1SDA070954R1 ABB E2.2N 1250 Ekip Touch LI 3p FHR Air Circuit Breaker

1SDA070954R1 ABB E2.2N 1250 Ekip Touch LI 3p FHR Air Circuit Breaker

ABB 1SDA070954R1 Emax 2 E2.2N 1250 fixed three-pole air circuit breaker with rear horizontal terminals, a 1250 A rated uninterrupted current, Ekip Touch LI electronic trip unit and 66 kA ultimate short-circuit breaking capacity at 415 V AC.

SKU: 1SDA070954R1MPN: 1SDA070954R1
Price
List Price £5,905.35 ex VAT
Your Price (ex VAT) Save 25%
£4,429.01 25% OFF
You save £1,476.34 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,429.01
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,429.01

Why Choose the ABB E2.2N 1250 Ekip Touch LI 3p FHR Air Circuit Breaker?

The ABB E2.2N 1250 Ekip Touch LI 3p FHR, order code 1SDA070954R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection, switching and management of low-voltage electrical distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole circuit breaker combines a 1250 A rated uninterrupted current with an Ekip Touch LI solid-state electronic trip unit and rear horizontal terminals.

The Ekip Touch LI electronic release provides long-time overload and instantaneous short-circuit protection, combining configurable electronic protection with the advanced interface and measurement capabilities of the Ekip Touch platform. This LI configuration is particularly suitable for distribution circuits requiring dependable overload and high-current short-circuit protection without integrated short-time selective or earth-fault protection functions.

With a rated uninterrupted current of 1250 A, a rated operational voltage up to 690 V AC and an E2.2N breaking capacity of 66 kA at 415 V AC, the ABB 1SDA070954R1 provides robust protection for substantial electrical loads. Its fixed three-pole construction with rear horizontal terminals provides an effective connection arrangement for permanent integration into industrial, commercial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1250 A rated uninterrupted current for substantial electrical loads.
  • 66 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Advanced Ekip Touch LI electronic trip unit.
  • LI protection functions covering long-time overload and instantaneous short-circuit protection.
  • Adjustable overload protection across 500–1250 A.
  • Instantaneous protection adjustable across a broad multiple of rated current.
  • Fixed three-pole construction with rear horizontal terminals for switchboard integration.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1250 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • Three-pole configuration.
  • Fixed version for permanent switchboard installation.
  • Rear flat horizontal terminal arrangement.
  • Ekip Touch LI solid-state electronic release.
  • Long-time overload protection (L).
  • Instantaneous short-circuit protection (I).
  • 66 kA breaking capacity at 415 V AC.
  • Four auxiliary contacts with open/closed circuit-breaker position indication.
  • Designed for integration into modern low-voltage distribution and energy-management systems.

Advanced LI Protection for Low-Voltage Power Distribution

The ABB SACE Emax 2 E2.2N is designed for switching and protection in high-current low-voltage distribution systems. Its 1250 A current rating and 66 kA breaking capacity at 415 V AC make it suitable for main distribution circuits, feeders and other applications where substantial load currents and prospective short-circuit levels must be managed safely.

The Ekip Touch LI trip unit provides long-time overload and instantaneous short-circuit protection. The long-time function protects cables, busbars and connected equipment against sustained overcurrents, while the instantaneous function responds rapidly to severe short-circuit conditions. This LI configuration provides straightforward electronic overcurrent protection where short-time selective and integrated earth-fault functions are not required.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Commercial and large-building electrical distribution.
  • Manufacturing plants and process facilities.
  • Transformer secondary distribution systems.
  • Infrastructure and utility installations.
  • Data centres and critical power distribution.
  • Main incomer and high-current feeder circuits.
  • Electrical switchgear and panel building.

Technical Specifications

Series SACE Emax 2
Frame E2.2N
Product ID / order code 1SDA070954R1
Product group Emax2 Air Circuit Breaker
Product type Air circuit breaker
Rated uninterrupted current (Iu) 1250 A
Rated operational voltage up to 690 V AC
Number of poles 3
Version Fixed
Terminal arrangement Rear flat horizontal
Trip unit Ekip Touch LI
Release type Solid-state electronic
Protection functions LI
Overload protection setting range 500–1250 A
Instantaneous protection setting 1.5–15 × In
Short-time selective protection Not included
Integrated earth-fault protection No
Rated ultimate short-circuit breaking capacity (Icu) 66 kA at 415 V AC
Auxiliary contacts 4
Breaker position indication Open / closed
Product width 276 mm
Product depth 270 mm
Product net weight 46 kg
Standards / approvals IEC
Country of origin Italy
EAN 8015644748043

Frequently Asked Questions

What is the ABB 1SDA070954R1 used for?

The ABB 1SDA070954R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution circuits in industrial, commercial, infrastructure and critical power applications.

What is the rated current of the ABB E2.2N 1250?

The E2.2N 1250 Ekip Touch LI has a rated uninterrupted current of 1250 A, with long-time overload protection adjustable across 500–1250 A.

What is the breaking capacity of the ABB E2.2N 1250?

The E2.2N 1250 has a rated ultimate short-circuit breaking capacity of 66 kA at 415 V AC.

What protection does the Ekip Touch LI trip unit provide?

The Ekip Touch LI electronic trip unit provides long-time overload and instantaneous short-circuit protection. This LI configuration does not include integrated short-time selective or earth-fault protection.

What does FHR mean on the ABB E2.2N 1250?

For the ABB 1SDA070954R1 configuration, FHR identifies a fixed air circuit breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.

Trusted for High-Current Power Distribution

ABB SACE Emax 2 air circuit breakers combine dependable switching, high short-circuit performance and advanced electronic protection, providing a flexible solution for demanding industrial, commercial, infrastructure and critical low-voltage distribution systems.