Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA070782R1 is a SACE Emax 2 E1.2B three-pole fixed 1000 A air circuit breaker rated at 690 V AC with front terminals, an Ekip Dip LSI electronic trip unit and a 42 kA ultimate breaking capacity at 400–690 V AC.
£3,852.07
The ABB 1SDA070782R1, designated E1.2B 1000 Ekip Dip LSI 3p F F, is a high-performance SACE Emax 2 air circuit breaker (ACB) designed for protection and switching in low-voltage AC power distribution systems. Part of the ABB SACE Emax 2 E1.2 series, this fixed three-pole circuit breaker combines a 1000 A rated uninterrupted current with the reliable Ekip Dip LSI electronic trip unit.
The Ekip Dip LSI release provides long-time overload, short-time short-circuit and instantaneous short-circuit protection. Adjustable protection thresholds allow the breaker to be configured using DIP switches, providing a straightforward and dependable method of adapting protection characteristics to the requirements of the electrical installation.
With a rated operational voltage of up to 690 V AC and a B short-circuit performance level, the E1.2B 1000 provides a rated ultimate short-circuit breaking capacity of 42 kA at 400–690 V AC. Its compact E1.2 frame, fixed construction and front terminal arrangement make it suitable for industrial, commercial and infrastructure switchboards requiring reliable high-current circuit protection.
The Ekip Dip LSI electronic trip unit provides three essential protection functions for low-voltage distribution systems. Long-time protection responds to sustained overload conditions, short-time protection allows selective coordination during short-circuit events, and instantaneous protection provides rapid interruption when severe fault currents occur.
Combined with the ABB SACE Emax 2 platform, the Ekip Dip release provides dependable electronic protection with straightforward DIP-switch configuration. The 1SDA070782R1 also offers a 42 kA short-time withstand capability for 1 s, supporting selective protection strategies in switchboards where downstream protective devices should be given an opportunity to clear faults before the main breaker operates.
| Series | SACE Emax 2 |
|---|---|
| Frame | E1.2 |
| Order code / Product ID | 1SDA070782R1 |
| Product group | Emax2 Air Circuit Breaker |
| Product type | Air circuit breaker |
| Execution | Fixed |
| Number of poles | 3 |
| Rated current (In) | 1000 A |
| Rated uninterrupted current (Iu) | 1000 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V AC |
| Rated impulse withstand voltage (Uimp) | 12 kV |
| Frequency | 50 / 60 Hz |
| Trip unit | Ekip Dip LSI |
| Release type | Electronic |
| Protection functions | LSI |
| Overload protection setting | 0.4–1 × In |
| Short-time protection setting | 0.6–10 × In |
| Instantaneous protection setting | 1.5–15 × In |
| Short-circuit performance level | B |
| Rated ultimate short-circuit breaking capacity (Icu) at 400–415 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 440 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 42 kA |
| Rated ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Rated service short-circuit breaking capacity (Ics) | 42 kA |
| Ics as percentage of Icu | 100% |
| Rated short-time withstand current (Icw) | 42 kA for 1 s; 24 kA for 3 s |
| Terminal connection type | Front |
| Terminal type | Bolt |
| Main circuit screw | M10 |
| Tightening torque | 45 N·m |
| Power loss | 78 W |
| Electrical durability | 8000 cycles |
| Mechanical durability | 20000 cycles |
| Suitable for IT networks | Yes, up to 690 V |
| Dimensions (W × H × D) | 210 × 296 × 183 mm |
| Net weight | 14 kg |
| EAN | 8015644746322 |
| Standard | IEC |
The ABB 1SDA070782R1 is an Emax 2 air circuit breaker designed for switching and protecting low-voltage AC distribution systems, including transformer, generator and installation protection applications.
The 1SDA070782R1 has a rated uninterrupted current of 1000 A.
The breaker uses an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection with DIP-switch-adjustable settings.
The E1.2B 1000 has a rated ultimate short-circuit breaking capacity of 42 kA at 400–690 V AC, with a rated service breaking capacity equal to 100% of Icu.
The 1SDA070782R1 is a three-pole fixed air circuit breaker with front bolted terminal connections.
ABB SACE Emax 2 air circuit breakers combine high-performance fault interruption with configurable Ekip electronic protection for dependable industrial, commercial and infrastructure low-voltage power distribution systems.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.