1SDA070943R1 ABB E2.2H 1000 Ekip Dip LSIG 3p FHR Air Circuit Breaker

1SDA070943R1 ABB E2.2H 1000 Ekip Dip LSIG 3p FHR Air Circuit Breaker

ABB 1SDA070943R1 Emax 2 E2.2H 1000 air circuit breaker, a fixed three-pole 1000 A ACB with horizontal rear terminals and Ekip Dip LSIG electronic overload, short-circuit and earth-fault protection.

SKU: 1SDA070943R1MPN: 1SDA070943R1
Price
List Price £7,795.87 ex VAT
Your Price (ex VAT) Save 25%
£5,846.90 25% OFF
You save £1,948.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,846.90
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,846.90

Why Choose the ABB E2.2H 1000 Ekip Dip LSIG 3p FHR Air Circuit Breaker?

The ABB E2.2H 1000 Ekip Dip LSIG 3p FHR, order code 1SDA070943R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in demanding low-voltage AC power distribution systems. Part of the ABB Emax 2 E2.2 series, it combines a 1000 A current rating with the high-breaking-capacity E2.2H performance class and an Ekip Dip electronic trip unit.

This model is a fixed, three-pole circuit breaker with horizontal rear terminals equipped with an Ekip Dip LSIG solid-state electronic release. Its LSIG protection functions provide long-time overload, short-time delayed short-circuit, instantaneous short-circuit and earth-fault protection, delivering comprehensive protection for cables, busbars, transformers and connected distribution equipment.

With a rated uninterrupted current of 1000 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 100 kA at 400/415/440 V AC, the E2.2H 1000 is engineered for systems with very high prospective fault currents. Its 85 kA short-time withstand rating for 1 s, four auxiliary change-over contacts and open/closed position indication make it well suited to critical industrial and infrastructure switchboards.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2H air circuit breaker.
  • 1000 A rated uninterrupted current for high-current low-voltage distribution.
  • Ekip Dip LSIG electronic trip unit provides comprehensive configurable protection.
  • LSIG functionality combines overload, short-time, instantaneous and earth-fault protection.
  • 100 kA Icu at 400/415/440 V AC provides robust interruption of very high prospective fault currents.
  • 85 kA Icw for 1 s supports selective protection in demanding distribution networks.
  • Fixed three-pole construction with horizontal rear terminals suits direct switchboard busbar integration.
  • Four auxiliary change-over contacts support signalling, monitoring and control integration.

Key Features

  • ABB SACE Emax 2 E2.2H series.
  • 1000 A rated uninterrupted current.
  • Three-pole configuration.
  • Fixed version.
  • Horizontal rear flat terminals.
  • Ekip Dip LSIG solid-state electronic release.
  • Long-time L overload protection.
  • Short-time delayed S short-circuit protection.
  • Instantaneous I short-circuit protection.
  • Integrated G earth-fault protection.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 100 kA Icu at 400/415/440 V AC.
  • 85 kA Icu at 500/525/690 V AC.
  • Ics equal to 100% of Icu.
  • 85 kA Icw for 1 s.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.

Advanced Selective and Earth-Fault Protection for High-Fault Systems

Air circuit breakers such as the ABB Emax 2 E2.2H protect low-voltage electrical networks by automatically interrupting current when hazardous overload, short-circuit or earth-fault conditions occur. The Ekip Dip LSIG electronic release combines long-time, short-time delayed, instantaneous and ground-fault functions, providing comprehensive protection for distribution systems where both overcurrent coordination and earth-fault detection are required.

The E2.2H performance class combines a 100 kA ultimate breaking capacity at 400/415/440 V AC with an 85 kA 1-second short-time withstand capability. Its fixed construction and horizontal rear terminals facilitate integration with switchboard busbars, making the 1SDA070943R1 particularly suitable for main incomers, high-current feeders and distribution systems exposed to substantial prospective fault currents.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Selective electrical distribution systems.
  • Applications requiring integrated earth-fault protection.
  • Installations with high prospective short-circuit currents.
  • Transformer secondary distribution switchboards.
  • Manufacturing and process plant switchgear.
  • Commercial and critical infrastructure power distribution.
  • OEM switchboards requiring horizontal rear busbar connections.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA070943R1
EAN 8015644747930
Product type Air circuit breaker
Frame / performance class E2.2H
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Version Fixed
Terminal arrangement Rear flat horizontal
Main-circuit connection Bolt connection
Trip unit Ekip Dip LSIG electronic release
Release type Electronic (EL)
Protection functions L (long-time overload), S (short-time short circuit), I (instantaneous short circuit), G (earth fault)
Integrated earth-fault protection Yes
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 525 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 85 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 85 kA
Rated short-time withstand current (Icw), 3 s 66 kA
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Control element Push button
Complete device with protection unit Yes
Integrated motor drive No
Optional motor drive Yes
Integrated undervoltage release No
DIN rail mounting No
Degree of protection IP30
Electrical durability at Ue ≤ 440 V 15000 cycles
Electrical durability at 500–690 V 15000 cycles
Mechanical durability 25000 cycles
Standard IEC

Frequently Asked Questions

What is the ABB 1SDA070943R1 used for?

The ABB 1SDA070943R1 is an Emax 2 E2.2H air circuit breaker designed for switching and protecting high-current low-voltage AC distribution circuits, particularly systems requiring high short-circuit performance and integrated earth-fault protection.

What is the rated current of the E2.2H 1000 Ekip Dip LSIG?

The circuit breaker has a rated uninterrupted current of 1000 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Dip LSIG trip unit provide?

The Ekip Dip LSIG electronic trip unit provides long-time overload (L), short-time delayed short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the breaking capacity of the ABB E2.2H 1000?

The E2.2H 1000 has a rated ultimate short-circuit breaking capacity of 100 kA at 400/415/440 V AC and 85 kA at 500/525/690 V AC, with an Ics rating equal to 100% of Icu.

What does FHR mean on the ABB 1SDA070943R1?

The FHR configuration identifies a fixed circuit breaker with horizontal rear terminals, providing a connection arrangement particularly suited to integration with busbars inside low-voltage switchboards.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, high short-circuit performance and flexible switchboard integration to provide dependable protection and selective control for demanding low-voltage power distribution systems.