Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA070840R1 is a SACE Emax 2 E1.2C 1250 A three-pole fixed air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator and low-voltage power distribution protection.
£7,734.26
The ABB 1SDA070840R1 is a high-performance SACE Emax 2 E1.2C air circuit breaker (ACB) designed for advanced generator protection and low-voltage power distribution. Rated at 1250 A, this three-pole breaker incorporates an Ekip G Hi-Touch LSIG electronic trip unit providing long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection.
The Ekip G Hi-Touch release combines generator-oriented protection with advanced measurement, monitoring and touchscreen functionality. Its enhanced electronic platform supports sophisticated protection coordination and access to operating information, making the breaker particularly suitable for generator-fed networks, critical distribution systems and intelligent switchboards.
This configuration is a three-pole fixed air circuit breaker with front terminals. The E1.2C performance level provides an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC, together with a short-time withstand current of 42 kA for 1 second.
Generator-fed electrical systems require sophisticated protection capable of responding to overloads, short circuits and earth faults while supporting effective coordination with other protective devices. The Ekip G Hi-Touch LSIG platform combines generator-oriented protection with advanced measurement and monitoring functions within the ABB SACE Emax 2 architecture.
The LSIG protection package covers overload, delayed short-circuit, instantaneous short-circuit and earth-fault conditions. Combined with the E1.2C frame's 50 kA breaking capability at 400–440 V AC and 42 kA one-second withstand rating, the 1SDA070840R1 provides a robust solution for generator switchboards and critical low-voltage distribution systems.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA070840R1 |
| EAN / GTIN | 8015644746902 |
| Product type | Air circuit breaker |
| Frame | E1.2C |
| Short-circuit performance level | C |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Number of poles | 3 |
| Current type | AC |
| Installation | Fixed |
| Terminal arrangement | Front terminals |
| Main-circuit connection | Bolted connection |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Electronic |
| Protection functions | L (long-time overload), S (short-time short circuit), I (instantaneous short circuit), G (earth fault) |
| Ultimate short-circuit breaking capacity (Icu) at 400 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 42 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Service short-circuit breaking capacity (Ics) at 400–440 V AC | 50 kA |
| Service short-circuit breaking capacity (Ics) at 500–690 V AC | 42 kA |
| Service breaking capacity | 100% of Icu |
| Short-time withstand current (Icw), 1 s | 42 kA |
| Short-time withstand current (Icw), 3 s | 24 kA |
| Auxiliary contacts | 4 change-over contacts |
| Power loss | 122 W |
| Electrical durability at Ue ≤ 440 V | 8000 cycles |
| Electrical durability at Ue 500–690 V | 6500 cycles |
| Mechanical durability | 20000 cycles |
| Dimensions (W × H × D) | 210 × 296 × 183 mm |
| Net weight | 14 kg |
| Standard | IEC 60947-2 |
| ABB product group | Emax2 Air Circuit Breaker |
The ABB 1SDA070840R1 is a SACE Emax 2 E1.2C 1250 A three-pole fixed air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG electronic trip unit for advanced generator and power distribution protection.
The Ekip G Hi-Touch LSIG provides long-time overload, short-time short-circuit, instantaneous short-circuit and earth-fault protection, together with advanced generator-oriented measurement, monitoring and touchscreen functionality.
The E1.2C 1250 provides an ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC.
The 1SDA070840R1 is a fixed three-pole air circuit breaker with front terminals.
It is particularly suited to generator switchboards, industrial power systems, main low-voltage distribution boards, critical power installations and infrastructure systems requiring advanced generator-oriented LSIG protection.
ABB SACE Emax 2 air circuit breakers combine dependable switching performance, advanced electronic protection and sophisticated generator-oriented monitoring for demanding low-voltage power distribution applications.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.