1SDA070919R1 ABB E2.2H 800 Ekip Hi-Touch LSIG 3p F HR Air Circuit Breaker

1SDA070919R1 ABB E2.2H 800 Ekip Hi-Touch LSIG 3p F HR Air Circuit Breaker

ABB 1SDA070919R1 Emax 2 E2.2H 800 A three-pole fixed air circuit breaker with rear horizontal terminals, Ekip Hi-Touch LSIG electronic protection and 100 kA ultimate breaking capacity at 440 V AC for demanding low-voltage power distribution systems.

SKU: 1SDA070919R1MPN: 1SDA070919R1
Price
List Price £11,440.42 ex VAT
Your Price (ex VAT) Save 25%
£8,580.32 25% OFF
You save £2,860.11 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,580.32
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,580.32

Why Choose the ABB E2.2H 800 Ekip Hi-Touch LSIG 3p F HR Air Circuit Breaker?

The ABB E2.2H 800 Ekip Hi-Touch LSIG 3p F HR, order code 1SDA070919R1, is a high-performance air circuit breaker (ACB) from the ABB SACE Emax 2 range, engineered for protection, switching and isolation in demanding low-voltage electrical distribution systems. Rated at 800 A, this three-pole fixed breaker combines the high-breaking-capacity E2.2H frame with ABB's advanced Ekip Hi-Touch electronic protection platform.

The breaker incorporates an Ekip Hi-Touch LSIG solid-state electronic trip unit, providing long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection. This comprehensive protection arrangement supports effective coordination while protecting cables, busbars, transformers and connected equipment against a broad range of electrical fault conditions.

The 3p F HR configuration identifies a three-pole fixed breaker with rear horizontal terminals. The E2.2H frame provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s, making the 1SDA070919R1 particularly suitable for high-fault-level switchboards and critical distribution applications.

Key Advantages

  • High-performance 800 A air circuit breaker for demanding low-voltage power distribution.
  • Ekip Hi-Touch LSIG electronic trip unit provides comprehensive overload, short-circuit and ground-fault protection.
  • 100 kA rated ultimate short-circuit breaking capacity at 440 V AC.
  • 85 kA rated short-time withstand current for 1 s supports demanding selective distribution systems.
  • Three-pole fixed construction for permanent switchboard installation.
  • Rear horizontal terminals provide a practical rear connection arrangement for switchgear integration.
  • Advanced Hi-Touch functionality supports sophisticated protection, measurement and power-management requirements.
  • Integrated ground-fault protection provides additional protection for low-voltage distribution networks.

Key Features

  • ABB SACE Emax 2 E2.2H air circuit breaker.
  • 800 A rated current.
  • 3-pole configuration.
  • 100 kA Icu at 440 V AC.
  • 85 kA Icw for 1 s.
  • Ekip Hi-Touch LSIG solid-state electronic release.
  • Long-time overload protection (L).
  • Short-time short-circuit protection (S).
  • Instantaneous short-circuit protection (I).
  • Integrated ground-fault protection (G).
  • Fixed installation with rear horizontal terminals.
  • Fitted with 4 auxiliary contacts.
  • Breaker open/closed position indication.

Advanced Protection for High-Fault-Level Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E2.2H protect high-current low-voltage installations against overloads, short circuits and ground faults while providing controlled switching and isolation. The Ekip Hi-Touch electronic platform combines advanced protection capabilities with measurement and power-management functionality, supporting effective coordination and management of sophisticated electrical distribution networks.

The Ekip Hi-Touch LSIG release combines long-time, short-time, instantaneous and ground-fault protection within a single electronic trip unit. Together with its 800 A current rating, 100 kA ultimate breaking capacity at 440 V AC and 85 kA short-time withstand capability for 1 s, the 1SDA070919R1 provides a robust protection solution for demanding high-fault-level installations.

Typical Applications

  • Low-voltage main distribution switchboards.
  • High-fault-level industrial distribution systems.
  • Commercial and infrastructure power distribution.
  • Incoming mains and high-current feeder protection.
  • Transformer secondary distribution circuits.
  • Manufacturing and process-industry switchboards.
  • Critical power-distribution installations.
  • Distribution networks requiring advanced LSIG electronic protection.

Technical Specifications

Series SACE Emax 2
Frame E2.2H
ABB order code 1SDA070919R1
Product type Air circuit breaker (ACB)
Rated current 800 A
Number of poles 3
Rated ultimate short-circuit breaking capacity at 440 V AC 100 kA
Rated short-time withstand current for 1 s 85 kA
Protection trip unit Ekip Hi-Touch LSIG
Trip-unit technology Solid-state electronic release
Protection functions Long-time, short-time, instantaneous and ground-fault (LSIG)
Integrated ground-fault protection Yes
Current type AC
Installation Fixed
Main-circuit terminals Rear horizontal (HR)
Auxiliary contacts 4
Open/closed position indication Yes
EAN 8015644747695
Product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070919R1?

The ABB 1SDA070919R1 is a SACE Emax 2 E2.2H 800 Ekip Hi-Touch LSIG 3p F HR air circuit breaker rated at 800 A, with three-pole fixed construction, rear horizontal terminals and an Ekip Hi-Touch LSIG electronic trip unit.

What is the rated current of the ABB E2.2H 800 Ekip Hi-Touch LSIG?

The breaker has a rated current of 800 A and is designed for demanding low-voltage electrical distribution applications.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG trip unit provides long-time overload protection (L), short-time short-circuit protection (S), instantaneous short-circuit protection (I) and ground-fault protection (G).

What is the breaking capacity of the ABB 1SDA070919R1?

The E2.2H 800 provides a rated ultimate short-circuit breaking capacity of 100 kA at 440 V AC and a rated short-time withstand current of 85 kA for 1 s.

What does F HR mean on the ABB E2.2H 800?

The F HR designation identifies a fixed-version breaker with rear horizontal terminals, providing a rear connection arrangement for integration into compatible low-voltage switchboards.

Is the ABB E2.2H 800 1SDA070919R1 fixed or withdrawable?

The 1SDA070919R1 is a fixed-version air circuit breaker, intended for permanent installation within a compatible low-voltage switchboard or distribution assembly.

Does the ABB 1SDA070919R1 include ground-fault protection?

Yes. The Ekip Hi-Touch LSIG trip unit includes ground-fault protection in addition to long-time, short-time and instantaneous overcurrent protection.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are engineered for reliable protection, switching and management of low-voltage electrical distribution systems, supporting demanding industrial, commercial and infrastructure installations.