1SDA070977R1 ABB E2.2H 1250 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

1SDA070977R1 ABB E2.2H 1250 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA070977R1 Emax 2 E2.2H 1250 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip G Touch LSIG electronic protection and 1250 A rated uninterrupted current for demanding low-voltage distribution and generator applications.

SKU: 1SDA070977R1MPN: 1SDA070977R1
Price
List Price £11,479.40 ex VAT
Your Price (ex VAT) Save 25%
£8,609.55 25% OFF
You save £2,869.85 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,609.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,609.55

Why Choose the ABB E2.2H 1250 Ekip G Touch LSIG 3p F HR Air Circuit Breaker?

The ABB 1SDA070977R1, designated E2.2H 1250 Ekip G Touch LSIG 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for advanced protection, monitoring and control in demanding low-voltage power distribution and generator applications. As part of the ABB SACE Emax 2 series, it combines a 1250 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit.

The E2.2H is engineered for industrial, commercial, infrastructure and power-generation installations where high short-circuit breaking performance, selectivity and sophisticated electronic protection are required. Its Ekip G Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with generator-oriented protection, measurement and monitoring functionality.

With a rated uninterrupted current of 1250 A and the high-performance E2.2H frame, the 1SDA070977R1 is suited to electrical networks with substantial prospective fault currents. This configuration is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical arrangement for permanent integration into low-voltage switchboards and switchgear assemblies.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution and generator systems.
  • 1250 A rated uninterrupted current for high-current industrial and commercial installations.
  • E2.2H high-performance frame designed for electrical networks with substantial prospective short-circuit currents.
  • Ekip G Touch LSIG electronic trip unit combines comprehensive circuit protection with generator-oriented functionality.
  • LSIG protection covers overload, selective short-circuit, instantaneous short-circuit and earth-fault conditions.
  • Ekip Touch interface provides convenient access to protection settings, measurements and operating information.
  • Modular Ekip architecture supports compatible communication, signalling and power-management functionality.
  • Fixed three-pole construction with horizontal rear terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1250 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • Ekip G Touch LSIG electronic protection release.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated earth-fault (G) protection.
  • Generator-oriented protection and monitoring functionality.
  • Ekip Touch interface for configuration, measurement and operating information.
  • Fixed circuit-breaker construction.
  • Horizontal rear terminal configuration.
  • Expandable functionality through compatible ABB Ekip accessories and modules.

Advanced Generator and Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage electrical systems. The high-performance E2.2H frame is designed for demanding networks where substantial prospective fault currents and selective coordination requirements call for robust circuit-breaker performance.

The Ekip G Touch LSIG electronic trip unit combines long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection with functionality intended for generator and complex power-system applications. Its Ekip Touch interface provides access to protection settings and operating information, while the modular ABB Ekip platform supports compatible communication, signalling and power-management functions.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Data centres and critical power infrastructure.
  • Transformer and generator distribution systems.
  • High-fault-level incoming and feeder protection.
  • Energy management and industrial automation systems.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA070977R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker (ACB)
Frame E2.2H
Performance level H
Rated uninterrupted current (Iu) 1250 A
Number of poles 3
Installation Fixed
Terminal configuration Horizontal rear terminals
Trip unit Ekip G Touch LSIG
Trip unit type Electronic protection release
Protection functions L, S, I, G
Earth-fault protection Integrated
Interface Ekip Touch
Application focus Power distribution and generator protection

Frequently Asked Questions

What is the ABB 1SDA070977R1 used for?

The ABB 1SDA070977R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage power distribution and generator systems.

What is the current rating of the ABB E2.2H 1250?

The circuit breaker has a rated uninterrupted current of 1250 A, making it suitable for high-current low-voltage distribution and generator applications.

What protection does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with generator-oriented protection and monitoring functionality.

What does the E2.2H designation mean?

The E2.2H designation identifies the Emax 2 frame and its high-performance breaking-capacity level, intended for demanding low-voltage networks with substantial prospective fault currents.

What terminal configuration does the ABB 1SDA070977R1 use?

This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high-performance circuit interruption with advanced electronic protection, measurement and expandable connectivity capabilities to provide dependable protection and intelligent power management for demanding low-voltage distribution and generator systems.