ABB 1SDA070940R1 Emax 2 E2.2S 1000 fixed three-pole air circuit breaker with rear horizontal terminals, a 1000 A rated uninterrupted current, Ekip G Hi-Touch LSIG generator-oriented electronic trip unit, 85 kA ultimate breaking capacity at 415 V AC and 66 kA short-time withstand current for 1 s.
£8,668.01
The ABB E2.2S 1000 Ekip G Hi-Touch LSIG 3p FHR, order code 1SDA070940R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for generator protection and demanding low-voltage power distribution systems. Part of the ABB Emax 2 E2.2 series, this fixed three-pole circuit breaker combines a 1000 A rated uninterrupted current with an advanced Ekip G Hi-Touch LSIG electronic trip unit and rear horizontal terminals.
The Ekip G Hi-Touch platform provides advanced generator-oriented protection, measurement and monitoring capabilities for applications where dependable protection and detailed supervision of electrical parameters are required. Its LSIG functions provide long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection, supporting comprehensive protection and selective coordination within generator and distribution systems.
With a rated uninterrupted current of 1000 A, a rated voltage of 690 V and an E2.2S breaking capacity of 85 kA at 415 V AC, the ABB 1SDA070940R1 is engineered for substantial fault levels. The E2.2S frame also provides a rated short-time withstand current of 66 kA for 1 s, while its fixed three-pole construction and rear horizontal terminals support efficient integration into low-voltage switchboards and generator distribution assemblies.
The ABB Ekip G Hi-Touch platform extends the protection and supervision capabilities of the SACE Emax 2 range for generator and power-generation applications. Generator-fed systems can have operating and fault characteristics that differ from utility-fed networks, making dedicated generator-oriented protection valuable for maintaining stability, coordinating protective devices and safeguarding generating equipment.
The Ekip G Hi-Touch LSIG trip unit combines these generator-oriented capabilities with long-time overload, short-time selective, instantaneous short-circuit and earth-fault protection. Together with the E2.2S frame's 85 kA breaking capacity at 415 V AC and 66 kA short-time withstand capability, this makes the ABB 1SDA070940R1 well suited to generator switchboards, standby power systems, industrial generation and critical low-voltage distribution.
| Series | SACE Emax 2 |
|---|---|
| Frame | E2.2S |
| Product ID / order code | 1SDA070940R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated voltage | 690 V |
| Number of poles | 3 |
| Version | Fixed |
| Terminal arrangement | Rear horizontal |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | LSIG |
| Integrated earth-fault protection | Yes |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 415 V AC |
| Rated short-time withstand current (Icw) | 66 kA for 1 s |
| Overload release setting range | 400–1000 A |
| Short-time delayed short-circuit setting range | 600–10000 A |
| Instantaneous short-circuit setting range | 1500–15000 A |
| Auxiliary contacts | 4 change-over contacts |
| Breaker position indication | Open / closed |
| Motor operator | Optional |
The ABB 1SDA070940R1 is an Emax 2 air circuit breaker designed for generator protection and demanding low-voltage power distribution, making it suitable for generator switchboards, industrial systems, standby power installations and critical electrical infrastructure.
The E2.2S 1000 Ekip G Hi-Touch LSIG has a rated uninterrupted current of 1000 A, with an overload release setting range of 400–1000 A.
The E2.2S 1000 has a rated ultimate short-circuit breaking capacity of 85 kA at 415 V AC and 66 kA at 690 V AC, together with a rated short-time withstand current of 66 kA for 1 s.
The Ekip G Hi-Touch LSIG electronic trip unit provides advanced generator-oriented protection and monitoring together with long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection.
For the ABB 1SDA070940R1 configuration, FHR identifies a fixed air circuit breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.
ABB SACE Emax 2 air circuit breakers combine high short-circuit performance with advanced electronic protection and power management capabilities, while Ekip G Hi-Touch technology provides enhanced functionality for generator, standby power and critical low-voltage distribution applications.