1SDA070873R1 ABB E1.2C 1600 Ekip Dip LSIG 3p F F Air Circuit Breaker

1SDA070873R1 ABB E1.2C 1600 Ekip Dip LSIG 3p F F Air Circuit Breaker

ABB 1SDA070873R1 Emax 2 E1.2C 1600 fixed three-pole air circuit breaker with Ekip Dip LSIG electronic protection, 1600 A rated current, 690 V AC operational voltage and 50 kA breaking capacity at 400/415 V AC.

SKU: 1SDA070873R1MPN: 1SDA070873R1
Price
List Price £6,420.13 ex VAT
Your Price (ex VAT) Save 25%
£4,815.10 25% OFF
You save £1,605.03 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,815.10
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,815.10

Why Choose the ABB E1.2C 1600 Ekip Dip LSIG 3p F F Air Circuit Breaker?

The ABB 1SDA070873R1, designated E1.2C 1600 Ekip Dip LSIG 3p F F, is a high-performance three-pole air circuit breaker (ACB) designed for protection and control in low-voltage power distribution systems. As part of the advanced ABB SACE Emax 2 series, it combines a 1600 A current rating with the Ekip Dip LSIG electronic trip unit for comprehensive overload, short-circuit and earth-fault protection.

The E1.2C is designed for demanding electrical distribution applications where high breaking performance, selectivity and dependable circuit protection are essential. Its Ekip Dip LSIG protection release provides long-time overload (L), short-time selective short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection, with settings configured using DIP switches.

With a rated uninterrupted current of 1600 A, rated operational voltage up to 690 V AC and rated ultimate short-circuit breaking capacity of 50 kA at 400/415 V AC, the 1SDA070873R1 is suited to main distribution boards, industrial switchboards and other critical low-voltage installations. This version is a fixed, three-pole breaker with front terminals.

Key Advantages

  • High-performance ABB SACE Emax 2 air circuit breaker for low-voltage power distribution.
  • 1600 A rated uninterrupted current for high-current electrical installations.
  • 50 kA Icu at 400/415 V AC provides robust short-circuit protection.
  • Ekip Dip LSIG electronic trip unit provides overload, selective short-circuit, instantaneous and earth-fault protection.
  • Adjustable protection settings allow coordination with downstream protection devices.
  • Fixed three-pole construction with front terminals for switchboard installation.

Key Features

  • ABB SACE Emax 2 E1.2C series.
  • 1600 A rated uninterrupted current (Iu).
  • Three-pole configuration.
  • 690 V AC rated operational voltage.
  • 1000 V AC rated insulation voltage (Ui).
  • 50 kA rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC.
  • Ekip Dip LSIG electronic protection release.
  • Adjustable overload protection from 640–1600 A.
  • Adjustable short-time delayed short-circuit protection from 960–16000 A.
  • Adjustable instantaneous short-circuit protection from 2400–24000 A.
  • Integrated earth-fault protection.
  • Fixed installation with front terminals.
  • Motor operator available as an optional accessory.

Reliable Protection for Low-Voltage Power Distribution

Air circuit breakers such as the ABB SACE Emax 2 E1.2C protect high-current low-voltage distribution systems against overloads and short circuits while providing controlled switching and isolation of electrical circuits. Their adjustable electronic protection functions enable coordination and selectivity across complex electrical distribution networks.

The Ekip Dip LSIG trip unit provides four key protection functions: long-time overload protection, short-time selective short-circuit protection, instantaneous short-circuit protection and earth-fault protection. Adjustable settings enable the breaker to be configured to suit the characteristics and protection requirements of the installation.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and switchgear assemblies.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • Generator and transformer distribution systems.
  • High-current feeder protection.
  • Industrial power distribution and control systems.

Technical Specifications

Series SACE Emax 2
Order code / MPN 1SDA070873R1
Product type Air circuit breaker (ACB)
Frame E1.2C
Rated uninterrupted current (Iu) 1600 A
Rated operational voltage (Ue) up to 690 V AC
Rated insulation voltage (Ui) 1000 V AC
Frequency 50 / 60 Hz
Number of poles 3
Installation Fixed
Terminal configuration Front terminals
Trip unit Ekip Dip LSIG
Protection functions L, S, I, G
Overload release setting 640–1600 A
Short-time delayed short-circuit setting 960–16000 A
Instantaneous short-circuit setting 2400–24000 A
Rated ultimate short-circuit breaking capacity (Icu) at 380 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 400/415 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC 50 kA
Rated ultimate short-circuit breaking capacity (Icu) at 500/525 V AC 42 kA
Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC 42 kA
Earth-fault protection Integrated
Motor operator Optional
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA070873R1 used for?

The ABB 1SDA070873R1 is an Emax 2 air circuit breaker designed for switching and protecting high-current low-voltage electrical distribution systems against overloads, short circuits and earth faults.

What is the current rating of the ABB E1.2C 1600?

The breaker has a rated uninterrupted current of 1600 A, with its overload protection adjustable from 640–1600 A.

What does Ekip Dip LSIG mean?

The Ekip Dip LSIG electronic trip unit provides long-time overload (L), short-time short-circuit (S), instantaneous short-circuit (I) and earth-fault (G) protection.

What is the breaking capacity of the 1SDA070873R1?

The E1.2C 1600 has a rated ultimate short-circuit breaking capacity (Icu) of 50 kA at 400/415 V AC.

Is the ABB 1SDA070873R1 a fixed or withdrawable circuit breaker?

This version is a fixed three-pole air circuit breaker with front terminals, designed for permanent installation within a suitable low-voltage switchboard or switchgear assembly.

Trusted Low-Voltage Protection from ABB