1SDA070928R1 ABB E2.2N 1000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

1SDA070928R1 ABB E2.2N 1000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker

ABB 1SDA070928R1 Emax 2 E2.2N 1000 air circuit breaker, a fixed three-pole 1000 A ACB with horizontal rear terminals and Ekip Hi-Touch LSI electronic overload, short-time and instantaneous short-circuit protection.

SKU: 1SDA070928R1MPN: 1SDA070928R1
Price
List Price £9,881.26 ex VAT
Your Price (ex VAT) Save 25%
£7,410.95 25% OFF
You save £2,470.32 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,410.95
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,410.95

Why Choose the ABB E2.2N 1000 Ekip Hi-Touch LSI 3p FHR Air Circuit Breaker?

The ABB E2.2N 1000 Ekip Hi-Touch LSI 3p FHR, order code 1SDA070928R1, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for advanced protection and switching in demanding low-voltage AC power distribution systems. Part of the ABB Emax 2 E2.2 series, this configuration combines a 1000 A rating with the E2.2N performance class and the sophisticated Ekip Hi-Touch electronic trip unit.

This model is a fixed, three-pole circuit breaker with horizontal rear terminals and an Ekip Hi-Touch LSI solid-state electronic release. Its LSI protection functions provide long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection, allowing precise coordination of cables, busbars, transformers and downstream distribution equipment.

With a rated uninterrupted current of 1000 A, rated operational voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, the E2.2N 1000 provides robust protection for high-current distribution systems. Four auxiliary change-over contacts, open/closed position indication and optional motorised operation support integration into modern switchboard control and automation systems.

Key Advantages

  • High-performance ABB SACE Emax 2 E2.2N air circuit breaker.
  • 1000 A rated uninterrupted current for substantial low-voltage distribution loads.
  • Ekip Hi-Touch LSI electronic trip unit provides advanced configurable overcurrent protection.
  • LSI functionality combines long-time, short-time delayed and instantaneous short-circuit protection.
  • 66 kA Icu at 400 V AC provides robust interruption of high prospective fault currents.
  • 400–1000 A adjustable overload setting supports protection coordination.
  • Fixed three-pole construction with horizontal rear terminals suits switchboard busbar integration.
  • Four auxiliary change-over contacts support signalling, monitoring and automation.

Key Features

  • ABB SACE Emax 2 E2.2N series.
  • 1000 A rated current.
  • Three-pole configuration.
  • Fixed version.
  • Horizontal rear terminals.
  • Ekip Hi-Touch LSI solid-state electronic release.
  • Long-time L overload protection.
  • Short-time delayed S short-circuit protection.
  • Instantaneous I short-circuit protection.
  • 400–1000 A overload release adjustment range.
  • 600–10000 A short-time delayed short-circuit adjustment range.
  • 1500–15000 A instantaneous short-circuit adjustment range.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage.
  • 12 kV rated impulse withstand voltage.
  • 66 kA Icu at 400 V AC.
  • Four auxiliary change-over contacts.
  • Circuit-breaker open/closed position indication.

Advanced Selective Protection for Power Distribution

Air circuit breakers such as the ABB Emax 2 E2.2N protect low-voltage electrical networks by automatically interrupting current when hazardous overload or short-circuit conditions occur. The Ekip Hi-Touch LSI electronic release provides independently configurable long-time, short-time delayed and instantaneous protection functions, supporting selective coordination while protecting conductors, busbars and connected equipment.

The E2.2N platform combines 66 kA short-circuit performance with advanced electronic protection and a robust Emax 2 construction. Horizontal rear terminals facilitate connection to switchboard busbars, while auxiliary contacts, status indication and optional motor operation make the 1SDA070928R1 well suited to sophisticated industrial and infrastructure distribution systems.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power distribution systems.
  • Main incomer and high-current feeder protection.
  • Selective electrical distribution systems.
  • Transformer secondary distribution switchboards.
  • Manufacturing and process plant switchgear.
  • Commercial and infrastructure power distribution.
  • Switchboards requiring horizontal rear busbar connections.
  • OEM switchboards and automated power-distribution systems.

Technical Specifications

Series SACE Emax 2 E2.2
ABB order code 1SDA070928R1
EAN 8015644747787
Product type Air circuit breaker
Frame / performance class E2.2N
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated operational voltage (Ue) 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Rated impulse withstand voltage (Uimp) 12 kV
Number of poles 3
Version Fixed
Terminal arrangement Horizontal rear terminals
Main-circuit connection Bolt connection
Trip unit Ekip Hi-Touch LSI electronic release
Protection functions L (long-time overload), S (short-time short circuit), I (instantaneous short circuit)
Integrated earth-fault protection No
Overload release setting 400–1000 A
Short-time delayed short-circuit setting 600–10000 A
Instantaneous short-circuit setting 1500–15000 A
Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz 66 kA
Rated service short-circuit breaking capacity (Ics) at 400 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) at 440 V AC 66 kA
Rated service short-circuit breaking capacity (Ics) at 500 V AC 66 kA
Auxiliary contacts 4 change-over contacts
Position indication Circuit breaker open / closed
Control element Push button
Protection unit Integrated
Integrated motor drive No
Optional motor drive Yes
Integrated undervoltage release No
DIN rail mounting No
Degree of protection IP30
Electrical durability at Ue ≤ 440 V 15000 cycles
Electrical durability at 500–690 V 15000 cycles
Mechanical durability 25000 cycles
Power loss 53 W
Dimensions (W × H × D) 371 × 276 × 270 mm
Standard / approval IEC

Frequently Asked Questions

What is the ABB 1SDA070928R1 used for?

The ABB 1SDA070928R1 is an Emax 2 E2.2N air circuit breaker designed for switching and protecting high-current low-voltage AC distribution circuits, including main incomers, feeders and industrial distribution systems requiring selective electronic protection.

What is the rated current of the E2.2N 1000 Ekip Hi-Touch LSI?

The circuit breaker has a rated uninterrupted current of 1000 A and a rated operational voltage of up to 690 V AC.

What protection does the Ekip Hi-Touch LSI trip unit provide?

The Ekip Hi-Touch LSI electronic trip unit provides long-time overload (L), short-time delayed short-circuit (S) and instantaneous short-circuit (I) protection. This model does not include integrated G earth-fault protection.

What is the breaking capacity of the ABB E2.2N 1000?

The E2.2N 1000 has a rated ultimate short-circuit breaking capacity of 66 kA at 400 V AC, 50 Hz, providing robust fault interruption for demanding low-voltage distribution systems.

What does FHR mean on the ABB 1SDA070928R1?

The FHR configuration identifies a fixed circuit breaker with horizontal rear terminals, providing a connection arrangement particularly suited to integration with switchboard busbar systems.

Trusted ABB Protection for Critical Power Systems

ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, robust short-circuit performance and flexible switchboard integration to provide dependable protection and selective control for modern low-voltage power distribution systems.