1SDA070937R1 ABB E2.2S 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

1SDA070937R1 ABB E2.2S 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA070937R1 Emax 2 E2.2S 1000 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip G Touch LSIG electronic protection, 1000 A rated uninterrupted current, 690 V AC operational voltage and 85 kA breaking capacity at 400–440 V AC.

SKU: 1SDA070937R1MPN: 1SDA070937R1
Price
List Price £10,699.79 ex VAT
Your Price (ex VAT) Save 25%
£8,024.84 25% OFF
You save £2,674.95 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,024.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,024.84

Why Choose the ABB E2.2S 1000 Ekip G Touch LSIG 3p F HR Air Circuit Breaker?

The ABB 1SDA070937R1, designated E2.2S 1000 Ekip G Touch LSIG 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for advanced protection, monitoring and control in low-voltage power distribution and generator applications. As part of the ABB SACE Emax 2 series, it combines a 1000 A rated uninterrupted current with the Ekip G Touch LSIG electronic trip unit for comprehensive electrical protection and power-system management.

The E2.2S is engineered for demanding industrial, commercial, infrastructure and power-generation installations where high breaking capacity, selectivity and advanced electronic protection are required. Its Ekip G Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with generator-oriented protection functions, measurement and monitoring capabilities.

With a rated uninterrupted current of 1000 A, rated operational voltage up to 690 V AC, rated ultimate short-circuit breaking capacity of 85 kA at 400–440 V AC and rated short-time withstand current of 66 kA for 1 s, the 1SDA070937R1 provides robust protection for demanding electrical networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for low-voltage distribution and generator applications.
  • 1000 A rated uninterrupted current for high-current industrial and commercial installations.
  • 85 kA Icu at 400–440 V AC provides high short-circuit breaking performance.
  • 66 kA short-time withstand current for 1 s supports selective protection strategies.
  • Ekip G Touch LSIG electronic trip unit combines comprehensive circuit protection with generator-oriented functionality.
  • Touchscreen interface supports intuitive configuration, measurement and monitoring.
  • Expandable Ekip architecture supports integration with automation and energy-management systems.
  • Fixed three-pole construction with horizontal rear terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E2.2S series.
  • 1000 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage (Ui).
  • 12 kV rated impulse withstand voltage (Uimp).
  • 85 kA rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC.
  • 66 kA Icu at 500–690 V AC.
  • 66 kA rated short-time withstand current (Icw) for 1 s.
  • 50 kA rated short-time withstand current (Icw) for 3 s.
  • Ekip G Touch LSIG electronic protection release.
  • Long-time overload (L) protection.
  • Short-time selective short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • Integrated earth-fault (G) protection.
  • Generator-oriented protection and monitoring functionality.
  • Touchscreen interface for configuration and operating information.
  • Fixed installation with horizontal rear terminals.

Advanced Generator and Power Distribution Protection

Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage electrical systems. The E2.2S performance level combines high short-circuit interruption capability with strong short-time withstand performance, supporting selective coordination between protective devices and helping maintain continuity of supply to unaffected circuits.

The Ekip G Touch LSIG electronic trip unit combines long-time overload, short-time selective short-circuit, instantaneous short-circuit and earth-fault protection with advanced functionality for generator and power-system applications. Its touchscreen interface provides convenient access to protection settings, measurements and operating information, while the modular Ekip architecture supports integration with compatible communication, signalling and energy-management systems.

Typical Applications

  • Generator protection and generator switchboards.
  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial building power distribution.
  • Data centres and critical power infrastructure.
  • Transformer and generator distribution systems.
  • High-current incoming and feeder protection.
  • Energy management and industrial automation systems.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA070937R1
Product type Air circuit breaker (ACB)
Frame E2.2S
Short-circuit performance level S
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Installation Fixed
Terminal configuration Horizontal rear terminals
Trip unit Ekip G Touch LSIG
Trip unit type Electronic release
Protection functions L, S, I, G
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 85 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 66 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) 100% of Icu
Rated short-time withstand current (Icw), 1 s 66 kA
Rated short-time withstand current (Icw), 3 s 50 kA
Earth-fault protection Integrated
Auxiliary contacts 4
Position indication Circuit breaker open / closed
Power loss 53 W
Suitable for IT networks Yes, up to 690 V
Dimensions (H × W × D) approx. 270 × 276 × 270 mm
EAN 8015644747879
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA070937R1 used for?

The ABB 1SDA070937R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage power distribution and generator systems.

What is the current rating of the ABB E2.2S 1000?

The circuit breaker has a rated uninterrupted current of 1000 A.

What protection does the Ekip G Touch LSIG trip unit provide?

The Ekip G Touch LSIG electronic trip unit provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with generator-oriented protection, measurement and monitoring functionality.

What is the breaking capacity of the ABB 1SDA070937R1?

The E2.2S 1000 has a rated ultimate short-circuit breaking capacity (Icu) of 85 kA at 400–440 V AC, with an Icu of 66 kA at 690 V AC.

What terminal configuration does the ABB 1SDA070937R1 use?

This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB

ABB SACE Emax 2 air circuit breakers combine high breaking performance, advanced electronic protection, measurement and connectivity capabilities to provide dependable protection and intelligent power management for demanding low-voltage distribution and generator systems.