Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA070800R1 E1.2C is a 1000 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals, an Ekip G Hi-Touch LSIG electronic trip unit and up to 50 kA breaking capacity for advanced generator and low-voltage power distribution protection.
£7,508.55
The ABB E1.2C 1000 Ekip G Hi-Touch LSIG 3P F F (1SDA070800R1) is a high-performance three-pole fixed air circuit breaker (ACB) from the ABB SACE Emax 2 range. Designed for demanding low-voltage AC power distribution and generator applications, it combines a rated uninterrupted current of 1000 A with the compact E1.2 frame and the advanced Ekip G Hi-Touch electronic protection platform.
The integrated Ekip G Hi-Touch LSIG solid-state trip unit provides long-time, short-time, instantaneous and ground-fault protection. Its generator-oriented protection capabilities and advanced measurement functionality make this configuration particularly suitable for installations where comprehensive electrical protection, monitoring and power management are required.
The E1.2C performance level provides a rated ultimate short-circuit breaking capacity of 50 kA at common low-voltage distribution levels, together with a rated short-time withstand current of 42 kA for 1 s. Supplied as a fixed three-pole breaker with front terminals, the 1SDA070800R1 includes four auxiliary contacts and circuit breaker open/closed position indication for effective switchboard integration.
The Ekip G Hi-Touch LSIG release combines advanced generator-oriented protection with comprehensive electronic circuit protection. Long-time protection responds to sustained overloads, short-time protection enables controlled response to elevated fault currents, instantaneous protection provides rapid interruption of severe short circuits, and ground-fault protection detects potentially damaging earth-fault currents.
Combined with the E1.2C breaker's 50 kA breaking capability at 400–440 V AC and 42 kA 1-second short-time withstand rating, the Ekip G Hi-Touch LSIG configuration provides a sophisticated protection platform for generator switchboards and critical power distribution systems. The fixed construction and front terminals provide a compact arrangement for permanent integration into compatible low-voltage switchgear.
| Series | SACE Emax 2 |
|---|---|
| Order code | 1SDA070800R1 |
| EAN | 8015644746506 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Frame | E1.2 |
| Performance level | C |
| Rated uninterrupted current (Iu) | 1000 A |
| Number of poles | 3 |
| Current type | AC |
| Trip unit | Ekip G Hi-Touch LSIG |
| Release type | Solid-state electronic |
| Protection functions | L, S, I, G |
| Long-time protection | Overload protection |
| Short-time protection | Delayed short-circuit protection |
| Instantaneous protection | Instantaneous short-circuit protection |
| Ground-fault protection | Integrated |
| Rated operational voltage | up to 690 V AC |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–440 V AC | 50 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–690 V AC | 42 kA |
| Rated short-time withstand current (Icw), 1 s | 42 kA |
| Mounting type | Fixed |
| Terminal configuration | Front terminals |
| Main circuit connection | Bolt connection |
| Auxiliary contacts | 4 |
| Circuit breaker position indication | Open / closed |
| Mechanical durability | 20,000 operating cycles |
| Electrical durability | 8,000 operating cycles |
| Product width | 214 mm |
| Product height | 295 mm |
| Product depth | 184 mm |
| Product net weight | 11 kg |
| Package width | 270 mm |
| Package height | 350 mm |
| Package depth | 330 mm |
| Package gross weight | 16 kg |
| Minimum order quantity | 1 piece |
| Customs tariff number | 85362090 |
| Standard | IEC 60947-2 |
The ABB 1SDA070800R1 is an E1.2C 1000 A three-pole fixed SACE Emax 2 air circuit breaker with front terminals and an Ekip G Hi-Touch LSIG solid-state electronic trip unit.
The Ekip G Hi-Touch LSIG trip unit provides long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection, together with advanced functionality intended for demanding generator and power distribution applications.
The ABB E1.2C in this configuration has a rated uninterrupted current of 1000 A.
The E1.2C has a rated ultimate short-circuit breaking capacity of 50 kA at 400–440 V AC and 42 kA at 500–690 V AC.
The ABB 1SDA070800R1 is a fixed three-pole air circuit breaker with front terminals, designed for permanent installation within a compatible low-voltage or generator switchboard.
ABB SACE Emax 2 air circuit breakers combine advanced electronic protection, generator-oriented functionality, high short-circuit performance and compact switchgear design to provide dependable protection and power management for industrial, commercial, infrastructure and critical power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.