ABB 1SDA070931R1 E2.2S 1000 Ekip Dip LI three-pole fixed air circuit breaker with rear horizontal terminals, 1000 A rated current and 85 kA short-circuit breaking capacity at 440 V AC for high-current low-voltage power distribution protection.
£4,750.59
The ABB E2.2S 1000 Ekip Dip LI 3p F HR, order code 1SDA070931R1, is a high-performance air circuit breaker (ACB) designed for protection and switching in demanding low-voltage power distribution systems. Part of the ABB SACE Emax 2 series, this E2.2 frame circuit breaker combines a 1000 A rated current with high short-circuit breaking performance for industrial, commercial and infrastructure electrical installations.
The breaker is equipped with an Ekip Dip LI solid-state electronic trip unit, providing long-time overload (L) and instantaneous short-circuit (I) protection. This protection combination provides dependable circuit protection without the additional short-time or ground-fault functions found on LSI and LSIG variants, making it suitable for applications where straightforward electronic overload and instantaneous fault protection is required.
The E2.2S performance class provides a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and 66 kA at 690 V AC. The 1SDA070931R1 is a three-pole fixed circuit breaker with rear horizontal terminals and is supplied with four auxiliary contacts plus circuit-breaker open/closed position indication for integration into compatible switchgear assemblies.
Air circuit breakers such as the ABB SACE Emax 2 E2.2S provide switching, isolation and protection for high-current low-voltage electrical circuits. The E2.2S performance class is designed for installations with substantial prospective short-circuit currents, offering 85 kA breaking capacity at 440 V AC while retaining strong performance at higher operating voltages.
The Ekip Dip LI electronic trip unit provides two fundamental protection functions. Long-time protection responds to sustained overload conditions that could cause excessive heating in cables and equipment, while instantaneous protection rapidly trips the circuit breaker when a severe short circuit is detected. This combination makes the 1SDA070931R1 suitable for applications requiring dependable electronic protection without short-time delayed or ground-fault protection functions.
| Series | SACE Emax 2 |
|---|---|
| Frame / sub-type | E2.2S |
| Order code / MPN | 1SDA070931R1 |
| EAN | 8015644747817 |
| Product type | Air circuit breaker (ACB) |
| Current type | AC |
| Rated current | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational voltage | up to 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) | 85 kA at 440 V AC |
| Rated short-time withstand current (Icw) | 66 kA for 1 s |
| Number of poles | 3 |
| Protection release | Ekip Dip LI |
| Release type | Solid-state electronic |
| Protection functions | L (long-time overload) and I (instantaneous short circuit) |
| Short-circuit performance level | S |
| Mounting configuration | Fixed |
| Terminal arrangement | Rear horizontal |
| Auxiliary contacts | 4 |
| Circuit-breaker position indication | Open / closed |
| Approximate weight | 41 kg |
| Standard | IEC 60947-2 |
The ABB 1SDA070931R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage circuits, including transformer, generator, feeder and general electrical distribution applications.
The ABB E2.2S 1000 has a rated uninterrupted current of 1000 A, making it suitable for high-current low-voltage power distribution systems.
The E2.2S performance class provides a rated ultimate short-circuit breaking capacity of 85 kA at 440 V AC and 66 kA at 690 V AC.
The Ekip Dip LI solid-state electronic trip unit provides long-time overload (L) and instantaneous short-circuit (I) protection, protecting the electrical circuit against sustained overloads and severe short-circuit faults.
The F HR configuration identifies the circuit breaker as a fixed-mounting version with rear horizontal terminals, designed for permanent installation and rear connection within compatible low-voltage switchgear.
ABB SACE Emax 2 air circuit breakers are designed for reliable switching and protection of modern low-voltage electrical distribution systems, combining high short-circuit performance with electronic protection and flexible switchboard integration.