1SDA070947R1 ABB E2.2H 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker 1000 A

1SDA070947R1 ABB E2.2H 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker 1000 A

ABB 1SDA070947R1 E2.2H 1000 Ekip G Touch LSIG three-pole fixed air circuit breaker with rear horizontal terminals, 1000 A rated current and 100 kA short-circuit breaking capacity at 415 V AC for advanced generator and low-voltage power distribution protection.

SKU: 1SDA070947R1MPN: 1SDA070947R1
Price
List Price £11,265.02 ex VAT
Your Price (ex VAT) Save 25%
£8,448.77 25% OFF
You save £2,816.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,448.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,448.77

Why Choose the ABB E2.2H 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E2.2H 1000 Ekip G Touch LSIG 3p F HR, order code 1SDA070947R1, is a high-performance air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this E2.2 frame circuit breaker combines a rated uninterrupted current of 1000 A with high H-class short-circuit performance for industrial, commercial, infrastructure and power-generation applications.

The breaker is equipped with an Ekip G Touch LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. The Ekip G Touch platform adds generator-oriented protection functionality to the advanced Ekip Touch interface, making this model particularly suitable for generator-fed networks and installations requiring comprehensive electrical protection, measurement and monitoring.

The E2.2H performance class provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 85 kA at 690 V AC. The 1SDA070947R1 is a three-pole fixed circuit breaker with rear horizontal terminals and is supplied with four auxiliary change-over contacts, providing a robust solution for permanent integration into compatible low-voltage switchgear.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for demanding power distribution and generator applications.
  • 1000 A rated uninterrupted current for high-current electrical systems.
  • 100 kA ultimate short-circuit breaking capacity at 415 V AC.
  • 85 kA ultimate short-circuit breaking capacity at 690 V AC.
  • Advanced Ekip G Touch LSIG electronic trip unit with generator-oriented functionality.
  • Provides long-time, short-time, instantaneous and ground-fault protection.
  • Three-pole fixed configuration with rear horizontal terminals.
  • Four auxiliary change-over contacts for integration with switchgear control and indication circuits.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1000 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • Three-pole configuration.
  • Fixed mounting design.
  • Rear flat horizontal terminals.
  • Ekip G Touch LSIG solid-state electronic release.
  • Long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection functions.
  • 100 kA Icu at 415 V AC.
  • 85 kA Icu at 690 V AC.
  • Overload protection adjustment range of 400–1000 A.
  • Short-time delayed short-circuit adjustment range of 600–10000 A.
  • Instantaneous short-circuit adjustment range of 1500–15000 A.
  • Integrated ground-fault protection.
  • Four auxiliary change-over contacts.
  • Optional motor operating mechanism.
  • IP30 degree of protection.

Advanced Generator and LSIG Protection for Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage electrical circuits. The H-performance version of the E2.2 frame is designed for installations with particularly high prospective short-circuit currents, providing 100 kA breaking capacity at 415 V AC and retaining 85 kA capability at 690 V AC.

The Ekip G Touch LSIG trip unit combines generator-oriented functionality with comprehensive LSIG protection. Long-time protection responds to sustained overloads, short-time protection supports selective fault coordination, instantaneous protection rapidly interrupts severe short circuits, and ground-fault protection detects potentially damaging earth faults. This combination makes the 1SDA070947R1 particularly suitable for generator-fed networks and critical low-voltage power systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage distribution switchboards.
  • Industrial power distribution systems.
  • Critical and standby power systems.
  • Transformer and installation protection.
  • Manufacturing and process plant switchgear.
  • High-current feeder and incomer protection.
  • Electrical installations requiring advanced LSIG protection and high short-circuit performance.

Technical Specifications

Series SACE Emax 2
Frame / sub-type E2.2H
Order code / MPN 1SDA070947R1
EAN 8015644747978
Product type Air circuit breaker (ACB)
Current type AC
Rated current 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) 100 kA at 415 V AC
Number of poles 3
Protection release Ekip G Touch LSIG
Release type Solid-state electronic
Protection functions L (long-time), S (short-time), I (instantaneous) and G (ground fault)
Overload protection adjustment range 400–1000 A
Short-time delayed short-circuit adjustment range 600–10000 A
Instantaneous short-circuit adjustment range 1500–15000 A
Integrated ground-fault protection Yes
Short-circuit performance level H
Mounting configuration Fixed
Terminal arrangement Rear horizontal
Terminal type Rear flat horizontal
Main circuit connection Bolt connection
Auxiliary contacts 4 change-over contacts
Circuit-breaker position indication Open / closed
Motor operator Optional
Degree of protection IP30
Power loss 53 W
Dimensions 270 × 276 × 270 mm
Weight approx. 41 kg
Country of origin Italy
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA070947R1 used for?

The ABB 1SDA070947R1 is an Emax 2 air circuit breaker designed for generator, transformer and installation protection in demanding high-current low-voltage electrical distribution systems.

What is the rated current of the ABB E2.2H 1000?

The ABB E2.2H 1000 has a rated uninterrupted current of 1000 A and is designed for low-voltage systems operating at up to 690 V AC.

What breaking capacity does the 1SDA070947R1 provide?

The E2.2H performance class provides a rated ultimate short-circuit breaking capacity of 100 kA at 415 V AC and 85 kA at 690 V AC, making it suitable for installations with high prospective fault currents.

What protection functions does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and ground-fault (G) protection, together with functionality intended for generator protection applications.

What does F HR mean on the ABB E2.2H 1000?

The F HR configuration identifies this model as a fixed circuit breaker with rear horizontal terminals, designed for permanent installation and rear connection within compatible low-voltage switchgear.

Trusted Power Distribution Technology from ABB

ABB SACE Emax 2 air circuit breakers are engineered for reliable protection, switching and management of modern low-voltage electrical systems, combining high short-circuit performance with advanced electronic protection, generator functionality and flexible switchboard integration.