1SDA070769R1 ABB E1.2N 800 Ekip Hi-Touch LSIG 3-Pole Fixed Air Circuit Breaker

1SDA070769R1 ABB E1.2N 800 Ekip Hi-Touch LSIG 3-Pole Fixed Air Circuit Breaker

ABB 1SDA070769R1 is an Emax 2 E1.2N 800 A three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSIG solid-state electronic trip unit for advanced overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.

SKU: 1SDA070769R1MPN: 1SDA070769R1
Price
List Price £10,171.89 ex VAT
Your Price (ex VAT) Save 25%
£7,628.92 25% OFF
You save £2,542.97 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £7,628.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£7,628.92

Why Choose the ABB 1SDA070769R1 E1.2N 800 Ekip Hi-Touch LSIG Air Circuit Breaker?

The ABB 1SDA070769R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker equipped with an advanced Ekip Hi-Touch LSIG solid-state electronic trip unit. Designed for demanding low-voltage AC power-distribution systems, it combines an 800 A rated uninterrupted current with comprehensive electronic protection, measurement and monitoring capabilities.

This configuration features front terminals and the E1.2N short-circuit performance level, providing an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated short-time withstand current is 50 kA for 1 second and 30 kA for 3 seconds, supporting robust operation in high-performance distribution systems.

The Ekip Hi-Touch LSIG release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection. The breaker is also fitted with four auxiliary change-over contacts and open/closed position indication, supporting integration into professional switchboard control, automation and monitoring systems.

Key Advantages

  • Advanced ABB SACE Emax 2 air circuit breaker for demanding low-voltage distribution.
  • 800 A rated uninterrupted current in the compact E1.2 frame.
  • Ekip Hi-Touch LSIG electronic trip unit with comprehensive protection and monitoring functionality.
  • 66 kA ultimate short-circuit breaking capacity at 400–440 V AC.
  • 50 kA short-time withstand current for 1 second.
  • Three-pole fixed construction with front terminals for professional switchboard integration.

Key Features

  • ABB SACE Emax 2 air circuit breaker.
  • E1.2N 800 configuration.
  • 800 A rated uninterrupted current.
  • 690 V AC rated operational voltage.
  • Three-pole construction.
  • Fixed execution.
  • Front terminals.
  • Ekip Hi-Touch LSIG solid-state electronic trip unit.
  • LSIG protection: long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
  • Fitted with four auxiliary change-over contacts and circuit-breaker open/closed position indication.

Advanced LSIG Protection and Power-System Supervision

The Ekip Hi-Touch LSIG electronic trip unit provides comprehensive protection for sophisticated low-voltage distribution systems. Long-time protection responds to sustained overloads, selective short-circuit protection supports coordinated fault clearing, instantaneous protection rapidly responds to severe short circuits, and integrated earth-fault protection provides additional protection against ground-fault conditions.

Combined with the E1.2N air circuit-breaker platform, the ABB 1SDA070769R1 delivers high fault-interruption capability in a compact fixed configuration. Front terminals facilitate switchboard connection, while the Hi-Touch platform and auxiliary contacts support advanced protection, electrical supervision, automation and status monitoring.

Typical Applications

  • Low-voltage main distribution switchboards.
  • Industrial power-distribution systems.
  • Commercial building electrical distribution.
  • Transformer, generator and installation protection.
  • Critical power and infrastructure installations.
  • OEM switchboards requiring advanced LSIG protection and electrical supervision.

Technical Specifications

Product family SACE Emax 2
ABB order code 1SDA070769R1
Product type Air circuit breaker
Frame E1.2
Short-circuit performance level N
Rated uninterrupted current 800 A
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V AC
Rated impulse withstand voltage 12 kV
Number of poles 3
Execution Fixed
Terminal connection Front
Trip unit Ekip Hi-Touch LSIG
Release technology Solid-state electronic
Protection functions LSIG
Integrated earth-fault protection Yes
Ultimate short-circuit breaking capacity at 400 V AC 66 kA
Ultimate short-circuit breaking capacity at 415 V AC 66 kA
Ultimate short-circuit breaking capacity at 440 V AC 66 kA
Ultimate short-circuit breaking capacity at 500 V AC 50 kA
Ultimate short-circuit breaking capacity at 690 V AC 50 kA
Rated service short-circuit breaking capacity 50 kA
Short-time withstand current, 1 s 50 kA
Short-time withstand current, 3 s 30 kA
Auxiliary contacts 4 change-over contacts
Circuit-breaker position indication Open / closed
Degree of protection IP30
Product net dimensions (W × H × D) 210 × 296 × 183 mm
Product net weight 14 kg
Standard IEC
EAN 8015644746193
ABB product group Emax2 Air Circuit Breaker

Frequently Asked Questions

What is the ABB 1SDA070769R1?

The ABB 1SDA070769R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSIG solid-state electronic trip unit.

What is the current rating of ABB 1SDA070769R1?

The E1.2N 800 configuration has a rated uninterrupted current of 800 A.

What protection functions does the Ekip Hi-Touch LSIG trip unit provide?

The LSIG configuration provides long-time overload protection, selective short-circuit protection, instantaneous short-circuit protection and integrated earth-fault protection.

What is the breaking capacity of the E1.2N 800?

The E1.2N 800 provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.

What is the short-time withstand current of ABB 1SDA070769R1?

The circuit breaker has a rated short-time withstand current of 50 kA for 1 second and 30 kA for 3 seconds.

Does ABB 1SDA070769R1 provide earth-fault protection?

Yes. The Ekip Hi-Touch LSIG trip unit includes integrated earth-fault protection as part of its LSIG protection functions.

Is ABB 1SDA070769R1 fixed or withdrawable?

The ABB 1SDA070769R1 is a fixed Emax 2 air circuit breaker with front terminals.

Does ABB 1SDA070769R1 include auxiliary contacts?

Yes. This configuration is fitted with four auxiliary change-over contacts and circuit-breaker open/closed position indication.

Trusted by Electrical Professionals Worldwide

ABB SACE Emax 2 air circuit breakers are used in demanding industrial, commercial and infrastructure power systems where dependable fault protection, selective coordination, advanced electronic functionality and robust low-voltage switching performance are essential.