ABB 1SDA070769R1 is an Emax 2 E1.2N 800 A three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSIG solid-state electronic trip unit for advanced overload, selective short-circuit, instantaneous short-circuit and earth-fault protection.
£7,628.92
The ABB 1SDA070769R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker equipped with an advanced Ekip Hi-Touch LSIG solid-state electronic trip unit. Designed for demanding low-voltage AC power-distribution systems, it combines an 800 A rated uninterrupted current with comprehensive electronic protection, measurement and monitoring capabilities.
This configuration features front terminals and the E1.2N short-circuit performance level, providing an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC. Its rated short-time withstand current is 50 kA for 1 second and 30 kA for 3 seconds, supporting robust operation in high-performance distribution systems.
The Ekip Hi-Touch LSIG release provides long-time overload, selective short-circuit, instantaneous short-circuit and earth-fault protection. The breaker is also fitted with four auxiliary change-over contacts and open/closed position indication, supporting integration into professional switchboard control, automation and monitoring systems.
The Ekip Hi-Touch LSIG electronic trip unit provides comprehensive protection for sophisticated low-voltage distribution systems. Long-time protection responds to sustained overloads, selective short-circuit protection supports coordinated fault clearing, instantaneous protection rapidly responds to severe short circuits, and integrated earth-fault protection provides additional protection against ground-fault conditions.
Combined with the E1.2N air circuit-breaker platform, the ABB 1SDA070769R1 delivers high fault-interruption capability in a compact fixed configuration. Front terminals facilitate switchboard connection, while the Hi-Touch platform and auxiliary contacts support advanced protection, electrical supervision, automation and status monitoring.
| Product family | SACE Emax 2 |
|---|---|
| ABB order code | 1SDA070769R1 |
| Product type | Air circuit breaker |
| Frame | E1.2 |
| Short-circuit performance level | N |
| Rated uninterrupted current | 800 A |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage | 1000 V AC |
| Rated impulse withstand voltage | 12 kV |
| Number of poles | 3 |
| Execution | Fixed |
| Terminal connection | Front |
| Trip unit | Ekip Hi-Touch LSIG |
| Release technology | Solid-state electronic |
| Protection functions | LSIG |
| Integrated earth-fault protection | Yes |
| Ultimate short-circuit breaking capacity at 400 V AC | 66 kA |
| Ultimate short-circuit breaking capacity at 415 V AC | 66 kA |
| Ultimate short-circuit breaking capacity at 440 V AC | 66 kA |
| Ultimate short-circuit breaking capacity at 500 V AC | 50 kA |
| Ultimate short-circuit breaking capacity at 690 V AC | 50 kA |
| Rated service short-circuit breaking capacity | 50 kA |
| Short-time withstand current, 1 s | 50 kA |
| Short-time withstand current, 3 s | 30 kA |
| Auxiliary contacts | 4 change-over contacts |
| Circuit-breaker position indication | Open / closed |
| Degree of protection | IP30 |
| Product net dimensions (W × H × D) | 210 × 296 × 183 mm |
| Product net weight | 14 kg |
| Standard | IEC |
| EAN | 8015644746193 |
| ABB product group | Emax2 Air Circuit Breaker |
The ABB 1SDA070769R1 is a SACE Emax 2 E1.2N 800 three-pole fixed air circuit breaker with front terminals and an Ekip Hi-Touch LSIG solid-state electronic trip unit.
The E1.2N 800 configuration has a rated uninterrupted current of 800 A.
The LSIG configuration provides long-time overload protection, selective short-circuit protection, instantaneous short-circuit protection and integrated earth-fault protection.
The E1.2N 800 provides an ultimate short-circuit breaking capacity of 66 kA at 400–440 V AC and 50 kA at 500–690 V AC.
The circuit breaker has a rated short-time withstand current of 50 kA for 1 second and 30 kA for 3 seconds.
Yes. The Ekip Hi-Touch LSIG trip unit includes integrated earth-fault protection as part of its LSIG protection functions.
The ABB 1SDA070769R1 is a fixed Emax 2 air circuit breaker with front terminals.
Yes. This configuration is fitted with four auxiliary change-over contacts and circuit-breaker open/closed position indication.
ABB SACE Emax 2 air circuit breakers are used in demanding industrial, commercial and infrastructure power systems where dependable fault protection, selective coordination, advanced electronic functionality and robust low-voltage switching performance are essential.