ABB 1SDA070920R1 Emax 2 E2.2H 800 fixed three-pole air circuit breaker with horizontal rear terminals, Ekip G Hi-Touch LSIG electronic protection, 800 A rated uninterrupted current, 690 V AC rated voltage and 100 kA breaking capacity at 400 V AC.
£9,033.47
The ABB 1SDA070920R1, designated E2.2H 800 Ekip G Hi-Touch LSIG 3p F HR, is a high-performance three-pole air circuit breaker (ACB) designed for advanced protection, monitoring and control of low-voltage power distribution and generator systems. As part of the ABB SACE Emax 2 series, it combines an 800 A rated uninterrupted current with the advanced Ekip G Hi-Touch LSIG electronic trip unit.
The E2.2H is engineered for demanding industrial, commercial, infrastructure and power-generation installations requiring very high short-circuit breaking performance and sophisticated protection. Its Ekip G Hi-Touch LSIG release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced generator protection, measurement and power-management functionality.
With a rated uninterrupted current of 800 A, rated voltage of 690 V AC and rated ultimate short-circuit breaking capacity of 100 kA at 400 V AC, the 1SDA070920R1 provides robust protection for critical electrical networks. This version is a fixed, three-pole circuit breaker with horizontal rear terminals, providing a practical connection arrangement for integration into low-voltage switchboards and switchgear assemblies.
Air circuit breakers such as the ABB SACE Emax 2 E2.2H provide switching, isolation and protection for high-current low-voltage electrical systems. The high-performance E2.2H frame is particularly suited to installations with substantial prospective fault currents, providing up to 100 kA short-circuit breaking capacity at 400 V AC while supporting selective coordination across complex electrical distribution networks.
The Ekip G Hi-Touch LSIG electronic trip unit combines comprehensive LSIG circuit protection with advanced functionality for generator and power-system applications. The Ekip platform supports sophisticated measurement, monitoring and communication capabilities and can be integrated with compatible automation and energy-management networks, making the breaker suitable for modern intelligent power distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Order code / MPN | 1SDA070920R1 |
| Product type | Air circuit breaker (ACB) |
| Frame | E2.2H |
| Rated uninterrupted current (Iu) | 800 A |
| Rated voltage | 690 V AC |
| Number of poles | 3 |
| Installation | Fixed |
| Terminal configuration | Horizontal rear terminals |
| Main circuit connection | Bolt connection |
| Trip unit | Ekip G Hi-Touch LSIG |
| Trip unit type | Solid-state electronic release |
| Protection functions | L, S, I, G |
| Overload release current setting | 320 A |
| Short-time delayed short-circuit release setting | 480 A |
| Instantaneous short-circuit release setting | 1200 A |
| Rated ultimate short-circuit breaking capacity (Icu) at 400 V AC, 50 Hz | 100 kA |
| Earth-fault protection | Integrated |
| Auxiliary contacts | 4 change-over contacts |
| Motor operator | Optional |
| Protection rating | IP30 |
| Power loss | 34 W |
| Control element | Push button |
| Standard | IEC 60947-2 |
| Net weight | 45 kg |
| Country of origin | Italy |
| EAN | 8015644747701 |
The ABB 1SDA070920R1 is an Emax 2 air circuit breaker designed for switching, protecting and monitoring high-current low-voltage power distribution and generator systems.
The circuit breaker has a rated uninterrupted current of 800 A.
The Ekip G Hi-Touch LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, together with advanced generator protection, measurement and monitoring functionality.
The E2.2H 800 has a rated ultimate short-circuit breaking capacity (Icu) of 100 kA at 400 V AC, 50 Hz, making it suitable for demanding installations with high prospective fault currents.
This version is a fixed three-pole air circuit breaker with horizontal rear terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.
ABB SACE Emax 2 air circuit breakers combine high short-circuit breaking performance with advanced electronic protection, measurement and connectivity capabilities to provide dependable protection and intelligent power management for demanding low-voltage distribution and generator systems.