ABB 1SDA070956R1 E2.2N 1250 Ekip Touch LSIG three-pole fixed SACE Emax 2 air circuit breaker rated at 1250 A with long-time, short-time, instantaneous and ground-fault protection for low-voltage power distribution.
£5,306.08
The ABB E2.2N 1250 Ekip Touch LSIG 3P, order code 1SDA070956R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection, control and switching in demanding low-voltage electrical distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole circuit breaker combines a rated uninterrupted current of 1250 A with the advanced Ekip Touch LSIG solid-state electronic trip unit.
The Ekip Touch LSIG release provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This comprehensive electronic protection package supports accurate settings and selective coordination, helping protect cables, busbars, transformers and connected equipment against phase and earth-fault conditions while maintaining continuity of service.
The E2.2N performance level provides an ultimate short-circuit breaking capacity of 66 kA across key operating voltages up to 690 V AC, with service breaking capacity equal to 100% of Icu. This configuration is a fixed three-pole breaker with rear flat horizontal terminals and includes four auxiliary changeover contacts plus circuit-breaker open/closed position indication.
ABB SACE Emax 2 air circuit breakers are engineered to provide dependable switching and protection for demanding low-voltage electrical networks. The E2.2N frame combines substantial short-circuit performance with high short-time withstand capability, making it suitable for main switchboards, transformer incomers, industrial distribution assemblies and high-current feeder circuits.
The Ekip Touch LSIG electronic release combines long-time overload, short-time delayed, instantaneous and ground-fault protection. The inclusion of short-time and ground-fault functions supports selective coordination and comprehensive system protection, helping isolate faults while maintaining electrical service to unaffected sections of the installation.
| Series | SACE Emax 2 E2.2 |
|---|---|
| ABB order code | 1SDA070956R1 |
| EAN | 8015644748067 |
| Product type | Air circuit breaker (ACB) |
| Performance level | N |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated voltage (Ur) | 690 V |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Trip unit | Ekip Touch LSIG |
| Release type | Electronic solid-state |
| Protection functions | LSIG (Long-time, Short-time, Instantaneous, Ground fault) |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 525 V AC | 66 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 66 kA |
| Service short-circuit breaking capacity (Ics) | 100% of Icu |
| Rated short-time withstand current (Icw), 1 s | 66 kA |
| Rated short-time withstand current (Icw), 3 s | 50 kA |
| Integrated ground-fault protection | Yes |
| Mounting | Fixed |
| Main terminals | Rear flat horizontal |
| Terminal type | Bolt |
| Main terminal tightening torque | 70 N·m |
| Auxiliary changeover contacts | 4 |
| Position indication | Circuit breaker open / closed |
| Power loss | 83 W |
| Mechanical durability | 25,000 cycles |
| Electrical durability | 15,000 cycles |
| Standard | IEC 60947-2 |
The ABB 1SDA070956R1 is an Emax 2 air circuit breaker designed for switching and protecting low-voltage electrical distribution circuits against overload, short-circuit and ground-fault conditions.
The circuit breaker has a rated uninterrupted current of 1250 A.
The Ekip Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection.
The E2.2N 1250 provides an ultimate short-circuit breaking capacity of 66 kA at key operating voltages from 400 V AC through to 690 V AC.
This fixed three-pole circuit breaker uses rear flat horizontal terminals with bolted main-circuit connections for integration into low-voltage switchboard and busbar systems.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection with robust switching, selective coordination and high short-circuit performance to safeguard modern industrial, commercial and infrastructure low-voltage power distribution systems.