high-current feeders, incomers and main distribution circuits.

This model is equipped with an Ekip Dip LI solid-state electronic trip unit. It provides long-time overload (L) and instantaneous short-circuit (I) protection, giving straightforward electronic protection against sustained overcurrent and severe short-circuit faults without the additional short-time or ground-fault functions of LSI and LSIG variants.

The E2.2B performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 400–440 V AC. The 1SDA070981R1 is a three-pole fixed circuit breaker with rear horizontal terminals and is fitted with four auxiliary change-over contacts plus open/closed circuit-breaker position indication for integration into compatible switchgear.

Key Advantages

  • ABB SACE Emax 2 air circuit breaker for high-current low-voltage power distribution.
  • 1600 A rated uninterrupted current for demanding feeder and incomer applications.
  • 42 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • Ekip Dip LI electronic trip unit for overload and instantaneous short-circuit protection.
  • Adjustable long-time overload protection from 640–1600 A.
  • Adjustable instantaneous short-circuit protection from 2400–24000 A.
  • Three-pole fixed configuration with rear horizontal terminals.
  • Four auxiliary change-over contacts and open/closed position indication for switchgear integration.

Key Features

  • ABB SACE Emax 2 E2.2B series.
  • 1600 A rated uninterrupted current.
  • 690 V AC rated voltage.
  • Three-pole configuration.
  • Fixed mounting construction.
  • Rear horizontal terminals.
  • Ekip Dip LI solid-state electronic release.
  • Long-time overload (L) and instantaneous short-circuit (I) protection functions.
  • 42 kA Icu at 400–440 V AC.
  • Ics equal to 100% of Icu.
  • 42 kA rated short-time withstand current for 1 s.
  • Overload release adjustment range of 640–1600 A.
  • Instantaneous short-circuit release adjustment range of 2400–24000 A.
  • Four auxiliary change-over contacts.
  • Open/closed circuit-breaker position indication.
  • Optional motor operating mechanism.

LI Protection for 1600 A Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2B provide switching, isolation and protection for high-current low-voltage circuits. The E2.2B 1600 combines a 1600 A current rating with 42 kA short-circuit breaking capacity at 400–440 V AC, making it suitable for distribution boards where dependable high-current protection and fixed switchgear installation are required.

The Ekip Dip LI trip unit provides two fundamental electronic protection functions. Long-time protection responds to sustained overloads that could cause damaging thermal stress in cables and equipment, while instantaneous protection rapidly trips the breaker during severe short-circuit conditions. The adjustable settings allow the protection characteristics to be coordinated with the requirements of the protected circuit.

Typical Applications

  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Transformer secondary protection.
  • High-current feeder and incomer protection.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure electrical installations.
  • Building services and utility distribution boards.
  • Switchgear requiring 1600 A capacity with electronic LI protection.

Technical Specifications

Series SACE Emax 2
Frame / sub-type E2.2B
Order code / MPN 1SDA070981R1
EAN 8015644748319
Product type Air circuit breaker (ACB)
Current type AC
Rated current 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) 42 kA at 400–440 V AC
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw) 42 kA for 1 s
Number of poles 3
Protection release Ekip Dip LI
Release type Solid-state electronic
Protection functions L (long-time overload) and I (instantaneous short circuit)
Overload release adjustment range 640–1600 A
Instantaneous short-circuit release adjustment range 2400–24000 A
Integrated ground-fault protection No
Short-circuit performance level B
Mounting configuration Fixed
Terminal arrangement Rear horizontal
Auxiliary contacts 4 change-over contacts
Circuit-breaker position indication Open / closed
Motor operator Optional
Integrated motor operator No
Weight approx. 41 kg
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA070981R1 used for?

The ABB 1SDA070981R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage circuits, including main incomers, feeders, transformer secondary circuits and industrial power distribution systems.

What is the rated current of the ABB E2.2B 1600?

The ABB E2.2B 1600 has a rated uninterrupted current of 1600 A. Its Ekip Dip LI overload protection can be adjusted across a range of 640–1600 A.

What breaking capacity does the 1SDA070981R1 provide?

The E2.2B performance class provides a rated ultimate short-circuit breaking capacity of 42 kA at 400–440 V AC, with a rated short-time withstand current of 42 kA for 1 s.

What protection functions does the Ekip Dip LI trip unit provide?

The Ekip Dip LI solid-state electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection. The overload setting is adjustable from 640–1600 A, while the instantaneous short-circuit setting is adjustable from 2400–24000 A.

What does F HR mean on the ABB E2.2B 1600?

The F HR configuration identifies this product as a fixed circuit breaker with rear horizontal terminals, intended for permanent installation and rear connection within compatible low-voltage switchgear.

Trusted Power Distribution Technology from ABB

ABB SACE Emax 2 air circuit breakers are engineered for reliable switching and protection of modern low-voltage electrical systems, combining configurable electronic protection with robust short-circuit performance and flexible switchboard integration.